The Next Generation of Thermal Stability Testing for Biologic Drugs The TA Instruments RS-DSC (Rapid Screening-Differential Scanning Calorimeter) is a powerful and versatile instrument that revolutionizes the thermal stability testing of biologic drugs with its high efficiency and streamlined analysis. The TA Instruments RS-DSC Can Help - Accelerate thermal stability testing: The TA Instruments RS-DSC provides detailed insights into drug product thermal stability significantly quicker by analyzing up to 24 samples simultaneously. The TA Instruments RS-DSC's technology also simplifies characterization of highly concentrated drug products. - Improve efficiency: The TA Instruments RS-DSC ensures materials are used efficiently by utilizing disposable MFCs (Micro Fluidic Chips) to contain the sample. MFCs require <15 ul sample volume, and the design facilitates a cleaner, more streamlined operation by reducing the need for tedious sample dilution, repetitive instrument cleaning, and contamination risks. - Make more informed decisions: NanoAnalyze™ Software effortlessly handles the increased data volume produced by the TA Instruments RS-DSC, providing in-depth, precise insights about a molecule's thermal stability and thermodynamic properties. Groundbreaking Capabilities - Enhanced Throughput: The TA Instruments RS-DSC enables the analysis of 24 samples simultaneously which significantly speeds up research and accelerates biologic drug market entry. - Resource Efficiency: The TA Instruments RS-DSC's minimal sample volume requirements help ensure maximum material use and minimize cost. - High Concentration Proficiency: The TA Instruments RS-DSC excels in testing an extensive range of sample concentrations and has a unique capacity for analyzing very high concentration drug products efficiently and effectively. - Simplified Workflow: The TA Instruments RS-DSC streamlines operations by removing the need for sample dilution when working with high-concentration samples, and the disposable microfluidic chips reduce or eliminate the need for cleaning and reduce the risk of contamination. - Comprehensive Data Analysis: NanoAnalyze Software manages data and provides detailed insights to optimize development. Features & Benefits - Parallel Analysis: Unique high throughput analysis enables up to 24 simultaneous measurements to accelerate research. - Single-Use Microfluidic Technology: MFCs streamline operation by simplifying the characterization of high concentration drug products, as well as reducing cleaning time and contamination risks. - State-of-the-Art Data Analysis Software: The robust and user-friendly NanoAnalyze Software automatically and consistently analyzes data for in-depth and rapid evaluation. RS-DSC Cell Geometry Disposable microfluidic Cell Material Glass Sample Format MFC (Micro Fluidic Chips) Working cell volume 11 µL Sample Capacity 24 MFCs Typical Sample Concentration 20 mg/mL – 330+ mg/mL IgG (protein dependent)1 Sample throughput> 96 samples/day Temperature Range 20-100 °C Temperature Scan Rate 1 or 2 °C/min Temperature accuracy± 0.2 °C (across all calorimeters); ± 0.1 °C reproducibility 2 1 Using lysozyme in 0.1 M glycine buffer at pH 2.5 at 1 °C/min 2 Using DPPC in water at pH 7 at 1 °C/min Accelerate research, improve efficiency, and make more informed decisions with the TA Instruments RS-DSC, a revolutionary new high-throughput thermal stability testing instrument specifically designed for biologic drug development. Technology Groundbreaking Capabilities The TA Instruments RS-DSC redefines the landscape by simultaneously analyzing 24 samples, significantly scaling up from traditional single-sample approaches. It operates with less than 15µL per sample, a substantial reduction compared to conventional capillary DSCs, and generally provides clearer picture of the thermodynamics of unfolding than differential scanning fluorescence (DSF). Microfluidic Technology: The Future of Precision and Convenience Equipped with cutting-edge MFCs (Micro Fluidic Chips), the TA Instruments RS-DSC is designed to contain the sample effortlessly. This technological integration eliminates the need for repetitive cleaning of the instrument measurement cell between runs, saving time, reducing the risk of contamination, and enabling more precise and reliable readings. The MFCs are disposable and enhance operational ease, enabling quick transitions and safeguarding the instrument from hazardous substances. The novel MFC design exemplifies cutting-edge, low-volume, single-use technology, facilitating ease of sample loading and preparation with standard lab equipment. A sample can be prepared, sealed, and ready for analysis in less than one minute, requiring only minimal volumes for precise evaluation. Applications The TA Instruments RS-DSC is ideal for a wide range of