Use: On-Line for Hazardous or Harsh Locations Special Features • Direct on the pipe mounting with swiveling quick connect. • Integral demister with drain valve, provides 360° view of contaminants. • Built-in Flow meter • Built-in Metering valve • Most Cost Effective • Through glass touch buttons • Flow Control Orifice at Inlet/Outlet • Built-in serviceable/cleanable 100 micron inlet Filter Other measurements: Temperature Power: 4/20mA Loop Powered Serial I/O: HART® Optnl RS485 Modbus Analog Out: 4/20mA Loop Pwrd. Alarm Contacts: Built-in digital I/O (TTL) Mounting: Direct on the pipe or on the panel mounting Process threads: ¾"-16 threads to sample cell Operating Pressure: Inlet 300 psi (20 Bar) Outlet 50 psi (3.4 Bar) Weatherproof: IP66 & IP68 Enclosure material: Stainless Steel, Glass lens Dimensions: W: 5.8" (147mm) H: 5.8" (147mm) L: 8.9" (226mm) Weight: 5.5 Lbs (2.5 Kg) Hazardous Location use: FM/CSA Explosion Proof Certified Class I, Div I, Groups B, C & D Class II, III, Div 1, Groups E,F&G ATEX Explosion Proof Certified ATEX 2 GD, Exd I & IIC; IECEx, Exd I & IIC

Phymetrix Explosion-Proof Moisture Probe Model: ExMa-Probe In-situ measurement without exhausting any of the sample gas Can be inserted into pressurized pipeline through 1/2" or larger ball valve Customized insertion lengths field adjustable Unique State of the Art Features; Menu-driven, intuitive, easy-to-use Natural Gas Dew Point Meter - -110°C to +20°C dewpoint Sensor - Fast, Accurate and Repeatable Moisture Meter - Built-in temperature compensation - optional built-in pressure sensor with compensation - optional 4/20 mA sink or source output - optional RS-485 Modbus interface - 3" viewport, NEMA 4X/IP67 & Explosion-proof - State-of-the-art electronics & software - Advanced User-friendly Interface - Continuous Status and Diagnostics display - On-screen histogram and trend graph - Programmable data logging, clock calendar - Virtual Analyzer PC s/w for training & evaluation - 316 Stainless Steel & PTFE wetted parts - NIST calibrations - Cost Effective Complete In-Situ System - Thru-the-Glass Touch User Buttons - Approved Explosion-Proof Installations USA, Canada, ATEX - Installation Indoor/Outdoor On-The-Pipe or Panel Technical Specifications natural gas dew point meter Sensor - Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) - Accuracy: ±2°C temperature corrected - Repeatability: 0.8°C - Response time: 95% of step change in 3 min. - Sample flow:1 LPM Temperature Sensor - Range: -40°C to +70°C; Accuracy: ±2°C Pressure Sensor - 2 to 1000 PSIA ±1%, 316L stainless steel wetted parts (higher pressure ranges available) Electrical - 3 automatic detection – self configuring power modes: 1) 90-260VAC 47-440Hz 2) 12-24VDC 10VA 3) Optional 4/20mA Loop Powered - Power modes 1 or 2 have the following I/O options: a) RS-485 isolated Modbus® interface b) Analog Output 4/20mA sink or source isolated with HART® c) up to 3 Alarm Relays – 3A, 250VAC contacts Mechanical - Enclosure - Aluminum or optional 316 Stainless Steel, Glass lens, IP66 & IP68 - FM/CSA Explosion Proof Certified Class I, Div I, Groups B, C And D Class II, III, Div 1, Groups E, F And G ATEX Explosion Proof Certified ATEX 2 GD, Exd I & IIC; IECEx, Exd I & IIC - Dimensions- L: 8.9" (226mm) W: 5.8" (147mm) H: 5.8" (147mm) - Weight Total: 5.5 Lbs (2.5 Kg) - Pressure: 5000 PSIA (345 Bar) - 3/8" dia. probe has only 0.11 square inch cross sectional area, thus even at high pipeline pressures the probe can be inserted with minimal force - 1/2" NPT Connection to valve, adapters allow interfacing to larger valves - All 316 Stainless Steel and PTFE wetted parts, small surface area for fast response time. Temperature Range - ExMa Moisture Meter: -20°C to +60°C - Electronics: -40°C to +85° - Moisture Sensor: -20°C to +60°C - Pressure Sensor: -20°C to +85°C - LCD operating: -20°C to +70°C storage: -30°C to +80°C Miscellaneous Features - Through the glass user interface buttons, allow operation while enclosure is closed - NIST traceable calibrations - Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. (All units auto-scaled) - Virtual Analyzer PC software for training and evaluation, allows the user to experience the exact interface on their own PC with voice explanations Options & Accessories Standard Accessories for ExMa moisture meter: - Pluggable Electrical Screw Terminal Connectors - Ex Certified Side Port (3/4" NPT) Plug OPTIONS ORDERING INFORMATION / PART NUMBER PhyMetrix Explosion Proof Moisture Probe — ExMaProbe Stainless Steel Enclosure — suffix -S Pressure sensor option 0-1000 psia automatic pressure correction — suffix -P Mounting Legs — suffix -M Analog Output 4/20 mA with HART® option — suffix -A RS-485 with Modbus® option — suffix -D Explosion Proof ATEX option — suffix -I If Required Specify Inlet and/or Outlet Adapters
CATEGORY

