Bookable cleanroom or nanofab facility time.
Showing all 102 providers

Government & National Laboratories · 1–10 employees · France
1 listed under this category
CRHEATEC Technology Platform
CRHEATEC and CRHEACAM platforms: Through these two platforms, CAT offers a range of techniques dedicated to cutting-edge structural characterization of materials with various techniques and micro- and nano-fabrication in clean rooms. The center has historical expertise in III-nitride materials, ZnO, and SiC, but is also developing expertise in new materials, particularly 2D and perovskites. The resources implemented within the CAT are accessible to researchers from the laboratory as well as to external laboratories and companies.

Contract & Professional Service Providers · 51–200 employees · United States
25 listed under this category
Gene Therapy Cleanroom Design-Build
Clinical Stage and Volume Production Cleanrooms AdvanceTEC the industry leader of integrated cleanrooms for gene therapy clients across the technology spectrum. Gene therapy innovators using technologies such as CRISPR, GTMP, SCTMP and TEMP have benefited from AdvanceTEC's cleanroom design-build expertise. Our in-house team of segment experts are skilled in process integration of single use disposable equipment platforms for clinical stage and volume manufacturing applications. Speed, accuracy, and certainty of cost & schedule are hallmarks of AdvanceTEC's cleanroom integration and our delivery of total performance for you. Gene therapy cleanrooms are purpose-built facilities customized to the unique processes they enable. While every gene therapy cleanroom is different, there are common considerations that span the various gene therapy applications and technology platforms: Gene Therapy Cleanroom Design Considerations - MAL (Material Airlocks) / PAL (Personnel Airlocks) - Door interlocking and personnel flow patterns - Pressure cascades - Process equipment configuration and access - HVAC configurations and air flow segregation - Down flow booths or LAF (laminar air flow) modules - Low wall returns - Process distribution - Environmental monitoring - ISO classification, temperature & humidity - Viewing, monitoring, security cameras - Gowning and cleaning protocols Gene Therapy Facility and Systems Experience - N+1 redundant utilities - Bioreactors - Process utility panels and distribution hook-ups - VHP (Vapor Hydrogen Peroxide) - WFI (Water for Injection) generation and distribution - BMS (Building Management System) controls & door interlocks - Environmental monitoring equipment (viable and nonviable particle counters) - Analytical equipment cell culture suites Common Gene Therapy Cleanroom Specifications Gene therapy cleanrooms are comprised of various ISO performance classifications ranging from ISO 5 (Class 100), ISO 6 (Class 1,000), ISO 7 (Class 10,000), ISO 8 (Class 100,000) backgrounds and CNC (Controlled Non-Classified) support zones. Critical supporting infrastructure such as N+1 redundancy across critical utilities, GMP Labs, cold boxes & environmental chambers, and process utilities such as WFI (water for injection), CO2, CDA, O2, WFI, RODI and N2 are common aspects of AdvanceTEC's integrated project delivery. ISO Classification - ISO 4 – (Class 10) – 300-540 ACPH - ISO 5 – (Class 100) – 240-480 ACPH - ISO 6 – (Class 1,000) – 150-240 ACPH - ISO 7 – (Class 10,000) – 60-90 ACPH - ISO 8 – (Class 100,000) – 5-48 ACPH European Standard - Grade A - Grade B - Grade C - Grade D - Controlled Non-Classified (CNC) Important Gene Therapy Regulatory Considerations There are various regulatory agencies to be considered for new gene therapy cleanroom facilities depending on the technology platform, facility type, scale and end market. - Good Manufacturing Practices (GMP) - US Food and Drug Administration (FDA) - National Institute of Health (NIH) - Office for Human Research Protections (OHRP) - Center for Biologics Evaluation and Research (CBER) - Regulations under Code of Federal Regulations (CFR) - European Union (EU Directive)
Vaccine Cleanrooms