applications in biologic drug development, including: Formulation Buffer Screening Thermal stability is a leading indicator of overall clinical success of a biologic drug product, and DSC (Differential Scanning Calorimetry) is a primary tool that is used to characterize the effect of the solution environment on protein stability. Effects on protein stability can be reflected in small shifts in T max or in changes of up to tens of degrees resulting from altering variables such as pH, buffer, ionic strength, excipients, and detergents on protein stability. To demonstrate how the data from formulation screening can aid in selection of buffer components, the antibody trastuzumab was tested in four common buffer conditions: 1) A common working buffer (PBS), 2) A lysine-conjugation enabling buffer for the synthesis of labeled antibody for cellular trafficking studies or drug conjugation (borate), 3) A trastuzumab-based antibody drug conjugate (succinate), and 4) The native formulation buffer for trastuzumab (histidine). The first unfolding event, corresponding to unfolding of the C H 2 domain is not significantly impacted by the histidine, borate, or PBS buffers. However, the succinate buffer destabilizes the C H 2 domain resulting in lowering the onset of unfolding and T max,1 by about 3°C. With respect to the main transition reflecting the Fab and C H 3 unfolding events, the histidine and succinate buffers are the most stabilizing, with a T max,2 of 82.66°C. The main transition is least stable in the borate buffer with a T max,2 of 80.69°C. Unsurprisingly, the most stabilizing buffer formulation for trastuzumab in this sample set is the histidine buffer used for final formulation of the approved drug product. Protein Mutational Analysis – Characterize engineered protein modifications to understand the structural impact on molecular stability Protein mutations are a common strategy for optimizing protein structure and function, and even single amino acid modifications can have a measurable effect on overall protein stability. Using DSC (Differential Scanning Calorimetry) to aid in characterization of engineered protein modifications is essential for understanding the structural impact of the mutation on the protein as a whole and can help guide decision making in the biologic drug development pipeline. To demonstrate the types of effects sequence modification can have on stability, a small panel engineered proteins were screened for changes in thermal stability resulting from single amino acid mutations in the protein sequence. In the parent, unfolding occurs within one major thermal transition at a T max of 75.92°C. A single amino acid mutation was made which has no major effect on short-term thermal stability (Mutation 1); however, alternative single amino acid mutations are shown to have significant impacts on the protein's stability (Mutation 2 and Mutation 3). As illustrated in the significant destabilization in Mutation 3, modification does not always have the same effect, rather it depends on both the site of the modification and on physicochemical properties of the new amino acid. Optimizing the desired functional benefits of sequence modification with the structural stability of the protein as a whole aids in the comprehension of the structure-function relationship and can facilitate development of advanced therapeutics. Concentration Dependence – Investigate stability changes in highly concentrated drug products The TA Instruments RS-DSC is uniquely designed to handle high concentration biologic drug samples, with a specialized focus on antibody drugs and antibody drug conjugates. With the growing success of antibody therapeutics, the pharmaceutical industry has increased interest in high concentration dosage forms that enable subcutaneous and ocular drug delivery. As such, formulations with concentrations of 50 – 150 mg/mL antibody are common and can be as high as 200+ mg/mL. Formulating proteins at high concentrations can increase susceptibility to physical instability. Conversely, some cases studies have shown enhancement in thermal stability at increased concentrations Thus, understanding of thermal unfolding and response to the solution environment at the formulation concentration of interest is a critical metric for mitigating drug product liability. To demonstrate the ability to test high concentration protein samples and illustrate the importance of testing at the desired formulation concentration, we evaluated chicken egg white lysozyme from 30 – 330 mg/mL in glycine buffer. With a simple single transition thermogram at low concentrations (~1 mg/mL), lysozyme is commonly used as a reference test sample for DSC. Through evaluation of protein concentrations up to 100-fold higher, we observed a concentration dependence on lysozyme stability.
