By PAMAS
Purity Controls: Essential for the Highest Quality Standards Pharmaceutical production is a critical industry. Where purity controls are of essential importance, particle counters play a vital role. Whether in the production of infusion solutions, protein solutions or eye drops, or in ensuring the component purity of medical devices - a reliable particle counter is indispensable. When installing particle counters in the pharmaceutical industry, a lot of criteria need to be adhered to: - Compliance with pharmacopoeia regulations: Regulations such as USP <788>, USP <787>, USP <789>, Ph. Eur. 2.9.19 demand precise monitoring and documentation of particle number and size in various substances. - Ensuring medication purity: A central requirement in your industry is ensuring the purity of all medications, to guarantee their effectiveness and safety for patients. - Avoidance of infections and inflammations through µm particles: Even the smallest particles can pose serious health risks, so it is crucial to monitor and minimise their presence. - Avoidance of time-consuming microscopic particle measurement: Particularly with volatile and viscous samples, particle counters provide significant time savings over traditional microscopic measurement methods. Are the devices validated according to USP <1788>? PAMAS devices are validated according to the strict requirements of USP <1788>. This ensures that they meet the high standards of the pharmaceutical industry and provide traceable, accurate, reliable measurements. Is the particle counter software compliant with 21 CFR Part 11? Yes, the software of our particle counters is compliant with the requirements of 21 CFR Part 11 with regard to data integrity. This ensures the reliability and traceability of the recorded measurement data. What is the smallest measurement volume that the particle counter can process? PAMAS particle counters are designed for the measurement of very small sample volumes. For specific information on individual models and their capabilities, please contact our sales team. Is the operating software of PAMAS devices intuitive? Yes, we place great emphasis on user-friendly and intuitive operating software. This way, you can use the particle counters quickly and efficiently, allowing you to focus on your core work. How durable and low-maintenance are PAMAS devices? PAMAS particle counters are known for their durability and low maintenance requirements. Thanks to their robust construction and high-quality materials, our devices offer a long service life, thus minimising the total operating costs. Our Particle Counters Provide Solutions Our offerings go beyond just providing particle counters. Our devices are designed to meet the diverse and demanding requirements of the industry: - Global after-sales support: After the purchase of your devices, we continue to be at your disposal. Our support team operates worldwide and can assist you with technical questions or problems. - Solutions for smallest sample volumes: In accordance with the requirements of USP <787>, we offer devices that provide reliable measurement results even with very small sample volumes. This enables us to provide precise solutions for a variety of requirements. - Viscous & volatile liquids: Our devices are designed to work with a wide range of samples, including viscous and volatile liquids. This capability allows flexible use in various application areas. - Variable calibration ranges: Our particle counters offer variable calibration ranges from a maximum of 1-400 µm. This means that the sensitivity of the device matches your specific needs. - Sensors for high particle concentrations: With a maximum of 120,000 particles per millilitre, our devices are also suitable for samples with high particle concentrations.

Particle counter for the remote on-site analysis of fluid samples – pressureless sampling and up to 420 bar system pressure testing The PAMAS S40 is a portable particle counting system for oil-based liquids like hydraulic and lubricating oil. A wear resistant ceramic piston pump guarantees a constant flow. With a simple-to-use touch screen user interface, operation is easy and intuitive. The system is equipped with an integrated battery for up to three hours operation and a data storage of up to 4000 measurements. The system can be used for batch sampling and online measurements. Additional accessories are available. Applications - Hydraulic oils - Turbine and insulation oils - Gear oils - Phosphate ester based hydraulic fluids - Fuels Product features - Robust & convenient design - Lightweight only 8 kg - Customizable measurement analysis settings - Intuitive operation via touch screen - Automatic sample flow and volume control by wear resistant ceramic piston pump - Measurement from pressureless up to 420 bar system pressure - Pressureless measurement of fluids with viscosities of up to 1.000 cSt at 22°C (equal to ISO VG320) without the need for accessories - Use of any sample vessel (any customer specific or widely available containers) - Internal data storage of more than 4,000 measurements - Measurement printout via integrated thermoprinter - Same measurement accuracy as a laboratory unit - Multilingual menu navigation - Battery running time of more than 4 hours Standards and methods ISO 11171 ISO 4402 NAS 1638 SAE AS4059 ASTM D6786 CHARN ISO 11500 ISO 4406 GJB 420A SAE 749D ASTM D7647 ISO/DIS 11218.2 IEC 60970 GJB 420B GOST 17216 NAVAIR 01-1A-17 in connection with PAMAS PMA software Volumetric Sensor PAMAS HCB-LD-50/50 Available size ranges: 4–70 µm(c) (ISO 11171) 2–100 µm (ISO 4402) Max. particle concentration: 24.000 P/ml at 25 ml/min Other sensors for larger particle sizes or higher concentrations are available on request. Software PAMAS Download: used to transfer stored measurements to a PC PAMAS CMDM: Condition Monitoring Data Management PAMAS PMA: Particle Measuring and Analysing Software Versions - PAMAS S40 Standard for the measurement at up to 420 bar system pressure - PAMAS S40 Lube Oil for the measurement of highly viscous oil of up to 1,000 cSt - PAMAS S40 Skydrol for the measurement of phosphate ester based hydraulic fluids - PAMAS S40 AVTUR for the measurement of turbine fuel according to EI-IP 577 and DEFSTAN 91-091 as well as diesel according to IP PM FA PAMAS S40 GO All versions are optionally available in the robust PAMAS GO housing.
CATEGORY

Particle Measuring and Analysis Software The software programme PAMAS PMA is used to control the particle counters PAMAS SBSS, PAMAS SVSS and the instruments of the PAMAS S40 series. The particle numbers and sizes are classified within the sensor's size range according to national and international standards. The measuring report includes all sample parameters and the numerical and graphical presentation of the measuring results. The report is compliant with the cleanliness standards ISO 4406, SAE AS 4059, NAS 1638, GOST 17216, GJB 420 and NAVAIR 01-1A-17. The results are automatically stored and may be exported to Microsoft Excel for further evaluation.
CATEGORY

The PAMAS Download-Software is compatible with the portable particle counters PAMAS S40 and PAMAS S4031. With the aid of the software, measuring results can be transferred from the particle counter to a PC. The data are transferred at first into a text file, which can then be converted into the required format (e.g. Excel or PDF).
CATEGORY

Sensor type: PAMAS HX. Size range (potential interval of detection) in µm and µm(c): 4-70 µm(c) [only for oil]. Flow rate range in ml/min: 5 - 50 ml/min. Maximum concentration of particles per millilitre (P/ml) including a coincidence rate of 7.8 %: 24.000 P/ml. The sensor PAMAS HX is designed for the online particle counter PAMAS S50.