NW
Metrology
MetrologyInstrumentation

EpiCurve® TT with Advanced Resolution (AR) option

By LayTec GmbH

Accurate in-situ monitoring of the wafer curvature helps to minimize bowing-related wafer temperature inhomogeneities, to achieve better uniformity and, ultimately, higher yields. One of the challenges during buffer growth is the increasing asphericity of the wafer. For processes that potentially cause aspherical wafer curvature, we offer the EpiCurve® TT with the Advanced Resolution (AR) option: - AR provides information on wafer curvature along two perpendicular directions, radial asphericity and azimuthal asphericity - AR measures the quantity of aspheric component and gives access to information about the layer formation - AR detects relaxation at an early stage and reduces signal fluctuations in the main (spherical) bow measurement caused by aspherical effects

More from LayTec GmbH

EpiTT

Combine measurements of temperature and reflectance at three wavelengths in one tool. EpiTT combines measurements of temperature and reflectance at three wavelengths in one tool. For True Temperature (TT), we apply the method of emissivity corrected pyrometry, which delivers the precise surface temperatures of opaque materials at 950 nm (Si, GaAs, InP). For materials that are transparent at 950 nm (GaN, Sapphire, SiC), EpiTT measures the temperature on the top side of the carrier. Measuring reflectance at three wavelengths monitors all essential properties of the growing layers, such as growth rate, film thickness, stoichiometry changes and morphology. EpiTT offers industry standard metrology for all kinds of epitaxial growth systems and is compatible with different main rotation frequencies in the range from 5-1500 rpm. Fields of application - Temperature range: T=450°C to 1300°C for large viewport systems/T=500°C to 1400°C for narrow viewport systems/other temperature ranges on request, e.g. 1500°C for UV LED applications, 1700°C for SiC - Wafer temperature with precision better than ±1K in a range of 600°C to 1400°C - Wafer and area selective measurements - True wafer temperature for opaque semiconductors such as InP, GaAs and Si - Pocket temperature for GaN, Sapphire and SiC Product features Emissivity corrected pyrometry: - Temperature range from 450°C to 1300°C for large viewport systems/500°C to 1400°C for narrow viewport systems / other temperature ranges on request, e.g. 1500°C for UV LED applications, 1700°C for SiC - Accuracy better than 1 K - Wafer and area selective measurements - True wafer temperature for opaque semiconductors such as InP, Graphite (SbS) - Pocket temperature for GaN, Sapphire and SiC Reflectance at three wavelengths: - 950 nm, 633 nm and 405 nm - Growth rate, layer thickness, roughness and other layer qualities - Full performance up to 1500 rpm main susceptor rotation - Further wavelength (e.g. 280nm, 365nm, 1550nm) for special applications are available on request

X Link® off-line

X Link® enables fast, automated, non-destructive and accurate evaluation of the level of EVA or polyolefin cross-linking in PV module encapsulation processes. In solar modules, the ethylene vinyl acetate (EVA) or polyolefin encapsulation protects the sensitive solar cells from the environment. In consequence the degree of intermolecular cross-linking of EVA or polyolefin is decisive for the long-term stability and performance of a module. Cross-linking is achieved by thermally curing the polymers during the lamination process. The X Link® system enables fast, automated, non-destructive and accurate evaluation of the level of EVA or polyolefin cross-linking immediately after lamination. It can be integrated into any solar module production site, offering a flexible platform for encapsulation quality control ranging from single point sampling to full module mapping. The stand-alone version is designed for lab applications, manual product sampling, areal mappings, R&D labs and pilot lines, ready to test full-size production-type modules with or without frames. High-resolution spatial mappings of the cross-linking degree and statistical evaluation can be performed. Furthermore, the manual off-line version allows multiple-point measurements on laminates and out-of-production modules, and modules from the field. This setup is a highly useful quality control tool for incoming goods inspection for EPCs, certifiers and consultants. Fields of application - Module encapsulation quality control in glass/backsheet solar module production Product features - Non-destructive test procedure - Testing time of only seconds per measurement points - Flexible module mapping capability - Data output in “% gel content”

EpiTT features in other tools

Both emissivity-corrected temperature monitoring and reflectance measurement at three wavelengths are included in all products in our EpiCurve® TT family of products. For reactors with multiple wafer ring configurations, the models with two or three EpiTT heads (EpiCurve®Twin TT and EpiCurve®Triple TT) allow for temperature and reflectance measurements at two or three independent positions respectively.

EpiTT for various MOCVD reactor types

All products in the EpiTT family (EpiTT, EpiTwin TT, EpiTriple TT) are available for various MOCVD growth systems such as: - Systems with satellite rotation - Showerhead-like systems - Systems with main susceptor rotation speed up to 1500 rpm - R&D type and customized MOCVD growth systems