Empower Every User to Perform Rheological Measurements The Core Rheometer is the first system to combine wide-ranging measurements of viscosity and viscoelasticity with streamlined, walk-up usability. The new RheoGuide user interface enables complete operation directly from the touch screen, with direction, illustration and validation at every step. The new TA Instruments | Waters Discovery™ Core Rheometer empowers every user to perform rheological measurements, guiding formulation development, optimizing performance and ensuring product quality. Whether you are new to rheology, upgrading your quality control testing, or expanding capabilities to meet growing demands, the Core Rheometer empowers your lab to discover insights into your materials’ behavior needed to advance your goals. Discover Insights Beyond Viscosity: While viscometers report only a single viscosity value within a limited range, the Core Rheometer captures the complete viscosity profile, representing material behavior across all relevant conditions. Complex fluids like suspensions, emulsions, gels, pastes and slurries are non-Newtonian. Their viscosity changes with the applied shear rate and time; it is not a single value. Characterizing the full range of viscosity is critical to understand flow behavior under real-world conditions. Rheometer Advantages: - Precision and accuracy - Range of measurement - Controlled shear rate - Replicate process conditions - Small sample volume - Rapid temperature control Test Modes: - Flow - Oscillation - Transient Designed to Streamline Every Step: 1. Automatic gap control provides faster workflow and precise gap positioning. The axial motor automatically raises and lowers the head throughout the method and controls the test gap position with 0.1 um resolution for accurate and reproducible results. 2. Touchscreen capabilities go beyond basic controls, providing a new user experience ideal for high-throughput labs. Perform routine measurements directly at the instrument without need for PC interaction. 3. Integrated lighting enhances visibility for easier, more reproducible sample preparation leading to increased data accuracy and precision. The sample is automatically spotlighted during user interaction, guiding the operator and signaling test status. 4. Smart Swap™ 2 reader automatically identifies attached geometry, recalls dimensions and stored calibrations, and validates geometry aligns with the selected RheoGuide™ method. Smart Swap eliminates common sources of error and enables more efficient operation. 5. Compact design incorporates electronics, Peltier and air-cooling heat exchanger in one unit. Compared to modular systems with liquid circulators, the Core Rheometer requires up to 75% less bench space. Core Temperature Technology: Temperature control is key for accurate rheology data to ensure data reproducibility and evaluate materials’ behavior under real-world conditions. The Core Rheometer’s integrated Peltier system provides precise, rapid temperature control. Equilibration time is reduced by up to 60% compared to typical viscometer configurations, minimizing down time between different measurements. Built-in air cooling eliminates the need for a liquid circulator, reducing cost, simplifying operation, and saving valuable bench space. Configuration: Peltier Plate -10 °C to 200 °C Peltier Concentric Cylinder 0 °C to 150 °C Measurement Specifications: Minimum Torque (Oscillation) 0.1 µN.m Minimum Torque (Steady Shear) 0.3 µN.m Maximum Torque 125 mN.m Torque Resolution 10 nN.m Displacement Resolution 100 nrad Maximum Rotational Velocity 300 rad/s Minimum Angular Frequency 10-4 rad/s Maximum Angular Frequency 628 rad/s Motor Inertia < 25 μN.m.s2 Gap Positioning Speed 10 mm/s Dimensions (width x height x depth) 30 cm x 77 cm x 42 cm / 11.8 in x 30.3 in x 16.3 in Weight 34.5 kg (76 lb)
CATEGORY
The advanced Waters TA Instruments ARES-G3 Rheometer pushes rheology further, delivering sharper data across more conditions. Building upon 55 years of rheology innovation, the ARES-G3 Rheometer’s cutting-edge technology and precision hardware capture real fluid behavior with fewer adjustments and more accurate outcomes. Precision Powered by Innovation: Equipped with advanced motor technology and a force rebalanced transducer (FRT), the ARES-G3 Rheometer delivers enhanced accuracy and dependable performance in critical rheological measurements. - Measurement accuracy – achieve measurements closer to true fluid dynamics, with no geometry or inertia calibrations required, powered by separate motor transducer (SMT) technology and accurate temperature control for confident high-temperature testing - Data and insights – capture higher quality data under a wider range of rheological conditions with dual data acquisition, faster rates, and improved functionality, plus reduced QC testing time by up to 