Clinical Stage and High-Volume Production Vaccine Cleanrooms. Until recently, vaccines were something we focused on for our toddlers or if we were traveling to unique parts of the world. AdvanceTEC's cleanroom integration and design build platform is being leveraged for full scale up of multiple vaccine manufacturing facilities. Harnessing our 3D BIM to Build technology and integrated project delivery methodology, global technology leaders have embraced AdvanceTEC for their experience in vaccine cleanroom projects. Vaccines are said to be one of the trickiest things in science to create. Your cleanroom should be the easy part. Vaccine cleanrooms are purpose built facilities customized to the unique processes they enable. While every vaccine approach cleanroom is different, there are common cleanroom considerations that span the applications and technology platforms: Vaccine Cleanroom Design Considerations - MAL (Material Airlocks) / PAL (Personnel Airlocks) - Door interlocking and personnel flow patterns - Pressure cascades - Process equipment configuration and access - HVAC configurations and air flow segregation - Down flow booths or LAF (laminar air flow) modules - Low wall returns - Process distribution - Environmental monitoring - ISO classification, temperature & humidity - Viewing, monitoring, security cameras - Gowning and cleaning protocols Vaccine Facility and Systems Experience - N+1 redundant utilities - Bioreactors - Process utility panels & distribution hook-ups - WFI (Water for Injection) generation and distribution - VHP (Vapor Hydrogen Peroxide) - BMS (Building Management System) controls and door interlocks - Environmental monitoring equipment (viable and nonviable particle counters) - Analytical equipment Vaccine cleanrooms are comprised of various ISO performance classifications ranging from ISO 4 (Class 10) zones, to ISO 5 (Class 100), ISO 6 (Class 1,000), ISO 7 (Class 10,000), ISO 8 (Class 100,000) backgrounds and CNC (Controlled Non-Classified) support zones. Critical supporting infrastructure such as N+1 redundancy across critical utilities, in-line analytical testing labs, environmental chambers, and process utilities common aspects of AdvanceTEC's integrated project delivery. Specifications for vaccine cleanrooms vary based on process requirements. Provided below are typical specifications: ISO Classification - ISO 4 – (Class 10) – 300-540 ACPH - ISO 5 – (Class 100) – 240-480 ACPH - ISO 6 – (Class 1,000) – 150-240 ACPH - ISO 7 – (Class 10,000) – 60-90 ACPH - ISO 8 – (Class 100,000) – 5-48 ACPH European Standard - Grade A - Grade B - Grade C - Grade D - Controlled Non-Classified (CNC) There are various regulatory agencies to be considered for new vaccine cleanroom facilities depending on the technology platform and end market. - Good Manufacturing Practices (GMP) - US Food and Drug Administration (FDA) - World Health Organization (WHO) - National Institute of Health (NIH) - Office for Human Research Protections (OHRP) - Center for Biologics Evaluation and Research (CBER) - Regulations under Code of Federal Regulations (CFR) - European Medical Agency (EMA)
ISO 8 / Class 100,000 Cleanrooms and CNC (Controlled Non-Classified) Clean Spaces
ISO 8 or Class 100,000 Cleanrooms and CNC (Controlled Non-Classified) clean spaces common classifications of cleanrooms across a variety of industries and application types. ISO 8 Cleanrooms are utilized in biotechnology, pharmaceutical, electronic assembly, and various cleantech manufacturing applications such as ion lithium battery, solar, surgical kit assembly, packaging, nutraceuticals, and certain packages foods. Common ISO 8 Cleanroom Design Specifications and Considerations Filtration & Particle Control - Focused measurement of particle sizes greater than 0.5µ and less than 5.0µ - High Efficiency Penetration Air (HEPA) Filtration efficiency: 99.99% at 0.3 microns - Final filtration is performed at the air entry point of the cleanroom and is commonly performed by terminal HEPA modules or HEPA FFU (fan filter modules) depending on the application. - 3,520,000 PPC (particles per cubic meter) at 0.5µ - Environmental parameters such as temperature, humidity, lighting levels, noise criteria, static control, and outgassing are often driven by the requirements of the specific process being performed in the cleanroom. Airflow & Air Change Rates per Hour (ACPH) - Non-unidirectional airflow or mixed air flow patterns typically used. Airflow is most commonly a vertical flow from the ceiling to the floor, returning for conditioning and filtration through low wall returns. Certain