Case of MagLynx series PurePrep 96 disposable tip combs. Each case includes 50 total 96-well tip combs. Part Number: MKS-96-TCS-1 Minimum Quantity: 1 case Part Number: MKS-96-TCS-P Minimum Quantity: 42 cases

High-performance automation designed to meet the workflow challenges of today’s life science lab. Value-driven features allow configuration of the ideal system for your application. Proudly designed and built in the U.S.A. AUTOMATED PIPETTING. DONE SMARTER. The world’s only automated liquid handler offering direct volumetric measurement of each and every liquid transfer. Lynx with award-winning Volume Verified Pipetting technology (VVP®) takes the guesswork out of automated 96, 24 & 8 multi-channel liquid handling, calculating in real-time the actual volume of fluid entering and leaving each and every tip. VVP supports LLD for any liquid type with ‘live’ pipetting Dx for ‘on-the-fly’ error recovery. A final QC validation report documents all pipetting events and verifies if automated methods were performed successfully. Confidence in knowing that precious samples & expensive reagents were not wasted. INVALUABLE! Removing the uncertainty & achieving a new level of pipetting performance and compliance in your laboratory automation workflow. PRICELESS! Complex Pipetting Made Easy - The world’s only automated liquid handler offering independent volumes in a multi-channel head. - Lynx with VVP technology enables simultaneous control of different volumes for each & every channel on 24VVP and 96VVP multi-channel pipetting tools. - Makes quick work of commonly performed microplate pipetting routines - Normalizations under 45 seconds! - Serial Dilutions up to 11x faster! - DOE/Formulations up to 20x faster! - Pooling or Hit Picking 11x more efficient 24/96-well plates; vs. competing 8×1 mL channel variable-volume automated pipetting arm LARGE VOLUMES AT HIGH THROUGHPUT. The world’s only automated liquid handler offering 5 mL volumes in a 24-channel head. Lynx with the 24VVP tool supports large volume applications with 24 variable-volume control and a broad dynamic pipetting range, from 50 μL to 5 mL. Increases speed and efficiency for large volume workflows: - Liquid Biopsy Sample Distribution/Re-arraying 5x – 12x faster vs. competing 96×1 mL channel uniform volume pipetting arm vs. competing 8×5 mL channel variable-volume automated pipetting arm SIMPLIFY LIQUID CLASSES. The world’s only automated liquid handler that simplifies liquid class development. With VVP technology, Lynx can pipette any liquid type – from organics to aqueous to complex mixtures without tedious optimization of parameters for each liquid type or volume range. Reduces validation efforts for assays and adoption of new protocols - LC Development/Recalibration ZERO TIME! for liquid class development or re-calibration to new assays or protocols vs traditional air or liquid-based pipetting technology
CATEGORY

Instrument Control Software Software Designed For The User Method Manager 4.0, Instrument Control Software, with it's modular architecture, combined with new VVP & ST tools, gives each user the ability to take advantage of an easy to use, highly flexible liquid handler right out of the box. SIMPLIFIED INSTRUMENT CONTROL SOFTWARE - Streamlined method programming enables rapid method design and shorter learning curves - No need to attend week-long training courses – complete training is conducted on-site in your lab, with a dedicated specialist available for post-install remote support - Custom method templates for fast programming and implementation of new protocols FULL PIPETTING DIAGNOSTICS & SAMPLE TRACKING - Access VVP volumetric measurement data for increased pipetting confidence - Conduct 'on-the-fly' LLD and pipetting diagnostics to ID and resolve common pipetting errors (ie bubbles/clogs/short sample/no sample) - Full recording of all instrument actions offers a complete audit trail for enhanced process security FLEXIBLE INSTRUMENT INTERFACE - No-nonsense interface for controlling all pipetting and gripping functions - API pathway for communication with third-party devices - Modular framework supports integration of add-on software and applications From simple plate stamping routines to the more complex, MM4.0 provides an efficient, straightforward approach to method programming for many workflows. Method Manager Integrated VVP Example Applications Below are some of the most requested questions concerning Method Manager and how it handles certain applications. With the implementation of the VVP tools, new and novel applications are now available. Applications like; Whole Plate Normalization, Whole Blood Sample and Plant/Seed Homogenate Transfers with clog/clog individual well diagnostics and on-the-fly correction, whole plate pooling with all 96 tips, selective high throughput hit picking are all now possible.
CATEGORY

Seamless core swapping. Increased throughput. Ultimate flexibility. The MCPA tools are a versatile suite of interchangeable head tools designed to seamlessly integrate with the Standard Technology (ST) system. With just two simple commands—load and unload—the system effortlessly swaps between head tools, eliminating the need for recalibration between swaps. On-the-fly tool changes within a method transform the ST system into a modular, all-in-one automation powerhouse. Available MCPA tools include 24, 96, and 384 ST pipetting heads, 24 and 96 magnetic rod heads for automated on-deck purification, and positive pressure tools, offering unparalleled flexibility and precision for diverse applications. - Practical Multi-Application: Perform liquid transfers, mag-bead purification, sample filtration, and more. - Seamless Core Swapping: On-the-fly tool exchange within ~45 seconds. - Extended Walkaway Time: No need for third-party device integration or manual intervention. - Increased Throughput: Reliable, uninterrupted workflow saves time and enhances efficiency. - Large Volume Handling: The only liquid handling platform offering a 5 mL 24 pipetting head and a 24XL magnetic rod head.
CATEGORY

High-Throughput LNP Formulation Screening on Lynx VVP Generate LNPs directly on Lynx VVP with the LNP Screening Array, combining microfluidic formulation with automated liquid handling. 100+ Formulations Per Hour Run broader screens without slowing development. 10× Faster Than Traditional LNP Instruments Generate formulated LNPs in seconds. <25 µL Dead Sample Volume Preserve valuable lipid and RNA inputs for more screening. Particle Quality That Holds Up in Screening Testing on Lynx VVP produced small particle size and PDI suitable for formulation development. Increasing pressure from 225 mbar to 1000 mbar reduced Z-average diameter from 81.9 nm to 49.6 nm while maintaining low PDI across the tested pressure range. LNP Screening Array Specifications Format: SLAS Microplate Micromixers per array: 8 Dead volume per mixer: <25 µL Output volume per mixer: Up to 1 mL Fluidic resistance ratios: 3:1 Turnaround: Ships in 1 week
CATEGORY