NW
Product EngineeringResearch & Engineering

Indirect Fluid Mixing System

By Bartels Mikrotechnik

How This Microfluidic System Works This indirect fluid mixing system with a mixing chip enables sample injection, mixing and bi-directional movement via air pressure pump. Ideal for precise mixing and sample handling in diagnostics and research. The Essential Components - 3 x The Bartels Pump | BP7 – Mounting - 3 x Mounting Frame - 3 x Pump driver - 2 x mp-damper - 2 x Flow sensor - 2 x NC 2/2 valve - 2 x 3/2 valve - 1 x mp-valvedriverS - 1 x mp-valvedriverT/M - 1 x mp-bt Bubble Trap - 1 x Mixing Chip - Tubing: Tygon / Silicon - 3D printed Chip - Customized PCB material - Casing Customize Your Fluidic System Software Electronic Interface: USB Bluetooth Wifi RS485 Interface Fluidic Interface: Festo QS Upchurch connectors made from PEEK Barb connectors Luer connectors Fluid Routing Options: Tubing Fluidic Interface/Manifold/Chip Pricing Overview Turnaround Time: 4 – 6 weeks Option I Individual Order – initial budget required – 1 Custom Engineering 20.000 € 2 1 x Developed System 2.000 € OR Option II Blanket Order – no initial budget required – 1 100 x Developed Systems including Custom Engineering Detailed process of designing and applying solutions 2.200 € per System