NW
Metrology
MetrologyInstrumentation

LUMiSizer 651

By L.U.M. GmbH

Current flagship model and bestseller: Multi-wavelength analytical centrifuge LUMiSizer 651.

More from L.U.M. GmbH

SEPView®

Your window to dispersion analysis & material testing SEPView® is a comprehensive database driven software solution that is used in device-specific versions with different capabilities tailor-made for the requirements of our different analysers. Whether you want to perform particle size measurements, stability analysis, determine creaming or sedimentation rates, predict shelf-life, examine flocculation and sedimentation consolidation, determine the degree of magnetization of your dispersed particles, or accurately calculate the particle density: with the help of SEPView you can do all this and more. SEPView controls the instrument and provides functions for data management, visualisation, analysis and result documentation. All information (calibration data, programmed measurement methods, comments, transmission profiles, settings etc) is stored in one database, no file management required. Fast access to validation and measurement results and sample information is guaranteed. Comparison of sample data from different measurements is easily achieved. Different program components are provided for the qualitative and quantitative analysis of the samples, e.g. - for the clarification - the Integral Transmission - for settling, creaming & consolidation - the Front Tracking - the PSA-Module for the calculation of the particle size distribution. The included animation tool displays the recorded measurement data with programmable playback parameters for easy recognition & identification of complex separation phenomena. Standard database functions like import & export of measurements and results, filtration of database content by various criteria, user and database administration are supported by SEPView. The program supports different languages and different systems of units. The modular and object oriented design of the software provides easy extension and customizing opportunities on customer's request, i.e. for special R&D or QC tasks. SEPView complies to CFR 21 Part 11 for special R&D or QC tasks. 15 December 2021: LUM devices not affected by CVE-2021-44228 - referred to as Log4Shell Currently a security vulnerability in the widely spread Java component log4j is investigated and mitigated by various vendors. Today, we would like to inform you that LUM devices as well as all versions of the Software SEPView do not use that component nor Java technology. Therefore they are not affected by this vulnerability. You might want to carefully check workstations and server under your administration, running SEPView, for independently installed services and applications regarding the issue. Highlights - Windows-based with Ribbon User Interface - plug and play, pack and go - Simultaneous instability index analysis for up to 12 samples in real-time - Individual user customization - Full SOP concept (creation, capture, data analysis) - Tools: - Time lapse measurement replay - Dispersion fingerprint - Instability index - Clarification - Phase separation - Sedimentation and creaming velocities - Particle density and size distribution - First derivative of integral transmission - Multi-wavelength extinction ratio (LUMiReader) - Multi-wavelength particle size analysis (LUMiReader) - Complies with 21 CFR Part 11

