Compact high-sensitivity spectrofluorometer; FS5 v2 is adaptable to a wide range of research and analytical applications. High Sensitivity: Photon counting detection, with a signal-to-noise ratio of 12,000:1, provides exceptional sensitivity for the detection of weak fluorescence signals 2-in-1 Spectrometer: Measure both absorption and fluorescence spectra in a single instrument Adaptable: Tailor to your requirements, from a dedicated spectral fluorometer to an all-in-one characterisation platform with time-resolved fluorescence and quantum yield Plug & Play Sample Modules: Auto-recognised sample modules that can be swapped in seconds, enabling a rapid transition between different sample formats and measurement types Near-Infrared Detection: Extend the measurement range out to 2050 nm by adding a NIR detector, ideal for studying NIR-emitters, such as quantum dots and upconversion nanoparticles Automated Acquisition: Maximise your lab productivity with the FluoAuto software feature to create automated sample measurement sequences The FS5 Spectrofluorometer is a compact, high-performance benchtop system designed for the comprehensive characterisation of fluorescent and phosphorescent samples. Since its launch in 2013, the FS5 series has become a trusted solution for fluorescence research, contributing to thousands of scientific publications worldwide. The FS5 v2 Spectrofluorometer is the latest evolution of the FS5, offering enhanced performance and expanded capabilities to meet the growing demands of modern photoluminescence spectroscopy. Equipped with top-tier optical components, photon-counting sensitivity, and fluorescence lifetime capabilities, the FS5 excels in both rapid routine analysis and sensitive research tasks. This compact benchtop instrument adapts seamlessly to your needs, offering flexibility with multiple source and detector configurations without expanding its footprint. As standard, the FS5 v2 includes a photon-counting PMT detector for visible-range fluorescence spectra and an absorption detector. It can be easily upgraded to perform NIR measurements up to 1650 nm, time-resolved fluorescence or phosphorescence, photoluminescence quantum yields, and anisotropy. Technical Specifications: Optics - All-reflective for a wavelength independent focus with high brightness (small focus) at the sample Source - 150 W CW Ozone-free xenon arc lamp (UV-enhanced ozone generating option available) Monochromators - Czerny-Turner design with dual grating turret; plane gratings for accurate focus at all wavelength and minimum stray light Spectral Coverage - Excitation - <230 nm - 1000 nm Spectral Coverage - Emission - 200 nm - >870 nm Filter Wheels - Fully automated; included in both the excitation and emission monochromators Bandpass - Excitation/Emission - 0 to 30 nm, continuously adjustable Wavelength Accuracy - Excitation/Emission - ± 0.5 nm Scan Speed - Excitation/Emission - 100 nm/s Integration Time - 1 ms - 200 s Emission Detector - Photomultiplier, spectral coverage 200 nm - 870 nm, cooled and stabilised Reference Detector - UV enhanced silicon photodiode Transmission Detector - UV enhanced silicon photodiode Signal-to-Noise Ratio of Water Raman Signal - SNR SQRT >12,000:1* Dimensions - 104 cm (w) x 59 cm (d) x 32 cm (h) Weight - 65 kg * A minimum SNR of 12,000:1 is guaranteed. Systems with a higher sensitivity specification can be supplied on request. Standard water Raman measurement conditions: Excitation wavelength = 350 nm, Excitation and emission bandwidths = 5 nm, step size = 1 nm, integration time = 1 s, emission wavelength = 397 nm, noise measured at 450 nm and calculation based on the SQRT method

Versatile double beam UV-Vis spectrophotometer with a benchtop footprint. Suitable for analytical, research, and pharmaceutical industry applications. Variable bandpass options: 0.5, 1.0, 1.5, 2.0 or 4.0 nm over the range 190 nm – 1100 nm Fast scanning: up to 6,000 nm/min to aid sample analysis throughput Automatic accessory recognition: when connected to the DB30 Optional Visacle® software: for easy PC control Touchscreen interface: intuitive menus and functions for ease of use for standalone control Multiple Data Storage Options: USB, SD card and internal data storage for convenient retrieval of methods and results The DB30 UV-Vis Spectrophotometer is a powerful double beam instrument designed for precise and accurate measurement of absorption and transmission across various wavelengths, making it essential for analytical applications where precision is paramount. Engineered for versatility, this user-friendly spectrophotometer excels in a wide range of measurements, from standard absorbance in cuvettes to solid samples and flow cell experiments. Its high-throughput optical design delivers exceptional performance, ensuring superior