
By XOS
Rapid sulfur measurement plus 12 other critical elements. Benefits and features 1. Advanced detection performance over traditional XRF technology 2. Precise sulfur measurements with an LOD as low as 5.7 ppm and rapid monitoring of critical elements 3. Easy to use - just plug in and measure 4. Petra MAX is powered by XOS’ EDXRF technology: an elemental analysis technique that offers significantly enhanced detection performance over traditional XRF. This technique applies state-of-the-art monochromating and focusing optics, enabling a dramatically higher signal-to-background ratio compared to traditional polychromatic X-ray Fluorescence Specifications Autosampler: Yes Calibration Curves: 30 calibration curves, linear (automatic calibration available) Catalysts: Yes Communication Capabilities: Printer, USB & Ethernet, LIMS integrated Elements & Concentrations: Sulfur: 5.7 ppm; Phosphorus: 17 ppm; Chlorine: 3 ppm; Potassium: 0.7 ppm; Calcium: 0.4 ppm; Vanadium: 0.1 ppm; Chromium: 0.09 ppm; Manganese: 0.07 ppm; Iron: 0.07 ppm; Cobalt: 0.07 ppm; Nickel: 0.04 ppm; Copper: 0.1 ppm; Zinc: 0.1 ppm Dimensions (Depth): 16.5 in / 41.9 cm Dimensions (Height): 6 in / 15.3 cm Dimensions (Width): 14.5 in / 36.8 cm Measurement Time: User selectable 30-900 s Method Name: ASTM D4294, ISO 8754, IP 336 Options: Vibration plate Range: Sulfur 5.7 ppm (mg/kg) - 10 wt% Sample Cup Type: Standard XRF sample cup Specific Technology: EDXRF What's Included: spare fan filter, 100 sample cups, 100 Etnom sample films, 25 Mylar sample basket windows, sulfur calibration set, 4x10mL multi-element calibration set, sample cup stand, and thumb drive (contains manuals, best practices guide, calibration guide, quick-start guide).

Effective online sulfur analysis in petroleum process streams. Benefits and features 1. Continuous monitoring with programmable response times 2. Direct and non-destructive - No consumables, no gasses, no high temperature processes 3. Outstanding linearity - One calibration for diesel and gasoline matrices over the full dynamic range 4. Extremely low maintenance Specifications Calibration Curves: 3- to 5-point linear calibration curve Catalysts: No Communication Capabilities: 4-20 mA; Modbus and Ethernet optional Consumable/ utility gas: Instrument air or nitrogen Elements & Concentrations: Sulfur/ 0.5 ppm (mg/kg) Dimensions (Depth): 18 in / 45.7 cm Dimensions (Height): 60 in / 152.4 cm Dimensions (Width): 38 in / 96.5 cm Measurement Time: User selectable (15-300 s typical) Method Name: ASTM D7039 Number of sample streams: One. Optional up to four. Options: C1D2 or ATEX compliant; Sample conditioning system; High range Range: 0.5 ppmw - 3000 ppmw. Extended Range (XR) available XRF Film Type: Kapton What's Included: Base system includes: - SINDIE 6010 On-Line MWD XRF analyzer based on ASTM method D 7039 - Rated for area classification CLASS I Div 2 Groups B, C, D T4A - Stainless steel nameplate - Dynamic range 0.6 - 3000 ppm wt. - Signal output: (2) user configurable 4-20 mA result outputs - Manual sample valve for lab verification - Sample Management System - Modular valves for the introduction of calibration fluids - Pressure and flow regulators/meters -Five (5) 300cc SS sample cylinders for calibration fluids - One (1) reference literature library includes: One (1) Installation Manual, One (1) User Manual, One (1) Maintenance Manual, One (1) CD copy containing all of the above -One (1) Dynamic Window Module
CATEGORY