PhyMetrix Loop-powered Moisture Analyzer Model:PLMa Technical Specifications Moisture Sensor (dew point sensor) - Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) - Accuracy: ±2°C temperature corrected - Repeatability: 0.8°C - Response time: 95% of step change in 3 min. - Sample flow: 1 LPM Temperature Sensor - Range: -40°C to +70°C - Accuracy: ±2°C Ergonomics - Easy and quick installation, no tools required Electrical - 5VDC to 28VDC two wire loop operation 4mA to 20mA - Housing isolated from 4-20mA Loop - Measurement resolution of moisture sensor: 1pF resulting in less than 0.01 ̊C - 5 pin M12 industrial connector IP68 when mating connector fully engaged - Mating connectors with molded cables approved for Hazardous Location use available - Two conductor cable min. 24AWG (for total cable length 1mile min. 20AWG) To meet CE requirements cable must be shielded. - Built-in digital I/O for optionally controlling relays Mechanical - All 316 Stainless Steel and PTFE wetted parts for fast response time. - Enclosure all stainless steel construction IP67 protection when installed - Dimensions (overall) including connector- L: 3.25″ (82.6mm) Dia: 1.62″ (41.3mm) - Process threads 3/4″-16 and 14mm x 1.25mm Oring-Seal and 1/4″NPT, can install with either threads - Weight Total: 6 oz (0.17 Kg) - Pressure: 5000 PSIA (345 Bar) Temperature Range - PLMa Analyzer: -20°C to +60°C - Electronics: -40°C to +85°C - Moisture Sensor: -20°C to +60°C Miscellaneous Features - NIST traceable calibrations - Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. - Digital & Analog: Two Wire 4/20mA loop with HART® - Transmitter stores all HART setup Typical Applications Dew Point Probe for: Compressed Air, Natural Gas, Cryogenic Gasses, Welding Gasses, Insulating Gasses SF6, H2, N2 etc….. Options & Accessories STANDARD ACCESSORIES Included: - 10 feet (3 meter) cable with molded M12 connector IP68 Not Shown But Included: - User’s Manual - NIST Certificate - Shipping Container with desiccant OPTIONS ORDERING INFORMATION | PART NUMBER PhyMetrix Loop-powered Moisture Analyzer Model:PLMa Included Accessories: 10 feet (3 meter) cable with molded M12 connector | PLMa RS-485 with Modbus® option | suffix – D
CATEGORY

Moisture Sensor (dew point sensor) Range: -110°C to +20°C dewpoint ( -166°F to +68°F dewpoint ) Accuracy: ±2°C temperature corrected Repeatability: 0.8°C Response time: 95% of step change in 3 min. Sample flow: 1 LPM Temperature Sensor Range: -40°C to +70°C Accuracy: ±2°C Ergonomics Easy and quick installation, no special tools required Electrical 5VDC to 28VDC two wire loop operation 4mA to 20mA with HART Housing isolated from 4-20mA Loop Measurement resolution of moisture sensor: 1pF resulting in less than 0.01 ̊C Two conductor cable min. 24AWG (for total cable length 1mile min. 20AWG) To meet CE requirements cable must be shielded. Built-in digital I/O for optionally controlling relays Mechanical All 316 Stainless Steel and PTFE wetted parts for fast response time. Enclosure all stainless steel construction IP67 protection Dimensions: 3.25″ (82.6mm) diameter Explosion Proof enclosure 2.5″ high Process threads 1/2″ NPT Weight Total: 6 oz (0.17 Kg) Pressure: 5000 PSIA (345 Bar) Temperature Range PLMa Analyzer: -20°C to +60°C Electronics: -40°C to +85°C Moisture Sensor: -20°C to +60°C Miscellaneous Features NIST traceable calibrations Units of measure: °C & °F dewpoint, ppmV, ppmW, µB H 2 O vapor pressure, grams of H 2 O / m 3, Lbs H 2 O /10 6 standard cubic feet in Natural Gas. Digital & Analog: Two Wire 4/20mA loop with HART® Transmitter stores all HART setup Typical Applications Dew Point Probe for: Compressed Air, Natural Gas, Cryogenic Gasses, Welding Gasses, Insulating Gasses SF6, H2, N2 etc….. STANDARD ACCESSORIES Not Shown But Included: - User’s Manual - NIST Certificate - Shipping Container with desiccant OPTIONS PhyMetrix Loop-powered In-Situ Moisture Probe | PLMa-PrbEx RS-485 Modbus option | suffix -D
CATEGORY

Phymetrix USB – HART Interface modem Model: UHi Plugs into a PC or laptop standard USB port and provides an interface to any HART communication program including PhyAI.exe. Allowing the user to read the PLMa analyzer measurement log it and or reprogram the PLMa HART setup such as range, units, etc.
CATEGORY