NW
Coatings
CoatingsApplications

Screen Layer Part A (SCRA-xxx)

By Innovative Scientific Solutions Inc.

Recommended Use: Paint Signal Word: WARNING Hazard Statement: Flammable Liquid, Target Organ Effect Target Organs: Central nervous system Precautionary Statements: Keep this flammable material away from heat, sparks, flames, or other sources of ignition. The fumes of this product are harmful and should not be inhaled. This product is not to be consumed. Hazardous Components Information: Epoxy Resin 10% 25036-25-3 Titanium Dioxide <10% 13463-67-7 Methyl Ethyl Ketone <10% 00078-93-3 Xylene 30% 01330-20-7 First Aid Measures: - Inhalation: Remove person to fresh air. Seek medical attention. - Skin Contact: Wash off with soap and water. Seek medical attention. - Eye Contact: Flush eyes with water for 15 minutes. Seek medical attention. - Ingestion: Seek medical attention. Fire Fighting Measures: - Flammable Properties Flash Point: 12 o C (54 o F) closed cup Ignition Temperature: No data available. - Extinguishing Media Dry chemical or CO2 - PPE for Firefighters Self-contained breathing apparatus Further Information Use water spray to cool unopened containers Accidental Release Measures: - Personal Precautions: Avoid breathing vapor or mist. Ensure adequate ventilation. Remove all sources of ignition. Evacuate personnel to safety. Vapor can accumulate to form explosive concentrations especially in low areas. - Environmental Precautions: Avoid discharge into the environment by preventing the product from entering sewer drains or storm drains. - Methods for Cleaning Up Spills: Use noncombustible absorbent material such as vermiculite or sand to absorb the spill. After the absorbent is dry dispose of it in accordance with local regulations. Handling and Storage: The container should be stored in a cool, dry place away from sources of ignition (sparks, flame, etc.). Avoid areas where static charge can build which could ignite the product (carpet). Store this product away from strong bases, oxidizing, or reducing agents. Exposure Control Personal Protection: - Respiratory: Use full face respirator that is for organic vapors and is properly fitted to the end user if the product is used where ventilation is unavailable. Self-contained breathing apparatus or a suitable exhaust hood are recommended. - Hand Protection: Use protective gloves. - Eye Protection: Safety glasses. - Hygiene Measures: Practice good industrial hygiene and safety by washing hands thoroughly with soap and water after using this product. Physical and Chemical Properties: Appearance: White Milky Liquid Odor: Characteristic Odor Threshold: No data Vapor Pressure: No data Vapor Density: No data pH: N/A Melting Point: -29 o C (-20 o F) Boiling Point: 100-103 o C (212-217 o F) at 760mmHg Flash Point: 12 o C (54 o F) Evaporation Rate: No data Ignition Temperature: No data LEL: 1.0 UEL: No data Auto Ignition Temperature: No data Decomposition Temperature: No data Viscosity: No data Partition Coefficient: N/A Specific Gravity: 1.114 Water Solubility: No data Stability and Reactivity: - Storage: Stable under recommended storage conditions. - Conditions to Avoid: Heat, flames, sparks - Materials to Avoid: Strong bases, oxidizing or reducing agents - Hazardous Decomposition Products: carbon oxides - Hazardous Reactions: Can form an explosive mix with air Toxicological Information: - Acute Toxicity Epoxy Resin LD50 Oral Mouse: 5100mg/kg MEK LD50 Rat: 2740mg/kg - Chronic Exposure Prolonged occupational overexposure can damage the brain and central nervous system. - Signs of Over Exposure Central nervous system depression, drowsiness, dizziness Ecological Information: - Elimination: No data available - Ecotoxicity: No data available. - Additional Information: Unprofessional or irresponsible use or disposal of this product could pose a long term danger to the environment. Disposal Considerations: Observe all local waste disposal regulations and contact a licensed, professional waste disposal service to dispose of this product. Transport Information: Proper Shipping Name: Screen Layer Paint Part A (SCRA-xxx)* USDOT Hazard Class: 3 Flammable Liquid UN1263 Packing Group II *xxx is the volume of product in the package. Regulatory Information: OSHA Hazards: Flammable Liquid, Target Organ Effect Additional Information: The above information is believed to be correct by ISSI personnel based on present knowledge but is intended solely as a guide. Always take precautions and behave professionally and responsibly when handling chemicals. ISSI assumes no liability whatsoever for improper handling, storage, or utilization outside of the intended use of this product.