LUMiSizer®

Exceptional possibilities The LUMiSizer® masters these kinds of analyses - Particle size distribution - Droplet size distribution - Separation velocity - Sauter Diameter - Particle magnetization - Density distribution - Hansen Solubility/Dispersibility Parameters - Sedimentation - Creaming - Agglomeration - Flocculation - Coalescence - Emulsification - Dispersibility - Shelf-life (comparative & predictive) - Direct, accelerated stability analysis Test up to 12 samples simultaneously Obtain unique "fingerprints" for your samples Optimize your dispersions Achieve stability measurements quickly and directly Measure particle size even at high concentrations Obtain particle densities Compare and predict the shelf life Differentiate between the different instability mechanisms Measure samples within a wide temperature range (4 ˚C to 60 ˚C) Analyze (highly) concentrated samples (up to 90%) LUMISIZER® – See and understand your complete sample Analyze aqueous, non-aqueous, Newtonian, non-Newtonian systems - the choice is yours. The LUMiSizer is an evolutionary development based on the LUMiFuge platform with some significant additional capabilities that instantaneously measures the extinction (space- and time-resolved) of the transmitted light across the entire length of your sample using the STEP-Technology®. Because of an enhanced optical system, the LUMiSizer lets you analyse particle and droplet velocity distributions for creaming and sedimentation phenomena without the need of any material data and performs particle sizing (ISO 13318- 2). Run 12 samples at a time under a wide range of viscosities, temperatures, and real-world concentrations. The LUMiSizer is the only instrument in the world that allows you to obtain particle velocity distributions without having to know any material constants. Analyse aqueous, non-aqueous, Newtonian or non-Newtonian systems – the choice is yours. You can measure the effects of concentration, shape, and colloidal forces on your particle size distribution and stability. You can create your own hindrance functions or work with published ones. Either way, you can accurately measure and predict ideal and non-ideal particle behaviour. The exceptional precision of the system ensures that all particle size fractions are measured in a short time. Immediate data collection across the entire sample ensures exceptional results, whereby you can measure wide particle size distributions, determine non-idealities and gain the ability to resolve multimodalities. Think of the LUMiSizer as a LUMiFuge on steroids, a direct stability and particle size analyser forged into one. It can do all the things the LUMiFuge can, only more. In addition to measuring stability directly and making shelf life prediction, you can also distinguish between flocculated and nonflocculated dispersions and measure particle size distributions using the highest industry norms and regulations. Several wavelengths are available, allowing for a broad particle size spectrum coverage. Comes with state-of-the-art software SEPView®. The LUMiSizer comes certified, factory precalibrated and is ready-to-go. International norms and guidelines The LUMiSizer® meets the following standards ASTM STP1527 CFR 21 Part 11 DIN 51817 GB/T 42342.2 GB/T 41316 ISO 13318-1 ISO 13318-2 ISO 18747-1 ISO 18747-2 ISO 20427 ISO/TR 13097 ISO/TR 18811 ISO/TS 22107 JIS Z 8823-1 NF X31-107 WHO Technical Report Series No. 962, Annex 3 Material overview The following materials can be analyzed with the LUMiSizer Abrasives Beverages Carbon black Carbon nanotubes Ceramics Color pastes Cosmetics & personal care Fine chemicals Foams Fuel cells Graphenes Inks Nano-dispersions Pharmaceuticals Polymers Slurries Wastewater and many more materials... Multi-wavelengths Separation and consolidation phenomena By integrating two different light sources into one device, LUM combines the functionalities of both individual versions of the near-infrared (NIR) and blue LUMiSizer in the new multi-wavelength LUMiSizer 65x. The multi-wavelength LUMiSizer for the rapid characterization of the most diverse demixing and consolidation phenomena as well as the quantification of the velocity and particle size distribution according to ISO 13318 is predestined for users with changing challenges, such as top research institutes, universities and industrial development departments. In nanotechnology, two separate LUMiSizers were previously required for particle characterization of e.g. nanosilica (blue device), core-shell samples... Download & Technical Data Technical Data LUMiSizer® Accelerated phase separation 6–2300 times compared to gravity Particle size distribution 20 nm to 100 µm (20 nm to 50 μm rec. with blue wavelengths) Consolidation measurements concentrated dispersions and sediments Observation time 1 s to 99 h Conformity ASTM STP1527, CFR 21 Part 11, DIN 51817, GB/T 42342.2, GB/T 41316, ISO 13318-2, ISO 18747-1/2, ISO 20427, ISO/TR 13097, ISO/TR 18811, ISO/TS 22107, JIS Z 8823-1, NF X31-107, WHO Technical Report Series No. 962, Annex 3 Samples up to 12 simultaneously Volume 0.05 ml to 2.0 ml Concentration 0.00015 Vol % – 90 Vol % Density up to 22 g/cm³ Viscosity 0,8 - 10 8 mPas Particle size 10 nm to 1000 µm Light source multi-wavelength Temperature control 4 °C to 60 °C, +/– 1K Cells different material and optical path Dimensions (WxHxD), weight 37 cm x 27 cm x 60 cm, 40 kg Power supply 100 V | 120V | 230 V, 50/60Hz

