NW
Consumables
ConsumablesInstrumentation

PhyMetrix Mini-Demister

By PhyMetrix Inc

Proudly Designed, Developed and Manufactured in the USA Ideal for SF6 or NG moisture measurement Increases Accuracy, Reliability & Sensor Life Enhances speed of response Sized perfectly for Portable Analyzers Ease of Service & Maintenance Unique State-of-the-art Features Test Measure Calibrate Quick Reproducible NIST Traceable - Liquid knock-out, separates liquids from gasses - Liquids visible before compromising analyzer - Convenient rotatable drain valve and tube - Works with any portable gas analyzer - Seal integrity for even the most demanding measurement of trace moisture - Stainless steel construction with Viton seals - High Pressure Glass tube (425 psi rating) - Protective plastic shield - Optional internal flow control orifice - Variety of available fittings swageable, SAE, NPT - Superior to coalescing filters: no absorbent materials - no future out-gassing You will Save Time & Money while achieving optimum performance with your gas analyzer. Technical Specifications ORDERING INFORMATION Part Number PhyMetrix Mini-Demister MD Included: Inlet Fitting (specify type), Outlet Orifice (specify nominal sample pressure) Doc. Revision 1 Installation and Connection Details Temperature Range Mechanical Pressure Pyrex Glass Tube maximum recommended working pressure: 425 psi up to 150˚F and 315 psi up to 425˚F Valve maximum inlet pressure: 300 psi Miscellaneous Features -20˚C to +60˚C 1/8" NPTF Inlet, 5/16"-24 SAE straight thread Outlet All 316 Stainless Steel and Pyrex Glass wetted parts, Viton seals small surface area stainless steel sampling chamber for fast response time. Dimensions- L: 3.6" (91.4mm) Dia: 1" (25.4mm) Weight Total: 0.5 Lbs (1.1 Kg) Built in serviceable/cleanable 100 micron Filter The outlet to the analyzer has a built-in facility for a removable flow control pressure drop orifice. Operates by allowing liquids to settle to the bottom of the separator under force of gravity, where they are drained out through a metering valve. The sample travels through the container tube at a low velocity; thus minimizing the entrainment of any liquid droplets in the gas as it exits near the top of the separator and flows down into the analyzer. The glass container tube affords the operator a 360˚ view of the accumulated liquid. Adjusting the drain metering valve optimizes the liquid removal with minimum waste of sample gas. - Axial in-line construction; conveniently positioned INLET on top and OUTLET to analyzer on the bottom. - On the side the rotatable drain valve and port can be positioned as needed. - Stainless Steel housing, Viton seals and a glass container tube provide the seal integrity necessary even for the most demanding measurements such as low levels of moisture. - Outer impact resistant protective clear plastic shield that prevents nicks and scratches in the field. - A variety of inlet and outlet port fitting types are available, e.g. NPT, SAE straight-thread with o-ring seals, swageable tube etc. Interchangeable Inlet Fitting (Swagelok, etc.) Knurled Assembly Nut Protective Plastic Shield Glass container tube Rotatable Outlet Hub 1" dia. SAE 5/16"-24 Outlet Fitting (other options available) Drain Metering Valve 9/16" hex Repositionable 1/8" barb Drain Tube Fitting (other options available) 360˚ Viewable Separation Chamber for liquid collection Metering Valve Lock Nut Sealing Ring 1/8" NPTF port Removable Outlet flow control orifice Chamber Outlet (gas to analyzer) Chamber Inlet Chamber Drain 1.95" max open valve 3.31" ~ 0.9" for 1/8" Swagelok