stray light control, baseline stability, and unmatched wavelength and photometric accuracy. The DB30 UV-Vis Double Beam Spectrophotometer offers flexible operation, allowing users to work either independently through its integrated touchscreen or via PC control using the powerful Spectracle® software. Spectracle® features an intuitive workflow-based interface, enabling efficient data acquisition, advanced data processing, and comprehensive reporting. For laboratories operating in regulated environments, the optional Visacle® CFR software package provides 21 CFR Part 11 compliance, ensuring enhanced data security, integrity, and traceability. As standard, the DB30 comes with a touchscreen for standalone operation controlling all modes of operation: photometry, time scan, wavelength scan, and data analysis, including calibration curves. Spectracle® PC-controlled software is designed to be easy-to-use, providing powerful features and functions. Using the software’s workflow design, users can easily create, join, and process different scans for analysis and reporting purposes. Spectracle® enhances the DB30 experience by offering comprehensive control, validation, data analysis, and reporting—all in one streamlined package. Acquired data can be processed and easily exported in.txt,.csv, or PDF formats Core Features: UV Absorption Spectra - The DB30 covers the UV range down to 190 nm with an absorbance range 3. This makes measuring samples high UV absorption possible, such as the edible oil spectra plotted below. Particle Size: DB30 NanoSize package - The DB30 NanoSize package includes DB30 main unit, SpectroLink™, NanoCuvette™ S. Particle size measurement is now affordable with NanoSize package and calculations are to be done in SpectroWork™ using machine learning software. Refractive Index: DB30 NanoIndex package - The DB30 NanoIndex package includes DB30 main unit, SpectroLink™, NanoCuvette™ One. Refractive index of sugar solution can be measured easily with NanoIndex package and calculations are to be done in SpectroWork™ using machine learning software. Chromium (VI): Quantitation made easy - The DB30 features a built-in quantitation mode that simplifies concentration analysis. Standard solutions are measured, and the instrument automatically generates a calibration (standard) curve. For unknown samples, the DB30 calculates the sample concentration directly from the measured absorbance value using the established calibration curve. This enables fast, accurate, and reliable quantitation with minimal user effort. TECHNICAL SPECIFICATIONS Optics: Czerny-Turner, Dual Beam Monochromator Wavelength Range: 190 nm - 1100 nm Spectral Bandwidth: 0.5 nm, 1 nm, 1.5 nm, 2 nm and 4 nm Stray Light: ≤1% T (198 nm KCl, 340 nm) ≤0.05%T (220 nm, NaI, 340 nm, NaNO2) Wavelength Accuracy: ±0.1 nm D2 peak 656.1 nm, ± 0.25 nm entire range Wavelength Repeatability: ±0.1 nm (Max deviation), ≤0.05 nm (Standard deviation) Photometric Range: Absorbance: -3.4 to +3.4, %T: 0 to 300, Concentration: 0,000 to 9,999 Photometric Accuracy: ±0.002 Abs (0 - 0.5 Abs), ±0.004 Abs (0.5 - 1.0 Abs), ±0.008 Abs (1.0 - 2.0 Abs) ±0.3% T Photometric Reproducibility: ±0.0005 Abs (0.5 Abs), ±0.001 Abs (1.0 Abs), ±0.004 Abs (2.0 Abs) Wavelength Scan Speed: 10, 100, 200, 400, 800, 1200, 2400, 3600, 6000 nm/min RMS Noise: 0.0001 Abs (Peak-to-peak) 0.00005 Abs (RMS) Baseline Stability: <0.0003 Abs/hr (500 nm, 2 hour lamp warm-up period) Baseline Flatness: ±0.0009 Abs (200 nm - 950 nm) Light Source: Tungsten-Halogen and Deuterium Lamps Light Source Switching: Automatic switching selectable for 325 nm - 370 nm range Detector: Silicon Photodiode Display: 7” Touchscreen Software: Touchscreen operation, PC-controlled software or CFR compliant PC-controlled software Dimensions: 500 mm (W) × 475 mm (D) × 250 mm (H) Net Weight: 20 kg (approx) Power Supply: 100 - 240V, 50/60 Hz, 150VA Ambient Temperature: 10°C - 35°C Output Device: USB flash drive, SD card Interface: USB PC interface
CATEGORY

Highly modular photoluminescence spectrometer designed for ultimate sensitivity and versatility in steady-state and time-resolved photoluminescence research. The FLS1000 Photoluminescence Spectrometer redefines excellence in steady-state and time-resolved photoluminescence spectroscopy, making it the go-to choice for both advanced research and routine lab work. This modular system delivers precise measurements across a broad spectral range—from ultraviolet to mid-infrared (up to 5,500 nm)—and captures lifetimes from picoseconds to seconds. It also offers highly accurate absolute photoluminescence quantum yield measurements, with flexible upgrade options available at purchase or added later as your research grows. No matter your application, the FLS1000 enables you to measure luminescence spectra and kinetics