applications or zones can make use of an up-flow air flow pattern, although this practice is less common. - Filtration Ceiling coverage is 5-15%, with a randomized array with filtration located over the highest control areas. - Non-unidirectional airflow or mixed air flow pattern typically used. Architectural Finishes - Wall systems: modular purpose-built wall systems depending on the application of the cleanroom. Biotech applications require non-shedding systems, with monolithic seams and coving to remove 90° angles, allowing wet washed down or VHP fogging to achieve sterile requirements. Nanotechnology and other non-sterile cleanroom types utilize non-shedding systems and are regularly dry wiped or vacuumed. - Ceiling systems: purpose-built ceiling systems are utilized for ISO 8 conditions depending on the application of the cleanroom. Biotech and pharmaceutical applications may use walkable or panelized ceiling systems to promote monolithic washable surfaces, and access to maintain lights and filter media from the top side of the ceiling without breaching the certified and validated space, or gasketed grid systems with lay-in lights and filters. Nanotechnology and other non-sterile applications commonly utilize gasketed grid systems with non-shedding blank ceiling tiles where devices such as filtration or lights are not populated - Flooring systems most commonly a resinous floor system, or heat sealed vinyl flooring system, with specific attributes depending on the application (i.e. chemical resistance, coving, static control, rolling weight loading / impact resistance, non-slip). - Miscellaneous architectural features to include types of doors, viewing windows, glass walls, pass-thrus, sprinkler heads / fire suppression, Wi-Fi / network access, security cameras, and access control devices. - Air returns: low wall returns or ceiling returns Recommended Gowning & Housekeeping - Recommended gowning requirements: head cover, goggles, beard cover, lab coat, foot coverings or booties, and gloves suitable to the task (i.e. vinyl, latex, nitrile). - Gowning room: separate (typically a lesser pressure and less stringent airlock) prior to entering the ISO 8 Cleanroom or CNC area. - No particle generation materials are allowed past material or personnel airlocks such as carboard, pallets, paper, dry erase boards, etc. ISO 8 Testing Required (ISO 14644-2) - Particle Count Test: maximum time interval 12 months, test procedure ISO 14644-1 Annex A - Air Pressure Cascade:maximum time interval 12 months, test procedure ISO 14644-1 Annex B5 - Airflow:maximum time interval 12 months, test procedure ISO 14644-1 Annex B4
ISO 7 (Class 10,000) Cleanroom Design and Construction
ISO 7 or Class 10,000 Cleanrooms are the broadest classification usage of cleanrooms across a variety of industries and application types. ISO 7 Cleanrooms are utilized in biotechnology, pharmaceutical, nanotechnology, compounding, and various cleantech manufacturing applications such as ion lithium battery, solar, medical device, film/packaging, nutraceuticals, and certain packages foods. Filtration & Particle Control - Focused measurement of particle sizes greater than 0.5µ and less than 5.0µ. - High Efficiency Penetration Air (HEPA) Filtration efficiency: 99.99% at 0.3 microns final filtration is performed at the air entry point of the cleanroom, and is commonly performed by terminal HEPA modules or HEPA FFU (fan filter modules) depending on the application. - 352,000 PPC (particles per cubic meter) at 0.5µ. - Environmental parameters such as temperature, humidity, lighting levels, noise criteria, static control, and outgassing are often driven by the requirements of the specific process being performed in the cleanroom. Airflow & Air Change Rates per Hour (ACPH) - Non-unidirectional airflow or mixed air flow patterns typically used. Airflow is most commonly a vertical flow from the ceiling to the floor, returning for conditioning and filtration through low wall returns. - Typical air changes: 60-90 air changes per hour - Filtration Ceiling coverage is 15-20%, with a randomized array with filtration located over the highest control areas. Architectural Finishes - Low wall air returns. - Wall systems: modular purpose-built wall systems depending on the application of the cleanroom. Biotech applications require