More from Innovative Scientific Solutions Inc.

Educational PSP/TSP System

The educational PSP/TSP system provides everything needed for new users to get started using PSP and TSP. This system provides high spatial resolution, excellent dynamic range, but lower data capture rates than our higher-end systems. For applications where time in the wind tunnel is not a critical issue, it represents an excellent cost/performance trade-off. This system provides full capability for undergraduate demonstrations, training, and laboratory exercises. It will support all but the most demanding graduate and faculty research programs requiring distributed pressure and temperature measurements in wind tunnel environments. The system employs proven ISSI LED technology for excitation of the luminous probes in the paints. The camera is based on a color CCD sensor, eliminating the need for a filter wheel when using bi-luminophore paints. The OMS-Lite software package is easy to use and fully supports the educational and research capabilities of the PSP/TSP system. Standard System Components: - Color CCD Camera: 12 bit, 1.9 Megapixel color CCD camera with Gigabit Ethernet connectivity - LM2X-DM-400 LED Array: High-power UV LED module with TTL control - PSG-3: Pulse/delay generator for instrument control and synchronization - Parbolic Reflector and Diffuser: Focuses output of LM2 series LEDs from 120- to 40-degrees giving 2-3 times increased focused output. - PSP/TSP Starter Kit: PSP starter kit including beginner paints in spray cans, Binary FIB and FIB Basecoat with HVLP paint gun and airbrush with compressor and fittings. - Optical Kit: This kit contains all lenses and filters needed to get started using PSP and TSP. Available with c-mount or Canon® EF mount lenses. - ProAcquire and OMS-Lite: Data acquisition and data reduction software. Test models used in the lab experiments are provided with the the educational PSP/TSP system. An aluminum delta wing and NACA 0012 airfoil model are included with the system along with the mounting hardware to install them for either 1/4″-20 or M6. Other models are available to purchase upon request as well as pressure tapped models. The PSP system package has several options for purchase. Depending on the size of the facility the system will be used in, some different optical kits may be appropriate. Additional LEDs and cameras can also be added to systems and seamlessly integrated. Building a system with the appropriate hardware for your facility is paramount to the success of the results.

TSP (Temperature Sensitive Paint)

Temperature Sensitive Paint is an optical sensor for temperature measurements. A paint-like coating is applied to a surface and the fluorescence of the paint is monitored with a camera. The paint fluorescence is a function of the local temperature, and therefore, each pixel on the camera acts as a thermocouple.

Binary paint

Binary paint is composed of two probes, a pressure sensor and a reference probe. The reference probe is used to compensate for errors caused by model displacement/deformation. It can also be used to compensate for temperature.

PSG-3

The PSG-3 is a four channel digital pulse/delay generator used for controlling the timing of experiment parameters and can be used as an experiment master clock or externally triggered (or gated) by an external event. The PSG-3 replaces the PSG-2 in the ISSI product line. Pulse width, delay, repetition rate, and other timing parameters are controlled by a simple user interface (or also by any web browser interface) and communication is via Ethernet or USB. Features - Two dual-channel independently programmable pulse generators (each PSG-3 has 4 total channels). The PSG-3 can produce two separate frequency outputs either synchronously or asynchronously. - Four high-current TTL level outputs extend the utility of this generator by allowing it to drive low impedance loads (50 Ohms) such as solenoids and drive logic over long cable runs - Browser accessible HTTP-interface (internal web-server) - Remotely programmable through Ethernet or USB via simple software interface (or HTTP-based API) - Multiple timing bases (ns, us, ms) - Multiple PSG-3s can be cascaded to increase the number of channels - BNC inhibit input (TTL high level) to allow the PSG-3 to be gated by an external source - User application controlled or external signal triggering - Firmware upgradeability through USB - 50 MHz maximum trigger rate (20ns delay resolution) - Divide-by-N from 1-255 - Input Trigger Threshold 0.05-5.0V - Simple LabVIEW® integration Ideal for laser timing systems, automated testing, and precision pulse applications.