LUMiFuge®

The only direct and accelerated stability analysis Up to 8 samples simultaneously THE LUMiFuge® MASTERS THESE KINDS OF ANALYSES - Direct accelerated stability testing - Comparative & predictive shelf-life analysis - Surfactant efficiency - Destabilization phenomena - Phase separation - Solidosity - Clarification - Dewaterability, consolidation - Segregation - Creaming rate - Sedimentation rate - Magnetization - Emulsifier efficiency - Instability index Measure up to 8 samples simultaneously Physical stability - compare and predict Deliver fast and direct stability measurements Compare and predict shelf life Analyse magnetic particles Work with high sample concentrations and a wide range of temperatures Flocculant and demulsifier selection Needs no material constants Immediately see and understand your complete sample top to bottom Optimize your dispersion Measure and differentiate various degrees of destabilization phenomena Use disposable cells Quick and easy to use LUMiFuge® – Fast and direct stability measurements Eight samples simultaneously thanks to special powerful LED elements The LUMiFuge is an analytical centrifuge that measures instantaneously the extinction of transmitted light across the full length of your sample using the STEP-Technology®. It is the only instrument in the world that enables you to perform physically accelerated, direct and efficient stability testing and ranking of your formulations. It features an advanced optical system enabling multi-sample analysis at user defined speeds, light intensities and temperatures. The optical blocks consist of high-powered special light sources of different wavelengths. The parallel light illuminates the whole sample from top to bottom. Even the smallest changes across the entire sample height are detected by a sensor featuring high optical and spatial resolution. Immediate data collection ensures the ability to measure everything that occurs in your sample; no matter how simple or complex. There is no need to dilute or to know any material constants; just input your samples and you have your results. By looking at the fingerprint patterns of the whole sample, you can classify and understand the causes of instability, e. g. creaming, sedimentation or flocculation, as well as measure and rank stability. Use this knowledge to develop new formulations and optimize current ones easily. You can analyse up to eight different samples simultaneously in a wide range of viscosities and virtually any concentrations at operator preset temperatures (+/- 0.5 K). A truly one-of-a-kind feature also allows you to measure the separation behaviour and magnetic properties of micro- and nano particles in variable superimposed orthogonal or parallel magnetic fields in addition to the conventional sedimentation field. This provides you with the unique opportunity to analyse magnetic nano- and microparticles. Comes with state-of-the-art software SEPView. The LUMiFuge comes certified, factory pre-calibrated and is ready-to-go. THE LUMiFuge® MEETS THE FOLLOWING STANDARDS ASTM STP1527 CFR 21 Part 11 GB/T 41316 ISO 18747-1 ISO/TR 13097 ISO/TR 18811 MATERIAL OVERVIEW The following materials can be analyzed with the LUMiFuge® Abrasives Beverages Carbon black Carbon nanotubes Ceramics Color pastes Cosmetics & personal care Fine chemicals Foams Fuel cells Graphenes Inks Nano-dispersions Pharmaceuticals Polymers Slurries Wastewater and many more materials... Download & Technical Data Technical Data LUMiFuge® Accelerated phase separation 6–2300 times compared to gravity Consolidation measurements concentrated dispersions and sediments Observation time 1 s to 99 h Conformity ASTM STP1527; CFR 21 Part 11; GB/T 41316; ISO 18747-1; ISO/TR 13097; ISO/TR 18811 Samples suspensions, emulsions, suspo-emulsions, sludges, slurries Channels up to 8 simultaneously Volume 0.05 ml to 2.0 ml Concentration 0,00015 Vol % - 90 Vol % Density up to 22 g/cm³ Viscosity 0.8–10 8 mPas Light source NIR, special versions Temperature control 4 °C to 60 °C, +/– 1K Cells different material and optical path Dimensions (WxHxD), weight 37 cm x 27 cm x 60 cm, 40 kg Power supply 100 V, 230 V; 50/60Hz