non-shedding systems, with monolithic seams and coving to remove 90° angles, allowing wet washed down or VHP fogging to achieve sterile requirements. Nanotechnology and other non-sterile cleanroom types utilize non-shedding systems and are regularly dry wiped or vacuumed. - Ceiling systems: purpose-built ceiling systems are utilized for ISO 7 conditions depending on the application of the cleanroom. Biotech and pharmaceutical applications require walkable or panelized ceiling systems to promote monolithic washable surfaces, and access to maintain lights and filter media from the top side of the ceiling without breaching the certified and validated space. Nanotechnology and other non-sterile applications commonly utilize gasketed grid systems with non-shedding blank ceiling tiles where devices such as filtration or lights are not populated. - Flooring systems most commonly a resinous floor system, or heat sealed vinyl flooring system, with specific attributes depending on the application (i.e. chemical resistance, coving, static control, rolling weight loading / impact resistance, non-slip). - Miscellaneous architectural features to include types of doors, viewing windows, glass walls, pass-thrus, sprinkler heads / fire suppression, Wi-Fi / network access, security cameras, and access control devices. Recommended Gowning & Housekeeping - Recommended gowning requirements: head cover, goggles, beard cover,lab coat, foot coverings or booties, and gloves suitable to the task (i.e. vinyl, latex, nitrile) - Gowning room: separate (typically a lesser pressure, and one classification less stringent; i.e. ISO 8 airlock) prior to entering the ISO 7 Cleanroom - No particle generation materials are allowed past material or personnel airlocks such as carboard, pallets, paper, dry erase boards, etc. ISO 7 Testing Required (ISO 14644-2) - Particle Count Test: maximum time interval 12 months, test procedure ISO 14644-1 Annex A - Air Pressure Cascade: maximum time interval 12 months, test procedure ISO 14644-1 Annex B5 - Airflow: maximum time interval 12 months, test procedure ISO 14644-1 Annex B4 - While the above criteria can be tested and certified on a 12 months interval basis, it is recommended to be done on an every 6 months schedule.
ISO 6 Cleanroom Design and Build
ISO 6 or Class 1,000 Cleanrooms are a high usage classification of cleanrooms across a variety of industries and application types. ISO 6 Cleanrooms are utilized in biotechnology, pharmaceutical, nanotechnology, and various cleantech manufacturing applications such as ion lithium battery, solar, medical device, film / packaging, and fine chemical. Common ISO 6 Cleanroom Design Specifications and Considerations Filtration & Particle Control - Focused measurement of particle sizes greater than 0.5µ and less than 5.0µ - High Efficiency Penetration Air (HEPA) Filtration efficiency: 99.99% at 0.3 microns - Final filtration is performed at the air entry point of the cleanroom, and is commonly performed by terminal HEPA modules or HEPA FFU (fan filter modules) depending on the application. - 35,200 PPC (particles per cubic meter) at 0.5µ - Environmental parameters such as temperature, humidity, lighting levels, noise criteria, static control, and outgassing are often driven by the requirements of the specific process being performed in the cleanroom. Airflow & Air Change Rates per Hour (ACPH) - Unidirectional airflow or mixed air flow patterns typically used. Airflow is most commonly a vertical flow from the ceiling to the floor, returning for conditioning and filtration through low wall returns. - Filtration Ceiling coverage is 25-40%, with a randomized array with filtration located over the highest control areas. - Unidirectional airflow is utilized due to the more stringent requirements of ISO 6 cleanrooms. Architectural Finishes - Wall systems: modular purpose-built wall systems depending on the application of the cleanroom. Biotech applications require non-shedding systems, with monolithic seams and coving to remove 90° angles, allowing wet washed down or VHP fogging to achieve sterile requirements. Nanotechnology and other non-sterile cleanroom types utilize non-shedding systems and are regularly dry wiped or vacuumed. - Ceiling systems: purpose-built ceiling systems are utilized for ISO 6 conditions depending