More from PhyMetrix Inc

Phymetrix Explosion-Proof Moisture Probe Model: ExMa-Probe

Phymetrix Explosion-Proof Moisture Probe Model: ExMa-Probe In-situ measurement without exhausting any of the sample gas Can be inserted into pressurized pipeline through 1/2" or larger ball valve Customized insertion lengths field adjustable Unique State of the Art Features; Menu-driven, intuitive, easy-to-use Natural Gas Dew Point Meter - -110°C to +20°C dewpoint Sensor - Fast, Accurate and Repeatable Moisture Meter - Built-in temperature compensation - optional built-in pressure sensor with compensation - optional 4/20 mA sink or source output - optional RS-485 Modbus interface - 3" viewport, NEMA 4X/IP67 & Explosion-proof - State-of-the-art electronics & software - Advanced User-friendly Interface - Continuous Status and Diagnostics display - On-screen histogram and trend graph - Programmable data logging, clock calendar - Virtual Analyzer PC s/w for training & evaluation - 316 Stainless Steel & PTFE wetted parts - NIST calibrations - Cost Effective Complete In-Situ System - Thru-the-Glass Touch User Buttons - Approved Explosion-Proof Installations USA, Canada, ATEX - Installation Indoor/Outdoor On-The-Pipe or Panel Technical Specifications natural gas dew point meter Sensor - Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) - Accuracy: ±2°C temperature corrected - Repeatability: 0.8°C - Response time: 95% of step change in 3 min. - Sample flow:1 LPM Temperature Sensor - Range: -40°C to +70°C; Accuracy: ±2°C Pressure Sensor - 2 to 1000 PSIA ±1%, 316L stainless steel wetted parts (higher pressure ranges available) Electrical - 3 automatic detection – self configuring power modes: 1) 90-260VAC 47-440Hz 2) 12-24VDC 10VA 3) Optional 4/20mA Loop Powered - Power modes 1 or 2 have the following I/O options: a) RS-485 isolated Modbus® interface b) Analog Output 4/20mA sink or source isolated with HART® c) up to 3 Alarm Relays – 3A, 250VAC contacts Mechanical - Enclosure - Aluminum or optional 316 Stainless Steel, Glass lens, IP66 & IP68 - FM/CSA Explosion Proof Certified Class I, Div I, Groups B, C And D Class II, III, Div 1, Groups E, F And G ATEX Explosion Proof Certified ATEX 2 GD, Exd I & IIC; IECEx, Exd I & IIC - Dimensions- L: 8.9" (226mm) W: 5.8" (147mm) H: 5.8" (147mm) - Weight Total: 5.5 Lbs (2.5 Kg) - Pressure: 5000 PSIA (345 Bar) - 3/8" dia. probe has only 0.11 square inch cross sectional area, thus even at high pipeline pressures the probe can be inserted with minimal force - 1/2" NPT Connection to valve, adapters allow interfacing to larger valves - All 316 Stainless Steel and PTFE wetted parts, small surface area for fast response time. Temperature Range - ExMa Moisture Meter: -20°C to +60°C - Electronics: -40°C to +85° - Moisture Sensor: -20°C to +60°C - Pressure Sensor: -20°C to +85°C - LCD operating: -20°C to +70°C storage: -30°C to +80°C Miscellaneous Features - Through the glass user interface buttons, allow operation while enclosure is closed - NIST traceable calibrations - Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. (All units auto-scaled) - Virtual Analyzer PC software for training and evaluation, allows the user to experience the exact interface on their own PC with voice explanations Options & Accessories Standard Accessories for ExMa moisture meter: - Pluggable Electrical Screw Terminal Connectors - Ex Certified Side Port (3/4" NPT) Plug OPTIONS ORDERING INFORMATION / PART NUMBER PhyMetrix Explosion Proof Moisture Probe — ExMaProbe Stainless Steel Enclosure — suffix -S Pressure sensor option 0-1000 psia automatic pressure correction — suffix -P Mounting Legs — suffix -M Analog Output 4/20 mA with HART® option — suffix -A RS-485 with Modbus® option — suffix -D Explosion Proof ATEX option — suffix -I If Required Specify Inlet and/or Outlet Adapters