with unmatched accuracy using cutting-edge sources, detectors, and acquisition techniques. Its spacious sample chamber accommodates nearly any sample accessory with ease. With industry-leading sensitivity of over 35,000:1 for the standard water Raman (SQRT method), this instrument excels at detecting weakly fluorescent samples. All functions are seamlessly managed by Fluoracle®, an all-in-one software package for comprehensive data acquisition and analysis. - Ultimate Sensitivity: Highest sensitivity on the market, with a signal-to-noise ratio of 35,000:1, ensures that the weakest photoluminescence signals can be detected - Modular Design: Customise the configuration to suit your specific research requirements; select from different light sources, detectors, and sample holders to create the optimal configuration - Upgradability: Upgrade your system with additional modules as new research needs arise, protecting the investment and keeping the equipment at the cutting edge of your research - NIR & MIR: Characterise NIR and MIR emitters with a wide range of infrared detector options with sensitivity out to 5500 nm - Automation: Equipped with advanced Fluoracle® software for comprehensive control of experiments, data acquisition, analysis, and time-saving automation features - Micro-Spectroscopy: Transform the FLS1000 into a powerful photoluminescence microscope with the MicroPL Upgrade; enabling high-resolution mapping of microscopic samples Live Video Demonstration: Send us your samples, and we can measure them live in an online demonstration Bespoke Development: Fully customisable systems for your requirements Faster Measurements: Increased scan speeds and leading performance Industry Leading Sensitivity: 35,000:1 Sensitivity Specification MicroPL Upgrade: For spectral and time-resolved photoluminescence microscopy Dedicated Team: Our dedicated team of applications scientists are available assist you with your samples
CATEGORY

Whilst the RMS1000 can be configured with a wide range of lasers, techniques, detectors and gratings as standard, sometimes that simply isn’t enough! Recently, we engineered a system that fully leverages its capabilities to their fullest extent. Equipped with two spectrographs to enhance resolution and functionality, the RMS1000 facilitates numerous techniques thanks to its extensive array of lasers and detectors. Internally, this system integrates 4 CW diode lasers for Raman and photoluminescence (PL) measurements. In response to the customer’s existing EI pulsed lasers (EPL, HPL, and VPL series), the microscope was modified to seamlessly integrate filter cubes. This adjustment relieves pressure on the six-position filter turret, enabling unrestricted use of EPL/HPL/VPL lasers, and allowing additional external lasers to be coupled. The system includes two IR lasers for upconversion measurements, alongside a Ti:Sapphire laser coupled into the external port, offering shared compatibility with their FLS1000, shown in the image below. To accommodate these diverse laser sources, the instrument houses 4 detectors: EMCCD, InGaAs, PMT, and NIR-PMT. Despite its complexity, Ramacle software efficiently manages and operates all internal components, ensuring user-friendly control while expanding capabilities to support a wide range of techniques—a true Multimodal RMS1000! Techniques: Raman, PL, FLIM, Upconversion
CATEGORY

Whilst the RMS1000 can be configured with a wide range of lasers, techniques, detectors and gratings as standard, sometimes that simply isn’t enough! Recently, we engineered a system that fully leverages its capabilities to their fullest extent. Equipped with two spectrographs to enhance resolution and functionality, the RMS1000 facilitates numerous techniques thanks to its extensive array of lasers and detectors. Internally, this system integrates 4 CW diode lasers for Raman and photoluminescence (PL) measurements. In response to the customer’s existing EI pulsed lasers (EPL, HPL, and VPL series), the microscope was modified to seamlessly integrate filter cubes. This adjustment relieves pressure on the six-position filter turret, enabling unrestricted use of EPL/HPL/VPL lasers, and allowing additional external lasers to be coupled. The system includes two IR lasers for upconversion measurements, alongside a Ti:Sapphire laser coupled into the external port, offering shared compatibility with their FLS1000, shown in the image below. To accommodate these diverse laser sources, the instrument houses 4 detectors: EMCCD, InGaAs, PMT, and NIR-PMT. Despite its complexity, Ramacle software efficiently manages and operates all internal components, ensuring user-friendly control while expanding capabilities to support a wide range of techniques—a true Multimodal RMS1000! Techniques: Raman, PL, FLIM, Upconversion
CATEGORY