on the application of the cleanroom. Biotech and pharmaceutical applications require walkable or panelized ceiling systems to promote monolithic washable surfaces, and access to maintain lights and filter media from the top side of the ceiling without breaching the certified and validated space. Nanotechnology and other non-sterile applications commonly utilize gasketed grid systems with non-shedding blank ceiling tiles where devices such as filtration or lights are not populated. - Flooring systems most commonly a resinous floor system, or heat sealed vinyl flooring system, with specific attributes depending on the application (i.e. chemical resistance, coving, static control, rolling weight loading / impact resistance, non-slip). - Miscellaneous architectural features to include types of doors, viewing windows, glass walls, pass-thrus, sprinkler heads / fire suppression, Wi-Fi / network access, security cameras, and access control devices. - Air Returns: Low wall return - Wall system: modular purpose-built wall system (Biotech sterile, Nanotech non-shedding) - Ceiling systems: purpose-built ceiling system (Biotech walkable ceiling, Nanotech gasket grid FFU) Recommended Gowning & Housekeeping - Recommended gowning requirements: head cover, goggles, beard cover,lab coat, foot coverings or booties, and gloves suitable to the task (i.e. vinyl, latex, nitrile) - Gowning room: separate (typically a lesser pressure, and one classification less stringent; i.e. ISO 7 airlock) prior to entering the ISO 6 Cleanroom - No particle generation materials are allowed past material or personnel airlocks such as carboard, pallets, paper, dry erase boards, etc. ISO 6 Testing Required (ISO 14644-2) - Particle Count Test: maximum time interval 12 months, test procedure ISO 14644-1 Annex A - Air Pressure Cascade: maximum time interval 12 months, test procedure ISO 14644-1 Annex B5 - Airflow: maximum time interval 12 months, test procedure ISO 14644-1 Annex B4 - While the above criteria can be tested and certified on a 12 months interval basis, it is recommended to be done on an every 6 months schedule.
ISO 4 Class 10 Cleanroom Design and Build
ISO 4 or Class 10 cleanrooms are an ultra-clean stringently controlled cleanrooms utilized primarily for nanotechnology, semiconductor, and control zones within biotechnology and pharmaceutical applications for filling lines or other critical points. Common ISO 4 Cleanroom Design Specifications and Considerations Filtration & Particle Control - Focused measurement of particle sizes greater than 0.5µ and less than 5.0µ - Ultra-Low Particulate Air (ULPA) Filtration efficiency: 99.9995% at 0.12 microns. Final filtration is performed at the air entry point of the cleanroom, and is commonly performed by terminal HEPA modules, HEPA FFU (fan filter modules), or Plenum modules depending on the application. - 352 PPC (particles per cubic meter) at 0.5µ - Environmental parameters such as temperature, humidity, lighting levels, noise criteria, vibration, static control, and outgassing are often driven by the requirements of the specific process being performed in the cleanroom. - Uses higher air velocities, air changes, and high-efficiency particulate air / ultralow particulate (ULPA) filter coverage on ceilings or on walls - Max Particles: 10 per cubic foot of air at 0.12 microns Airflow & Air Change Rates per Hour (ACPH) - Laminar unidirectional airflow or mixed air flow patterns are required for ISO 4 cleanrooms. Airflow is only a vertical flow from the ceiling to the floor, returning for conditioning and filtration through low wall returns, or more commonly raised access flooring (RAF) perforated tiles. - Laminar Air Flow-Unidirectional airflow pattern is required - Typical air changes: 300-540 air changes per hour - Ceiling coverage: 50-90% Architectural Finishes - Wall systems: modular purpose-built wall systems depending on the application of the cleanroom. Biotech applications require non-shedding systems, with monolithic seams and coving to remove 90° angles, allowing wet washed down or VHP fogging to achieve sterile requirements. Nanotechnology and other non-sterile cleanroom types utilize non-shedding systems and are regularly dry wiped or vacuumed. - Ceiling systems: purpose-built ceiling systems are utilized for ISO 4 conditions depending on the