NW
Software
SoftwareInstrumentation

CLIAd

By ADSCIENTIS

Finally, in Liquid phase, the soft CLIAd allows to measure the adsorption of molecules with important sizes (surfactant, polymers…) so we can determine: - the adsorption isotherms - Langmuir model fittings - quantification of the amount of molecules irreversibly adsorbed Features common to the three software packages: - the acquisition of the experimental data (conditions and chromatograms) on two channels simultaneously and independently of each other - the treatment of these chromatograms in order to extract the necessary information to calculate the different physicochemical characteristics - the storage of the experiences and their results into a database - the possibility at any time to repeat an experience - the export of the data (chromatograms, results report) for processing in other softwares These software programs work under Windows and are commercialized with a acquisition data system from “National Instruments”. It is possible to adapt the software programs to the customer’s specific needs.

More from ADSCIENTIS

neuronIC

A Flexible Turnkey Solution for Commercial GC-to-Inverse GC Conversion that adapts to your budget and evolves with your needs. Adscientis' modular approach is adaptable to multiple GC platforms and can evolve from manual to fully-automated injections of up to 45 probes. Applies for powders, fibres, plates, films and liquids. neutronIC: the new standard in IGC science. Gas Chromatography, both "standard GC" and "Inverse GC", requires high-quality GC hardware components and accessories to insure high-quality, accurate, and repeatable data. Nucleus provides bi-directional digital communications compatibility with Thermo Fischer Scientific's TRACE 1610 (released in 2022) and prior TRACE 1310 models with alternate GC platform compatibility under development and available via special request. One or Two analytical channels running simultaneously. Operating T° range: ambient +3°C to 450°C. Modular and scalable (see options page for details). You will benefit from the modularity and flexibility of the neuronIC with a multitude of options available (ie TCD and other interchangeable detectors, headspace or liquid injectors, ss or glass column options with custom sizing options to minimize dead volume) to adapt to your available budget and vendor preferences with upgrade paths available on-demand as your needs change. Ambiant +3°C-450°C temperature range; Dead Volume minimized via variable length SS or glass columns; High throughput: 2 columns + 2 parallel channel injections; Interchangeable FID and TCD detectors for each channel. Introduced in 2017. NeuronIC is able to run two samples simultaneously. Hence, the determination of the dispersive component of the surface energy becomes easy and very fast. As an example, the measurement, at 25°C of γd s on two lactose monohydrate samples requires only 1200 seconds, i.e. 20 minutes (Fig. 1) to analyze two samples (packed in two columns) simultaneously, thus doubling the productivity of a single channel IGC. The Adscientis team is always available to provide technical support for your instrument, and scientifific expertise to assist with your most challenging applications.

i-Dilution

i-Dilution is specific to the measurements realized in gaseous phase at the infinite dilution conditions (IGC-ID). It allows the determination of: - the free energy change of adsorption (ΔGa) of each injected probe - the surface energy of the material (γsd) - the nanoroughness of the material - the surface acid-base character (ISP, Ka and Kb) Features common to the three software packages: - the acquisition of the experimental data (conditions and chromatograms) on two channels simultaneously and independently of each other - the treatment of these chromatograms in order to extract the necessary information to calculate the different physicochemical characteristics - the storage of the experiences and their results into a database - the possibility at any time to repeat an experience - the export of the data (chromatograms, results report) for processing in other softwares These software programs work under Windows and are commercialized with a acquisition data system from “National Instruments”. It is possible to adapt the software programs to the customer’s specific needs.

In-Pulse

Always in gaseous phase, but with probes injected at finite concentration (IGC-FC), In-Pulse has been developed to measure: - the desorption isotherms - the specific surface of the materials - their energetic surface heterogeneity Features common to the three software packages: - the acquisition of the experimental data (conditions and chromatograms) on two channels simultaneously and independently of each other - the treatment of these chromatograms in order to extract the necessary information to calculate the different physicochemical characteristics - the storage of the experiences and their results into a database - the possibility at any time to repeat an experience - the export of the data (chromatograms, results report) for processing in other softwares These software programs work under Windows and are commercialized with a acquisition data system from “National Instruments”. It is possible to adapt the software programs to the customer’s specific needs.

Nucleus

Nucleus: the CORE Conductor of neuronIC Instrumental Automation. Automates all GC and AutoSampler Operations. Comprehensive Database Management. Smart Peak End Detection. Supports High-Throughput Dual-Channel (Parallel) Injections. Built on 2 decades of IGC Consulting Experience. Application Driven Software Developed by IGC Experts. Guaranteed Reliable, Productive and Accurate Data. Adaptable High-Throughput Smart Automation. Employ Adscientis' NUCLEUS control software to automate GC+PAL robot and select custom IGC analysis modules.