80% with the integrated optimally windowed chirps (Fast Frequency Chirps) workflow - Usability and efficiency – benefit from modern, intuitive software with fewer calibrations, walk-up usability, and faster throughput for a seamless and efficient testing experience Engineered for Next-Generation Rheology: - Reliable testing environment: Dual gun heaters ensure faster, accurate oxygen exclusion for polymer and composite testing - Superior accuracy: Separate motor transducer (SMT) technology and force-rebalanced transducer (FRT) deliver cutting-edge data with minimal corrections - Enhanced data capture: High-speed acquisition and Fast Frequency Chirps cut test time by up to 80% - Intuitive controls: Updated touchscreen and keypad simplify experiment setup and operation - Trustworthy data: Access raw phase angles and waveforms for deeper insights - Software: TRIOS Express Software enables quick setup, fewer calibrations, and walk-up usability Separate Motor and Transducer (SMT) Technology: The ARES-G3 Rheometer’s SMT design sets a new benchmark in precision by decoupling the motor from the measurement, eliminating common calibration protocols and uncovering nuanced material behaviors that standard systems often miss. This independence is especially valuable for high-fidelity deformation testing like large amplitude oscillatory strain (LAOS), and for evaluating soft or complex materials such as emulsions and polymers under challenging conditions. At the core of SMT lies the force rebalanced transducer (FRT), which stays motionless and captures the sample’s true response with minimal disruption from motor dynamics. When paired with the powerful drive motor, it delivers cleaner data free from typical mechanical noise, giving researchers greater confidence in their rheological insights. Mechanical Properties / Material Characteristic Measured: - Elastic (Young’s) modulus – Stiffness - Yield strength – Maximum stress before permanently deforming - Ultimate strength – Maximum stress supported by material - Elongation at break – Length change at breaking point - Fatigue life – Durability under repeated loading - Creep compliance – Deformation over time at constant load - Stress relaxation – Decrease in stress over time - Fracture toughness – Amount of stress to fracture - Fatigue crack growth – Amount cracks grow under repeated loading One Rheometer, Many Applications: Thermosets: Thermoset testing demands fast, accurate insight into curing, gelation, and viscoelastic changes as materials react to heat. Advanced methods like Fast Frequency Chirps unlock a new dimension of curing analysis, while precise thermal control and SMT architecture ensure reliable data across wide temperature ranges. Complex Fluids: Complex fluids like emulsions, suspensions, and slurries exhibit dual-phase behavior and complex mechanical responses. Advanced rheological tools provide the control and clarity needed to uncover their fundamental interactions and link them to bulk properties. Polymer Melts: Polymers shift from viscous melts to rigid solids, requiring full rheological characterization, extensional viscosity, melt rheology, and DMA, to optimize processing and performance. Advanced tools with purpose-built hardware and Fast Frequency Chirps methods accelerate testing while minimizing corrections. Revolutionizing Rheology with Fast Frequency Chirps Technology: New optimally windowed chirps (Fast Frequency Chirps) technology as integrated in TRIOS Software transforms rheology frequency sweeps by dramatically boosting speed and data density, especially at low frequencies. Fast Frequency Chirps enables ramped time temperature superposition (TTS) master curves generation in under an hour, replacing multi-hour tests without compromising accuracy. Unlike traditional single-frequency methods, Fast Frequency Chirps’ rapid sweeps track fast-changing systems like curing or chemical reactions, making it ideal for polymers, thermosets, and composites. Fully integrated into TRIOS Software, Fast Frequency Chirps streamlines workflows with automated analysis, delivering faster, high-quality results with ease. Enhanced Measurement Capabilities: Powered by cutting-edge hardware and a streamlined SMT architecture, the ARES-G3 Rheometer stands out as a top choice for sophisticated testing applications. Its rapid-response motor enables precise execution of intricate or user-defined deformation patterns, offering flexibility beyond conventional testing protocols. Meanwhile, the force rebalanced transducer (FRT) system ensures data integrity with minimal need for correction, delivering results that closely reflect authentic material behavior and inspire total confidence in analysis. Real Rheology for Real-World Applications: Rheology matters most when it reflects real-world performance. The ARES-G3 Rheometer simulates a wide range of