LUMiReader® PSA

THE LUMiReader® PSA MASTERS THESE KINDS OF ANALYSES - Particle size distribution - Direct real-time stability testing - Dispersion classification (Fingerprinting) - Separation velocity distribution - Sauter diameter distribution - Droplet & particle density distribution - Hansen dispersibility parameters - Turbidity index - Asphaltene separability number - Flocculation & coalescence - Sedimentation & creaming rate - Clarification rate - Accelerated gravity separation (Boycott effect) - Comparative & predictive shelf-life analysis See & understand complex dispersion processes instantly Direct stability testing Obtain volume PSD without refractive indices and without assumption of spherical & homogeneous particle shapes Get separation velocity distribution (sedimentation and creaming) Optimize sensitivity by simultaneous multi-wavelength approach Determine hydrodynamic particle density based on ISO 18747-1 Cloud Point Determination Monitor aggregation and crystallization Calculate density of your dispersed particles Investigate temperature effects up to 80 °C Differentiate between the various instability mechanisms Handle any dispersing media: water, oils, organic solvents Uses disposable cells, customizable LUMiReader® PSA – What the naked eye cannot see Maximum comparison precision and no material data such as viscosity or density required The LUMiReader PSA instantaneously measures the extinction profile of the transmitted light across the entire length of your sample using the STEP-Technology®. It may be recalculated in terms of clarification and particle concentration. Each LUMiReader contains an optical block and temperature control element. In addition, the specially designed PSA module also opens new horizons for high resolution particle sizing and allows you to measure the velocity distribution of separating particles. There is no need for you to know any material constants such as viscosity or density. Our proprietary design ensures that the light strikes the sample across its entire height, ensuring maximum optical sensitivity and reproducibility. The optical detector assembly features micro-scale spatial resolution capable of accurately measuring even the smallest local changes instantaneously across the entire sample height. This design eliminates the time-consuming and less accurate task of scanning your sample, allowing you to capture even very fast micro-changes occuring in your dispersion without mechanical vibration. The LUMiReader also uses a patented tilt technology based on the Boycott effect. The well-known principle allows accelerated, real-time stability testing at gravity by tilting the sample from its normal upright position. The magnitude of acceleration (up to 10 times) depends on geometric factors, such as tilt angle, vial dimensions, and sample type. Analyse in a wide range of viscosities, temperatures, and concentrations. With the advantage of looking at the entire sample from top to bottom instantaneously, you can observe and understand different stability/instability phenomena concurrently; for example, creaming, sedimentation coalescence, aggregation and flocculation at original product concentration. Comes with state-of-the-art software SEPView. The LUMiReader comes certified, factory pre-calibrated and is ready-to-go. International norms and guidelines THE LUMiReader® PSA MEETS THE FOLLOWING STANDARDS ASTM D7827 CFR 21 Part 11 ISO 13317-1 ISO 13317-5 ISO 18747-1 ISO 20427 ISO/TR 13097 MATERIAL OVERVIEW The following materials can be analyzed with the LUMiReader® PSA Abrasives Asphaltenes Carbon black Ceramics Crude oil Fine chemicals Food Gas oil Ink Petrol Pharmaceutical dispersions Polymers Sludges Slurries and many more materials. MULTI-WAVELENGTHS Determination of the volume-weighted particle size distribution The LUMiReader PSA allows for the first time the determination of the volume based particle size distribution (ISO 13317) for emulsions and suspensions, without the necessity of knowing the refractive index or software input and no assumption regarding particle shape and shape distribution. This opens new horizons for the characterization of industrial products, where above parameters are often not available or not applicable. LUM’s patented STEP-Technology, the measurement of Space and Time-resolved Extinction Profiles, was extended to an unique new multi-wavelength approach: alterations of ratio of transmission at different wavelengths monitors any particle or droplet size variation over product life without sizing particles itself. Giving particle size distribution (ISO 13317), separation velocity distribution and hydrodynamic particle density in addition to the direct stability result according to ISO TR 13097, the new LUMiReader PSA is one instrument for the comprehensive understanding of complex industrial products in an easy way. PARTICLE SIZE AND DENSITY ANALYSIS The specially developed PSA module The specially designed PSA-module allows you to measure the velocity distribution of separating particles. There is no need for you to know any material constants such as viscosity or density. Velocity Distribution Qv(v), qv(v) Direct measurement, no calibration / no material properties Always available - fast information for quality control Qualitative information about particle size and polydispersity Intensity Weighted Particle Size Distribution QInt(x), qInt(x) Quantitative information about particle size distribution Volume Weighted Particle Size Distribution Q3(x), q3(x) Quantitative information about particle size and volume fraction of each class Conversion into mass or number distribution Download & Technical Data Technical Data LUMiReader® PSA Accelerated phase separation up to 10 times at gravity (acceleration depends on sample properties) Particle size distribution range< 500 nm to 300 µm Observation time 0.5 s to unlimited Conformity ASTM D7827; CFR 21 Part 11; ISO 13317; ISO 18747-1; ISO 20427; ISO/TR 13097; ISO/TR 13097 Samples suspensions, emulsions, suspo-emulsions, sludges, slurries Channels 1 sample Volume 0.2 ml to 4.0 ml Concentration 0.00015 Vol% – 75 Vol% Density up to 22 g/cm³ Particle size 200 nm to 2000 µm Light source multi-wavelength (NIR, red, blue) Working temperature range4 °C to 80 °C (+/- 0.03 K) Temperature stability0.4 K Temperature uniformity (in sample)0.2 K Ambient temperature 5 °C to 40 °C Tilt vertical (0°) to 5°, 10°, 15°, 20°, 25°, 30° Cells different materials, optical path 1 mm to 10 mm Dimensions (WxHxD), Weight 29 x 24 x 44 cm / 11 kg Power supply 24 V, Adapter (100 V to 240 V) included Data interface Network adapter