application of the cleanroom. Biotech and pharmaceutical applications often require plenum module ceiling system to achieve both proper filter coverage and lighting levels. Nanotechnology and other non-sterile applications utilize plenum modules, or in smaller room spans gasketed grid or flush grid systems within integral lighting. - Flooring systems for ISO 4 are raised access flooring with perforated tiles for nanotechnology applications. Biotechnology and pharmaceutical applications utilize resinous flooring systems, but usually within enclosures (i.e. RABs, Downflow booths). Each system can provide attributes depending on the application (i.e. chemical resistance, coving, static control, rolling weight loading / impact resistance, non-slip). - Miscellaneous architectural features to include types of doors, viewing windows, glass walls, pass-thrus, sprinkler heads / fire suppression, Wi-Fi / network access, security cameras, and access control devices. - Air Returns: Low wall return or Raised Floor Recommended Gowning & Housekeeping - Required gowning requirements: full bunny suit with head cover, beard cover, foot coverings, often with face shields and personnel exhalation filtration, and gloves suitable to the task (i.e. vinyl, latex, nitrile) - Gowning room: separate (typically a lesser pressure and one classification less stringent; i.e. ISO 5 airlock) prior to entering the ISO 4 Cleanroom or zone. - No particle generation materials are allowed past material or personnel airlocks such as carboard, pallets, paper, dry erase boards, etc. ISO 4 Testing Required (ISO 14644-2) - Particle Count Test: maximum time interval 6 months, test procedure ISO 14644-1 Annex A - Air Pressure Cascade: maximum time interval 6 months, test procedure ISO 14644-1 Annex B5 - Airflow: maximum time interval 6 months, test procedure ISO 14644-1 Annex B4
503B Compounding Pharmacy Cleanrooms
The innovation of personalized medicine, compounded to an individual’s health needs has been a revolution in medicine over the last decade. AdvanceTEC is focused on serving leading clients in the 503B Compounding segment who are held to stringent cGMP (Current Good Manufacturing Practices) and FDA inspections and compliance.Clinical or commercial scale compounders in the 503B segment benefit from AdvanceTEC’s cleanroom integration and total performance delivery. AdvanceTEC’s unique Open Market, Zero Compromises offering to 503B is a customer centric approach that provides certainty of cost, schedule and total performance for you. Common 503B Compounding Cleanroom Considerations While there are variations in terms of scale, layout, and total output needs from one 503B cleanroom to another, there are also common cleanroom considerations we see serving this market. 503B Compounding Cleanroom Design Considerations - Airflow arrangements - Pressurization cascades - HVAC configurations - Low wall air returns - Temperature, humidity and particle control - Gowning and cleaning protocols Common 503B Compounding Cleanroom Specifications Specification for 503B pharmaceutical compounding cleanrooms vary based on process requirements. Typical 503B compounding facilities perform their requirements in and ISO Class 5 (Class 100) zone or control area, ISO 7 (Class 10,000) cleanroom background, and a gown room / anteroom of either ISO 7 or ISO 8. ISO Classification - ISO 4 – (Class 10) – 300-540 ACPH - ISO 5 – (Class 100) – 240-480 ACPH - ISO 6 – (Class 1,000) – 150-240 ACPH - ISO 7 – (Class 10,000) – 60-90 ACPH - ISO 8 – (Class 100,000) – 5-48 ACPH European Standard - Grade A - Grade B - Grade C - Grade D - Controlled Non-Classified (CNC) Important 503B Compounding Regulatory Considerations In the US, 503B compounding facilities are regulated by the US Food and Drug Administration (FDA) with oversite through its related organizations, including: - Good Manufacturing Practices (GMP) - US Food and Drug Administration (FDA) - The Drug Quality and Security Act (DQSA) - United States Pharmacopeia (USP) - The Drug Enforcement Administration (DEA) - 21 CFR Part 210: Current Good Manufacturing Practice in Manufacturing Processing, Packing, or Holding of Drugs - 21 CFR Part 211: Current Good Manufacturing Practice for Finished Pharmaceutical
Process Integration
