By Photon etc
IMA is a hyperspectral microscope delivering spectral and spatial information from 400 nm to 1620... High-resolution spatial and spectral characterization at the microscopic scale

Hyperspectral Core Scanner The nCore is a multi-sensor scanning platform designed for drill core analysis. Whether deployed directly on-site or in a laboratory setting, the nCore offers unmatched versatility with modular configuration options tailored to the mining industry's needs. With the capability to integrate up to seven optical sensors, the nCore delivers an unparalleled map of the mineralogy landscape. Powered by Photon etc.'s proprietary hyperspectral imagers, it ensures precise and reliable performance for advanced mineral analysis, making it an indispensable tool for modern mining operations.
CATEGORY

Lecteur de plaques dédié à l’infrarouge à ondes courtes Lecteurs de plaques SWIR Photon etc. fait progresser le criblage à haut débit avec ClaIR™, un lecteur de plaques dédié à l’infrarouge à ondes courtes (SWIR, 900–1700 nm) et optimisé pour les nanocapteurs optiques et les nanomatériaux de prochaine génération. En opérant là où les matrices biologiques sont hautement transparentes, cette plateforme offre la sensibilité exceptionnelle requise pour cribler les capteurs à nanotubes de carbone à paroi simple (SWCNT) et suivre les éléments de reconnaissance moléculaire. ClaIR™ permet un balayage de zone automatisé par puits pour valider efficacement les nanocapteurs optiques dédiés aux cytokines inflammatoires, cartographier la localisation intracellulaire des capteurs en cytologie cancéreuse et accélérer la détection des biomarqueurs. ClaIR™ ClaIR est un lecteur de microplaques dans le NIR-II. Il enregistre la fluorescence de 900... Recherche sur les nanotubes de carbone
CATEGORY

L-EOS™ is an infrared push broom hyperspectral SWIR camera 0.9 to 2.5 µm. In contrast to traditional imaging techniques that capture images in only three spectral bands (red, green, and blue) per pixel, the L-EOS, a hyperspectral imaging system, captures hundreds of spectral bands stacked in each pixel, forming a hyperspectral data cube. This unique capability allows for highly detailed and comprehensive spectral analysis of the imaged objects. However, it’s worth noting that the L-EOS requires either motion from the object or the camera itself to acquire the data cube, as it creates an image by scanning one row at the time. Hyperspectral data cube provides more information than single band imaging, making it suitable for material sorting and in-depth analysis.
CATEGORY

TECHNICAL SPECIFICATIONS ZephIR 1.7x ZephIR 1.7s Sensor InGaAs FPA InGaAs FPA Sensor Format 640 x 512 640 x 512 Pixel size 15 μm 15 μm Spectral range 500-1700 nm 900 - 1700 nm Peak Quantum Efficiency 85 % 80 % Typical operability 99.9 % 99.5% Cooling Temperature @ 20°C ambiant -80 °C -80 °C Cooling method TEC + forced air TEC + forced air Typical Dark Current 125 ē/px/s 150 ē/px/s High Low High Med Low Typical Gain setting ( ē/ADU) 2.67 47.5 2.2 7.4 89 Typical readout noise ( ē) 22 135 28 75 315 Typical full well capacity (k ē) 8.5 250 27 110 1400 Readout modes CDS ITR STD ITR CDS ITR, CDS IWR, IMRO IWR Frame Rate 110 220 250 ROI Frame Rate Up to 500 Up to 900 Up to 4300 Integration time range from 1 μs to full well capacity from 1 μs to full well capacity Digitization 13 bits 14 bits Image Format 16 bits HDF5, FITS and TIFF 16 bits HDF5, FITS and TIFF Software PHySpec™ control and analysis software, SDK (C++, Python) PHySpec™ control and analysis software, SDK (C++, Python) Computer interface USB 3.0 and CameraLink™ USB 3.0 and CameraLink™ External control Trigger IN / OUT Trigger IN / OUT Ambient temperature range 10 °C to 35 °C 10 °C to 35 °C Power Supply 12V DC 12V DC Dimensions 169 mm x 130 mm x 97 mm 169 mm x 130 mm x 97 mm Weight 2.9 kg 2.9 kg Certification using cold target The ZephIR 1.7 is a high-end, scientific grade, 640 x 512 pixels resolution, InGaAs camera that marries performance with reliability. It has extremely low noise levels, high efficiency, and a rapid frame rate compatible with an external trigger. This is made possible by a combination of state-of-the-art control electronics and a four stage thermoelectric cooler (TEC) which can maintain an operating temperature as low as -80 °C. The TEC, in turn, uses forced air cool-ing which requires none of the maintenance of a water or liquid nitrogen chilled unit. The ZephIR 1.7 is one of the most sensitive and dependable InGaAs cameras on the market. ZephIR™ 1.7 » Compact » Highly reliable » Long lifetime » No maintenance » Low dark current » Low readout noise MAIN ADVANTAGES OF TEC + AIR SYSTEM Quantum efficiency presented at 25 °C. The cut-off wavelength shifts towards the blue by ~ 7nm for every 10 °C of cooling. Schematic of a thermoelectric device where the Peltier effect is used to generate heat flow between two materials. WHITE PAPER FIG. 1. Schematic of a thermoelectric device where the Peltier effect is used to generate heat flow between two materials. Thermoelectric (TE) stages are solid-state devices composed of two differents faces. Those stages uses Peltier effect to generate a temperature difference between the two faces. Semiconductors with different electron densities, n-type and p-type (see FIG. 1), are placed in series and connected with a conducting material on each side. The passage of an electrical current through the junction induces a heat flow from one face to the other, creating a cold and a hot side. The cold face absorbs heat which is carried to the other side where the heat sink is located. TE stages are usually connected side by side and sandwiched in two insulators. Water or air cooling is typically used to dissipate the heat accumulated in this process. The temperature that can be reached by TE coolers is related to the number of stages being used. Hence, for more effective cooling, it is possible to stack several stages. This is the case of Photon etc’s SWIR sensors, where four thermoelectric stages are cascaded together to lower the temperature. With four stages, a ΔT of 120 °C can be reached. This results in a detector operating temperature of -80 °C (193 K) with proper heat extraction, at 25 °C ambient temperature. OVERVIEW OF COOLING METHODS THERMOELECTRIC COOLING
CATEGORY