Online Chlorine Analysis in Liquid Hydrocarbon Process Streams. Benefits and features 1. Optimize performance and immediately see impacts of crude changes (including organic chloride) 2. Direct measurement without sample conversion - Analysis in ppm (wt) 3. Can be used for multiple applications, including upstream desalting, power generation, effluent management, and others 4. Extremely low maintenance Specifications Calibration Curves: One Catalysts: No Communication Capabilities: 4-20 mA; Modbus and Ethernet optional Consumable/ utility gas: Instrument air or nitrogen Elements & Concentrations: Chlorine/ 0.2 ppm (mg/kg) in hydrocarbons, 0.6 ppm (mg/kg) in aqueous streams Dimensions (Depth): 18 in / 45.7 cm Dimensions (Height): 60 in / 152.4 cm Dimensions (Width): 38 in / 96.5 cm Measurement Time: User selectable (15-300 s typical) Method Name: ASTM D7536 Number of sample streams: One. Optional up to four. Options: C1D2 or ATEX compliant; Sample conditioning system Range: 0.2 ppmw - 3000 ppmw XRF Film Type: Kapton What's Included: Base system includes: - Clora Online MWDXRF analyzer - Rated for area classification CLASS I Div II Groups B, C, D T4A - Stainless steel nameplate - Signal output: Two (2) user configurable 4-20 mA result outputs; up to 4 alarm outputs (volt-free) - Manual sample valve for lab verification - Sample management system Modular valves for the introduction of calibration fluids Pressure and flow regulators - One (1) reference literature library includes: - One (1) Installation manual - One (1) User manual - One (1) Maintenance manual - One (1) CD copy containing all of the above - Includes one (1) high viscosity dynamic window module
CATEGORY

From hydrocarbons to plastics, Petra® SUPRA delivers total light element analysis with quick cycle times and no sample preparation. Benefits and features - Low maintenance: no gasses, heating elements, columns, or quartz tubing - Total light element analysis in a wide range of materials, including hydrocarbons, plastics, polymers, and other chemicals - Small footprint - For use in refinery labs, pipeline terminals, inspection laboratories, and manufacturing QC labs Specifications Autosampler: No Calibration Curves: 30 calibration curves Catalysts: Yes Communication Capabilities: Printer, USB & Ethernet, LIMS Integrated Elements & Concentrations: Sulfur / 0.13 ppm (mg/kg); Phosphorus / 0.25 ppm (mg/kg); Potassium / 0.06 ppm (mg/kg); Calcium / 0.03 ppm (mg/kg); Magnesium / 29 ppm (mg/kg); Sodium / 160 ppm (mg/kg); Silicon / 0.6 ppm (mg/kg); Aluminum/ 2 ppm (mg/kg) Dimensions (Depth): 16.5 in / 41.9 cm Dimensions (Height): 6 in / 15.3 cm Dimensions (Width): 14.5 in / 36.8 cm Measurement Time: User selectable 30-900 s Method Name: ASTM D4294, ISO 8754, ISO 13032, and IP 336 Options: Printer (US/CA only), calibration standards, consumables Range: Sulfur 0.13 ppm (mg/kg) - 10 wt% Sample Cup Type: 30 mm sample cup Specific Technology: EDXRF What's Included: 100 sample cups, 100 sample films, 100 pipettes, 1 sulfur calibration set, 1 refinement calibration set, sample cup stand, and thumb drive (contains manuals, best practices guide, calibration guide, quick-start guide). Applications: Petrochemical, Sustainable Aviation Fuel, Plastic Pyrolysis Our solutions are built to effortlessly meet strict ISO, ASTM, and industry regulatory standards.
CATEGORY

Online Sulfur and Metals Analysis in Streams. Benefits and features 1. Continuous, real-time analysis 2. Rapid response to upsets 3. Low maintenance: no consumable liquids, gasses, combustion, or sample conversion 4. Not sensitive to sample temperature changes Specifications Calibration Curves: Fundamental parameters, empirical custom call available Communication Capabilities: Multiple 4-20 mA analog outputs (one per element); Modbus and Ethernet optional Consumable/ utility gas: Instrument air or nitrogen Elements & Concentrations: Sulfur/ 20 ppm (mg/kg), Iron/ 0.1 ppm (mg/kg), Nickel/ 0.1 ppm (mg/kg), Vanadium/ 0.2 ppm (mg/kg) Dimensions (Depth): 18 in / 45.7 cm Dimensions (Height): 60 in / 152.4 cm Dimensions (Width): 38 in / 96.5 cm Measurement Time: 300 s Method Name: ASTM D4294, ASTM D8252 Number of sample streams: One (1) Options: Cabiet Heter/Cooler What's Included: Base system includes: - PetraMAX On-Line EDXRF analyzer based on ASTM Method D8252 and D4294 - Certified for area classification Class I Div 2 T4A Tamb = - 20C to +40C - Stainless steel nameplate - Manual sample valve for lab verification - Four (4) 300cc SS sample cylinders for calibration fluids - Sample Management System with automated valves, pressure regulators, flow meter and flow control - One (1) reference literature library includes: One (1) Installation manual One (1) User manual One (1) Maintenance manual One (1) CD copy containing all of the above - Includes one (1) high viscosity dynamic window module 403973-01 - Includes 4x500ml bottle set for Refinement Calibration - Includes 1x500ml bottle check sample (1000ppm S, 10ppm Ni, V and Fe each
CATEGORY