conditions, from temperature shifts to force and pressure, so materials can be designed and tested with confidence and precision. Ultimate Upgrade Flexibility: The ARES-G3 Rheometer features a modular design and high-performance core, offering a scalable platform that evolves with research and quality control needs. - Faster workflows can accelerate routine testing and data procession, helping improve lab efficiency - Expanded testing capabilities add support for solid material testing and advanced viscoelastic measurements - Enhanced data acquisition help capture more detailed, simultaneous data for deeper material insights - Advanced control features enable complex deformation profiles and waveform customization for cutting-edge research Specifications: Force/Torque Rebalance Transducer (Sample Stress) Minimum Transducer Torque in Oscillation 0.02 µN.m Minimum Transducer Torque in Steady Shear 0.1 µN.m Transducer Torque Resolution 1 nN.m Transducer Normal/Axial Force Range 0.001 to 20 N Drive Motor (Sample Deformation) Maximum Motor Torque 800 mN.m Strain Resolution 0.04 µrad Min. Angular Displacement in Oscillation 1 µrad Angular Velocity Range 1 x 10-6 rad/s to 300 rad/s Angular Frequency Range 1 x 10-7 rad/s to 628 rad/s Step Change in Velocity 5 ms Step Change in Strain 10 ms Temperature Systems Forced Convection Oven, FCO-150 °C to 600 °C Advanced Peltier System, APS-10 °C to 150 °C Dynamic Mechanical Analyzers 0.0005 N
CATEGORY
TA Instruments invites you to experience the finest in Thermomechanical Analyzers, the Discovery TMA 450. Discover the advanced engineering and attention to detail that provides enhancements in every aspect of performance and a new level of user experience. Featuring advanced testing capabilities and the widest range of fixtures, the Discovery TMA 450 is sure to meet and exceed your expectations. Features and Benefits: - Non-contact, friction-free motor delivers forces from 0.001 N to 2 N enabling measurements on the widest range of samples, from soft compressible elastomers to stiff composite materials. - Wide-range, high-resolution measurement transducer accommodates sample lengths up to 26 mm and a measuring range of ±2.5 mm with resolution as low as 15 nm for an accurate dimensional change measurement. - Advanced testing modes of Modulated TMA (MTMA ™), Dynamic TMA, Creep and Stress Relaxation extend capabilities and empower users with even more valuable information about the mechanical behavior of materials. - Convenient Mechanical Cooling Accessory (MCA 70) provides temperature control to -70°C without the cost or hassle of liquid nitrogen. - Powerful TRIOS software delivers exceptional user experience and ease-of-use in a combined package for instrument control, data analysis, and reporting, reducing training times and raising productivity to new levels. - New, innovative, "app-style" touch screen puts instrument functionality simply One-Touch-Away™, enhancing usability and making it easier than ever to get great data. - Every instrument comes with a commitment to quality backed by the industry's ONLY five-year furnace warranty for peace of mind. With the ever-increasing demands for higher performing materials to meet the needs of challenging applications, understanding how a material reacts to its environment is more important than ever. Meeting and exceeding industry standards for testing, the Discovery TMA 450 provides information about the material's coefficient of linear thermal expansion (CTE), shrinkage, softening, glass transition temperatures, and much more. The advanced options can be used to obtain viscoelastic properties such as the material's stiffness (modulus), damping properties (tan delta), creep, and stress relaxation. The TMA 450 is particularly useful for measuring these material properties locally, especially in manufactured components or assemblies where compatibility of materials is paramount. ASTM E831, E1545, D696, D3386 and ISO 11359: Parts1-3 Furnace: The TMA 450 features a highly-responsive low-mass furnace designed for the most precise control of temperature from -150°C to 1000°C and stable heating rates in the range of 0.1 to 100°C/min. The furnace ensures the superior baseline performance required for accurate dimension change measurements, as well as the dynamic temperature control required for Modulated TMA™ operation. The air-cool feature facilitates experiment turnaround times in as little as 10 minutes, significantly improving laboratory productivity. The integrated Inconel® 718 Dewar atop the furnace enables liquid nitrogen cooling to -150°C, or the instrument can be connected to the optional nitrogen-free Mechanical Cooling Accessory (MCA 70) for cooling to -70°C. Sample Stage: The sample stage and probes are made of quartz and are optimized for an operational range of -150°C to 1000°C. Quartz is an ideal material because of