NW
Consumables
ConsumablesInstrumentation

Z-1000 Sterilization Chamber

By XENON Corporation

High-Energy Pulsed Light System Specifications: Sterilization Chamber The Z-1000 Sterilization Chamber, with removable lamp housing and sample tray, is detached from the benchtop controller. Ozone is evacuated to ensure EPA ozone level compliance in the workplace. Forced air evacuation is in the range of 1-4 volumes per minute to ensure no heat buildup within the chamber during sterilization. The chamber does not evacuate airborne pathogens nor introduce airborne pathogens into the chamber while the system is in the ON cycle. Ozone-resistant microbe filters are used at both the inlet and outlets of the ventilation path to ensure containment of airborne pathogens. The chamber has an interlocking door connected with the safety interlock switches in the controller. The chamber and insert are made of stainless steel construction for ease of sterilization and disinfection. This construction also insures the chamber is able to withstand UV light and heat conditions experienced under normal operating conditions. A total of 11 positions are available in the sterilization chamber to quickly allow the operator to position the stainless steel sample tray below the flashlamp window. This feature facilitates studies with different pulse intensities on the sample. An optional light intensity monitor, Light Mark-XL™, is mounted on the side of the sterilization chamber. Description Sterilization Chamber Chamber w/removable tray & air filters; access door on front Sterilization Chamber Access door: Hinged; 45.72 x 15.24 cm (18 in x 6 in) Chamber material: Metal grade stainless steel Removable tray material: Metal grade stainless steel; movable to 11 positions within chamber Air filters: Ozone resistant microbe filters (2) Disinfecting methods, tray and chamber: Note 1 The sterilization chamber and tray can withstand sterilizing or disinfecting methods such as autoclaving (276°F steam at 30 psi for 30 minutes), glutaraldehyde (Cydex) and/or 7% chlorine bleach disinfectant wash Door interlock: High Voltage disabled at controller when chamber door open Chamber interlock cable: 0.6 meters (2-ft.) Chamber air cooling: Internal fan Mains AC power Sterilization chamber mains AC power: 1-phase 200-240 Vrms, 50/60 Hz, 3 amps, max (includes internal fan) Sterilization chamber mains power cord: 2.1 meters (7-ft.) Outline Dimensions (H x W x L) Sterilization chamber: 29.5 x 77.4 x 40.6 cm (11.6 in x 30.5 in x 16.0 in) Removable tray: 15.7 x 40.6 cm (6.2 in x 16 in) Operating Environment Temperature - operating: 0 - 40°C (32 -104°F) Temperature - storage: -40 to 85 oC Relative Humidity: 10 - 80% (non-condensing) Weight: 25.9 kg (57 lbs.)

More from XENON Corporation

The S-5000

Roll-to-Roll Photonic Sintering System Customizable, multi-lamp system for production sintering at thoughputs of up to 70 feet-per-minute.

The S-5100

Wide Width Photonic Sintering System Roll-to-roll, high-speed sintering of copper or silver inks on materials up to 50″ wide.

The S-2210

Wide Area Photonic Sintering Research System Compact system is designed to treat wide areas with high uniformity.

The RC-900

High Power Modular Pulsed Light System Modular system offering single lamp or dual lamp configurations for low heat, fast throughput curing.