By Innovative Scientific Solutions Inc.
SDS # ISSI-012-EU Product Name: UniTemp Temperature Sensitive Paint (Liquid) Other means of identification Pure substance/mixture: Mixture Contains Toluene; Ethyl benzene; p-Xylene; o-Xylene Recommended use: Wind tunnel testing Supplier: Innovative Scientific Solutions, Inc., 7610 McEwen Road, Dayton, OH 45459 Contact Point: Innovative Scientific Solutions, Inc. Phone: (937) 630-3012, Fax: (937) 630-3015, Email Address: painting@innssi.com Emergency Telephone (24 hr): (937) 630-3012 x100 Emergency Telephone Number - §45 - (EC)1272/2008 Europe: 112 Classification according to Regulation (EC) No. 1272/2008 [CLP]: Flammable liquids Category 2 - (H225); Skin irritation Category 2 - (H315); Reproductive toxicity Category 2 - (H361d); Specific target organ toxicity (single exposure) Category 3 - (H336); Category 3 Target organ effects: Narcotic effects; Specific target organ toxicity (repeated exposure) Category 2 - (H373); Aspiration hazard Category 1 - (H304); Hazardous to the aquatic environment - chronic Category 3 - (H412) Contains Toluene; Ethyl benzene; p-Xylene; o-Xylene Signal word: Danger Hazard statements: H304 - May be fatal if swallowed and enters airways; H315 - Causes skin irritation; H336 - May cause drowsiness or dizziness; H361d - Suspected of damaging the unborn child; H373 - May cause damage to organs through prolonged or repeated exposure; H412 - Harmful to aquatic life with long lasting effects; H225 - Highly flammable liquid and vapour Precautionary Statements - EU (§28, 1272/2008): P201 - Obtain special instructions before use; P202 - Do not handle until all safety precautions have been read and understood; P210 - Keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking; P233 - Keep container tightly closed; P240 - Ground/bond container and receiving equipment; P241 - Use explosion-proof electrical, ventilating and lighting equipment; P242 - Use only non-sparking tools; P243 - Take precautionary measures against static discharge; P260 - Do not breathe dust, fume, gas, mist, vapors and spray; P264 - Wash face, hands and any exposed skin thoroughly after handling; P271 - Use only outdoors or in a well-ventilated area; P273 - Avoid release to the environment; P280 - Wear protective gloves, protective clothing, eye protection and face protection; P301 + P310 - IF SWALLOWED: Immediately call a POISON CENTER or doctor/physician; P331 - Do NOT induce vomiting; P303 + P361 + P353 - IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower; P362 - Take off contaminated clothing and wash before reuse; P332 + P313 - If skin irritation occurs: Get medical advice/attention; P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing; P312 - Call a POISON CENTER or doctor/physician if you feel unwell; P308 + P313 - IF exposed or concerned: Get medical advice/attention; P314 - Get medical advice/attention if you feel unwell; P370 + P378 - In case of fire: Use CO2, dry chemical, or foam to extinguish; P403 + P235 - Store in a well-ventilated place. Keep cool; P405 - Store locked up; P501 - Dispose of contents/ container to an approved waste disposal plant Additional information: This product requires tactile warnings if supplied to the general public. This product requires child resistant fastenings if supplied to the general public. This product does not contain any known or suspected endocrine disruptors. Contains Toluene; Ethyl benzene; p-Xylene; o-Xylene Contains Ti

The educational PSP/TSP system provides everything needed for new users to get started using PSP and TSP. This system provides high spatial resolution, excellent dynamic range, but lower data capture rates than our higher-end systems. For applications where time in the wind tunnel is not a critical issue, it represents an excellent cost/performance trade-off. This system provides full capability for undergraduate demonstrations, training, and laboratory exercises. It will support all but the most demanding graduate and faculty research programs requiring distributed pressure and temperature measurements in wind tunnel environments. The system employs proven ISSI LED technology for excitation of the luminous probes in the paints. The camera is based on a color CCD sensor, eliminating the need for a filter wheel when using bi-luminophore paints. The OMS-Lite software package is easy to use and fully supports the educational and research capabilities of the PSP/TSP system. Standard System Components: - Color CCD Camera: 12 bit, 1.9 Megapixel color CCD camera with Gigabit Ethernet connectivity - LM2X-DM-400 LED Array: High-power UV LED module with TTL control - PSG-3: Pulse/delay generator for instrument control and synchronization - Parbolic Reflector and Diffuser: Focuses output of LM2 series LEDs from 120- to 40-degrees giving 2-3 times increased focused output. - PSP/TSP Starter Kit: PSP starter kit including beginner paints in spray cans, Binary FIB and FIB Basecoat with HVLP paint gun and airbrush with compressor and fittings. - Optical Kit: This kit contains all lenses and filters needed to get started using PSP and TSP. Available with c-mount or Canon® EF mount lenses. - ProAcquire and OMS-Lite: Data acquisition and data reduction software. Test models used in the lab experiments are provided with the the educational PSP/TSP system. An aluminum delta wing and NACA 0012 airfoil model are included with the system along with the mounting hardware to install them for either 1/4″-20 or M6. Other models are available to purchase upon request as well as pressure tapped models. The PSP system package has several options for purchase. Depending on the size of the facility the system will be used in, some different optical kits may be appropriate. Additional LEDs and cameras can also be added to systems and seamlessly integrated. Building a system with the appropriate hardware for your facility is paramount to the success of the results.
CATEGORY

Temperature Sensitive Paint is an optical sensor for temperature measurements. A paint-like coating is applied to a surface and the fluorescence of the paint is monitored with a camera. The paint fluorescence is a function of the local temperature, and therefore, each pixel on the camera acts as a thermocouple.
CATEGORY

Binary paint is composed of two probes, a pressure sensor and a reference probe. The reference probe is used to compensate for errors caused by model displacement/deformation. It can also be used to compensate for temperature.
CATEGORY

The PSG-3 is a four channel digital pulse/delay generator used for controlling the timing of experiment parameters and can be used as an experiment master clock or externally triggered (or gated) by an external event. The PSG-3 replaces the PSG-2 in the ISSI product line. Pulse width, delay, repetition rate, and other timing parameters are controlled by a simple user interface (or also by any web browser interface) and communication is via Ethernet or USB. Features - Two dual-channel independently programmable pulse generators (each PSG-3 has 4 total channels). The PSG-3 can produce two separate frequency outputs either synchronously or asynchronously. - Four high-current TTL level outputs extend the utility of this generator by allowing it to drive low impedance loads (50 Ohms) such as solenoids and drive logic over long cable runs - Browser accessible HTTP-interface (internal web-server) - Remotely programmable through Ethernet or USB via simple software interface (or HTTP-based API) - Multiple timing bases (ns, us, ms) - Multiple PSG-3s can be cascaded to increase the number of channels - BNC inhibit input (TTL high level) to allow the PSG-3 to be gated by an external source - User application controlled or external signal triggering - Firmware upgradeability through USB - 50 MHz maximum trigger rate (20ns delay resolution) - Divide-by-N from 1-255 - Input Trigger Threshold 0.05-5.0V - Simple LabVIEW® integration Ideal for laser timing systems, automated testing, and precision pulse applications.