Your process is why you need a cleanroom in the first place. Unfortunately to some, a cleanroom is just a “shiny white box” that blows filtered air. But unless the process requirements have been integrated, it’s just a shiny white waste of money. While others focus on selling you walls, ceilings and doors, we focus on total performance of the cleanroom and your critical processes inside. If you’re in Biotech, it’s process system integration. If you’re in Nanotech its process tool install. If you’re at AdvanceTEC, it’s what matters: your process, your process systems, your process tool-set, and your process utilities that serve them. It’s the professional integration of these critical systems that makes your cleanroom a successful. At AdvanceTEC we have been integrating and installing complex process systems since our founding. Our 3D BIM modeling internal library enables speed and accuracy for your process integration. AdvanceTEC has proven experience designing and installing a wide range of process tools and systems, including: Biotech Integration Examples - Process systems & personnel, material and waste flows - Process skids and utility connections - Process utility panels - Process pass-thrus - Clean steam - WFI (Water for Injection) systems and distributions - VHP (Vapor Hydrogen Peroxide) - HVAC duct racks - Restricted Access Barriers (RAB) - Autoclaves and sterilization - Fill finish lines and packaging integration Nanotech Process Tool Installation Examples - Process tool-set layout and utility run outs - High-purity gas cabinets & distribution - Ultra-Pure Water (UPW) - TGMS (Toxic Gas Monitoring) systems - UPW (Ultra-Pure Water) skids and distribution - MEP pipe racks - AWN (Acid Waste Neutralization) - Chemical dispense systems - Scrubbed exhaust and waste abatement - Life safety and controls - Gas sticks & pods Your process is our focus. We integrate your process into the cleanroom. AdvanceTEC’s 3D BIM library of process systems allow us to quickly layout your process and the cleanroom serving it. We leverage our in-house experts in Biotech, Nanotech and Cleantech to understand your process and create the best approach to achieve your cost, schedule and operational objectives.
Biosafety Level 2 (BSL-2) Cleanroom and Laboratory
Level of protection appropriate for handling moderate-risk agents that cause human disease of varying severity by ingestion or through percutaneous or mucous membrane exposure. Biosafety Level 2: Overview - Biosafety Level 2 standards, protocols, and engineering, design, and construction techniques build upon BSL-1. - BSL-2 cleanrooms and laboratories commonly handle applications such as equine encephalitis viruses and HIV, as well as Staphylococcus aureus (staph infections). - BSL-2 cleanrooms and laboratories are separated from the general traffic patterns in the building. - Special containment equipment or facility design is required - Personnel must have specific training in the procedures conducted in the BSL-2 cleanroom or laboratory. Personnel are trained to handle pathogenic agents and are supervised by those with advanced training. - Biosafety cabinets or other physical containment for all procedures that can generate infectious aerosols or splashes. - Autoclave or other method of decontamination for proper disposal of materials or sterilization for re-use. - Eyewash station or eyewash safety shower - Interlocking doors, and commonly with badge-controlled facility access - Extra care is taken to control routes of exposure, including advanced techniques for handling contaminated sharps - Immunizations are provided to lab personnel when appropriate - Additional PPE, such as face shields may be necessary - A lab-specific biosafety manual that outlines the necessary controls and practices for the work performed in that lab is established and well known by the trained team working in the area. Common BSL-2 Considerations for Architectural Finishes - Materials of construction and finishes: non-porous, smooth, cleanable, withstand cleaning / sanitization agents, not supporting microbial growth - Walls: modular construction - Ceilings: modular panel system - Doors: single & double leaf sliding seamless door frame - Floors: troweled self-leveling epoxy flooring - Exterior glazing: not recommended, corridor separating exterior from BSL spaces preferred - Interior glazing: single or double glaze impact resistant and sealed - Air Changes Per Hour (ACPH): 15 minimum