Dew Point Sensor PLMa

PhyMetrix Loop-powered Moisture Analyzer Model:PLMa Technical Specifications Moisture Sensor (dew point sensor) - Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) - Accuracy: ±2°C temperature corrected - Repeatability: 0.8°C - Response time: 95% of step change in 3 min. - Sample flow: 1 LPM Temperature Sensor - Range: -40°C to +70°C - Accuracy: ±2°C Ergonomics - Easy and quick installation, no tools required Electrical - 5VDC to 28VDC two wire loop operation 4mA to 20mA - Housing isolated from 4-20mA Loop - Measurement resolution of moisture sensor: 1pF resulting in less than 0.01 ̊C - 5 pin M12 industrial connector IP68 when mating connector fully engaged - Mating connectors with molded cables approved for Hazardous Location use available - Two conductor cable min. 24AWG (for total cable length 1mile min. 20AWG) To meet CE requirements cable must be shielded. - Built-in digital I/O for optionally controlling relays Mechanical - All 316 Stainless Steel and PTFE wetted parts for fast response time. - Enclosure all stainless steel construction IP67 protection when installed - Dimensions (overall) including connector- L: 3.25″ (82.6mm) Dia: 1.62″ (41.3mm) - Process threads 3/4″-16 and 14mm x 1.25mm Oring-Seal and 1/4″NPT, can install with either threads - Weight Total: 6 oz (0.17 Kg) - Pressure: 5000 PSIA (345 Bar) Temperature Range - PLMa Analyzer: -20°C to +60°C - Electronics: -40°C to +85°C - Moisture Sensor: -20°C to +60°C Miscellaneous Features - NIST traceable calibrations - Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. - Digital & Analog: Two Wire 4/20mA loop with HART® - Transmitter stores all HART setup Typical Applications Dew Point Probe for: Compressed Air, Natural Gas, Cryogenic Gasses, Welding Gasses, Insulating Gasses SF6, H2, N2 etc….. Options & Accessories STANDARD ACCESSORIES Included: - 10 feet (3 meter) cable with molded M12 connector IP68 Not Shown But Included: - User’s Manual - NIST Certificate - Shipping Container with desiccant OPTIONS ORDERING INFORMATION | PART NUMBER PhyMetrix Loop-powered Moisture Analyzer Model:PLMa Included Accessories: 10 feet (3 meter) cable with molded M12 connector | PLMa RS-485 with Modbus® option | suffix – D

In-Situ Probe PLMa

Moisture Sensor (dew point sensor) Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) Accuracy: ±2°C temperature corrected Repeatability: 0.8°C Response time: 95% of step change in 3 min. Sample flow: 1 LPM Temperature Sensor Range: -40°C to +70°C Accuracy: ±2°C Ergonomics Easy and quick installation, no special tools required Electrical 5VDC to 28VDC two wire loop operation 4mA to 20mA with HART Housing isolated from 4-20mA Loop Measurement resolution of moisture sensor: 1pF resulting in less than 0.01 ̊C Two conductor cable min. 24AWG (for total cable length 1mile min. 20AWG) To meet CE requirements cable must be shielded. Built-in digital I/O for optionally controlling relays Mechanical All 316 Stainless Steel and PTFE wetted parts for fast response time. Enclosure all stainless steel construction IP67 protection Dimensions: 3.25″ (82.6mm) diameter Explosion Proof enclosure 2.5″ high Process threads 1/2″ NPT Weight Total: 6 oz (0.17 Kg) Pressure: 5000 PSIA (345 Bar) Temperature Range PLMa Analyzer: -20°C to +60°C Electronics: -40°C to +85°C Moisture Sensor: -20°C to +60°C Miscellaneous Features NIST traceable calibrations Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. Digital & Analog: Two Wire 4/20mA loop with HART® Transmitter stores all HART setup Typical Applications Dew Point Probe for: Compressed Air, Natural Gas, Cryogenic Gasses, Welding Gasses, Insulating Gasses SF6, H2, N2 etc….. STANDARD ACCESSORIES Not Shown But Included: - User’s Manual - NIST Certificate - Shipping Container with desiccant OPTIONS PhyMetrix Loop-powered In-Situ Moisture Probe | PLMa-PrbEx RS-485 Modbus option | suffix -D

Phymetrix USB – HART Interface modem Model: UHi

Phymetrix USB – HART Interface modem Model: UHi Plugs into a PC or laptop standard USB port and provides an interface to any HART communication program including PhyAI.exe. Allowing the user to read the PLMa analyzer measurement log it and or reprogram the PLMa HART setup such as range, units, etc.