
By Institute of Polymer Materials and Technology
To measure surface and interfacial tension by the methods of Wilhelmi plate and tearing off the ring. The container with the test liquid is brought into contact with the plate or ring, then lowered and the maximum tearing force is fixed. Specs: - Surface tension measurement range 1-1000 mN / m; - Surface tension measurement accuracy ± 0.1 mN / m; - Weight measurement frequency 1 Hz.

Fluorescence module with extended spectrum: Equipped with a set of replaceable filters (G, B, BV, V, U), providing the ability to work with a wide range of fluorochromes for a variety of research tasks. Powerful light source: A mercury lamp (100 W) with an external power supply ensures the bright and stable illumination required for effective fluorescence microscopy. The radiation shield ensures safe operation of the user. High-quality optics: A set of semi-apochromatic fluorescent lenses, adjusted to infinity (4x, 10x, 20x, 40x), provides excellent clarity, contrast and minimal image aberration. Professional visualization and documentation: The built-in 10-megapixel camera allows you to take high-resolution photos and videos (up to 3584×2748 pixels). Video recording at up to 27 frames per second provides smooth and detailed visualization of dynamic processes.
CATEGORY

Monowave 50 microwave reactor for organic synthesis is a precision instrument designed for conducting chemical reactions using microwave radiation. It is optimized for the synthesis of organic compounds, offering extensive control and optimization of reaction conditions. Technical Specifications: - Filling volume: Up to 6 ml - Maximum working pressure: 20 bar - Maximum temperature: 250 °C - Microwave power: 315W - Vial material: Borosilicate glass (provides high chemical resistance) - Cap material: Silicone (for reliable sealing) - Seal material: Teflon (chemically inert, ensures a tight seal at high temperatures and pressures)
CATEGORY

A professional modular conductivity meter 856 Conductivity Module meets all the requirements of GLP and FDA Specs: - Conductivity, measuring range 0 – 500 mS; - Conductivity, resolution of 4 significant decimal places - Conductivity, measurement error Range 1..5 μS: ± 1%; ± 1 digit;Range 5..50 μS: ± 0,5%; ± 1 digit; Range 50..500 μS: ± 0,5%; ± 1 digit;Range 0.5..5 mSm: ± 0.5%; ± 1 digit;Range 5..50 mSm: ± 0.5%; ± 1 digit;Range 50..500 mSm: ± 1%; ± 1 digit; - Temperature, measuring range -40°C – +150°C - Temperature, resolution 0.1°C, - Temperature, measurement error ± 0.2°C.
CATEGORY

Automatic titrator 905 Titrando can solve any problem of automatic potentiometric titration Specs: - Titration to the end point (SET); - Monotonic titration to the point of equivalence (MET); - Dynamic titration to the point of equivalence (DET); - Measurement with ion-selective electrodes; - Touch-and-Go – titration by pressing one button; - iTrodes – intelligent electrodes with automatic recognition when connected to a titrator; - Wide possibilities of automation of titration and sample preparation.
CATEGORY