its rigidity, inertness to corrosion, and very low thermal expansivity. The easily accessible stage simplifies probe or fixture installation, sample mounting, and thermocouple placement. The quartz probes are designed to be used in expansion, penetration, flexural (3-point bend) and tension modes of deformation. An integrated dual-input gas module provides purge gas atmosphere (air, argon, helium, or nitrogen) to the sample area to a maximum flow rate of 200 mL/min. High Performance Displacement Transducer: At the heart of the TMA 450 is a displacement transducer, which directly measures sample dimension change with great precision and accuracy over a wide displacement and temperature range (-150 to 1000°C). The measurement system provides 15 nm resolution and ±2.5 mm dynamic range for samples up to 26 mm in length. Friction-Free Force Motor: A non-contact motor provides a friction-free controlled force to the sample over a range of 0.001 to 1 N. The force can be increased to 2 N by addition of weights. Standard Tests include: - Temperature Ramp - Force Ramp - Isostrain - Custom Edited Procedure Advanced Tests (Enhanced Mode–EM) include: - Stress Ramp - Strain Ramp - Creep - Stress Relaxation - Modulated TMA (MTMA ™) - Dynamic Temperature Ramp (Force Modulation) - Manual (a combination of advanced test types) Typical properties and behaviors measured by the TMA include: - Linear thermal expansion - Coefficient of thermal expansion (CTE) - Phase transition temperatures - Glass transition temperatures - Shrinkage or contraction - Softening points - Volumetric expansion - Delamination - Residual cure reactions - Stress - Decomposition temperature Advanced TMA tests provide: - Storage and loss moduli (E', E") - Damping properties (tan delta) - Relaxation behavior - Creep and recovery - Stress relaxation - Stress-strain curves - Shrink force - Deconvolution of simultaneous expansion and shrinkage The Discovery TMA 450 features TA's innovative touch screen, making operation easier than ever with enhanced One-Touch-Away™ functionality.
CATEGORY
TA Instruments' state-of-the-art software package uses cutting-edge technology for instrument control, data collection, and data analysis for thermal analysis and rheology. The intuitive user interface allows you to simply and effectively program experiments and move easily between processing experiments and viewing and analyzing data. Ease of Use: TRIOS software makes calibration and operation of the TMA 450 simple. Users can easily generate multiple calibration data sets under varying experimental conditions (e.g. different heating rates or gas selections) and seamlessly switch between them to match the experimental conditions used for sample testing. Real-time signals and the progress of running experiments is readily available, with the added capability of modifying a running method on the fly. TRIOS software offers a level of flexibility that is unmatched in the industry. TRIOS Features: - Control multiple instruments with a single PC and software package - Overlay and compare results across techniques including TMA, DMA, DSC, TGA, SDT, and rheometers - Unlimited licenses and free lifetime software upgrades - One-Click analysis for increased productivity - Automated custom report generation comprising: experimental details, data plots and tables, analysis results - Convenient data export to plain-text, PDF, CSV, XML, Excel®, Word®, PowerPoint®, and image formats - Optional TRIOS Guardian with electronic signatures for audit trail and data integrity Complete Data Record: The advanced data collection system automatically saves all relevant signals, active calibrations, and system settings. This comprehensive set of information is invaluable for method development, procedure deployment, and data validation. Quick & Easy Calibration: TRIOS software makes calibrating the sample fixtures/probes and the TMA 450 effortless. Clear instructions, available on both the touch screen and TRIOS software, guide the operator through simple calibration steps that end with a summary report. The report provides calibration status at a glance and is stored with each data file to ensure data integrity. Standard SA Analyses: - Alpha at X1 (CTE) - Alpha at X1 to X2 (CTE) - Alpha fit X1 to X2 (CTE) - Onset and endset analysis - Dimension change (absolute and %) - Step transition - Curve values at specific X or Y points - 1st and 2nd derivatives - Mathematical fitting: straight line, polynomial, or exponential - Stress and strain curves Advanced Analysis Capabilities on the TMA 450EM: - Storage and loss moduli, with tan delta peak analysis when using Dynamic TMA - Deconvolution of the Total Dimension Change signal with Modulated TMA™ (MTMA™) into Reversing and Non-Reversing dimension change signals for separating expansion from contraction, shrinkage, and stress relaxation
CATEGORY