Biotech and Pharmaceutical Cleanroom Design & Build
AdvanceTEC is the industry leading design & build cleanroom and process integration provider where experts with decades of segment experience apply the latest digital tools and technologies to deliver outstanding outcomes for customers. AdvanceTEC has a proven track record of addressing project schedule, mechanical systems and modular system integration requirements for leading edge Biotech and Pharmaceutical cleanrooms. From venture backed start-ups to publicly traded global biotech leaders, AdvanceTEC can help you reach your objectives, whether it’s a new build, upgrades, repurpose, expansions or renovations. Segment Expertise In-House: AdvanceTEC brings the in-house expertise to ensure the success of your project: FDA guidelines, EU guidelines, BSL requirements, bag-in bag-out filtration, glass walls, filling lines, downflow booths, cold boxes, quarantine areas, WFI water, modular off-site and on-site integration, glass walls, walkable ceilings, single use strategies. Clinical Trails, GMP Labs, CRO, CMO, High Volume Production. Cleanroom Features - Modular Off-Site Fabrication / On-Site Integration - cGMP cleanroom architectural finishes - Walkable ceiling systems - Glass walls - LED Walk-on light systems - Process utility panels and skid integration - Panelized ceilings - Plenum module and flush grid systems - Resinous flooring systems - Door finishes, operators and hardware - WFI water systems - MALs, PALs and Air locks - Restricted access barrier (RAB) - Down flow booths - Bag-in / bag-out filtration. Facility Types - Gene therapy - Vaccine research and production - CAR-T Cancer - Clinical trial - BSL-1, BSL-2, BSL-3 - Single-use “Disposable” processes - Fill finish - Cell culture suites - R&D applications labs - Modular laboratories - Fill finish lines - Clean storage - Modular support rooms. Cleanliness Classifications ISO Standard 14446 - ISO 4 - ISO 5 - ISO 6 - ISO 7 - ISO 8. European Standard - Grade A - Grade B - Grade C - Grade D - Controlled Non-Classified (CNC). Biosafety Levels - BSL 1 - BSL 2 - BSL 3. Federal Standard 209e - Class 10 - Class 100 - Class 1,000 - Class 10,000 - Class 100,000.
Cleanrooms for Renewable Energy
When most people think of renewable energy they think of windmills, solar panels and EV (electrified vehicles). At AdvanceTEC we think of cleanrooms for hyper-pure polysilicon, cleanrooms for ion lithium battery fabrication, and cleanrooms for materials science searching for the next energy efficient nano-materials. We think of harnessing the power of the sun, storing it efficiently, and transporting it to its point of use at the speed of light. AdvanceTEC’s Cleanroom Integration expertise has been successfully leveraged by clients in the renewable energy and energy distribution space. Renewable Energy Cleanroom Considerations AdvanceTEC’s Cleanroom Integration has led some of the most advanced efforts for renewable energy industry. While each client and project has been different, there are key attributes that are common across the market. General Cleanroom Design Considerations - Trace metals cleanrooms - Analytical trace metals labs - Temperature, humidity, static control - Ultra-low humidity clean dry rooms - Airflow arrangements - HVAC configurations - BMS (Building Management Systems) controls - Ultra-high purity water (ASTM E1, ASTM E1.1, ASTM E1.2) - Ultra-high purity gases and orbital welded stainless - Vibration abatement - Scrubbed exhaust - Waste abatement - Gowning and cleaning protocols Renewable Energy Cleanroom Specifications Specifications vary based on the technology pursuit and the required process requirements. Typical renewable energy processes can be performed in a mix of ISO 5 (Class 100) or ISO 6 (Class 1,000) environment to an ISO 7 (Class 10,000) or ISO 8 (Class 100,000) environment base on project requirement. Provided below are typical specifications: ISO Classification - ISO 4 – (Class 10) – 300-540 ACH - ISO 5 – (Class 100) – 240-480 ACH - ISO 6 – (Class 1,000) – 150-240 ACH - ISO 7 – (Class 10,000) – 60-90 ACH - ISO 8 – (Class 100,000) – 5-48 ACH
Turn-key Design Build Cleanrooms for Nanotechnology and Semiconductor Fabs
AdvanceTEC is the market leader of turn-key design build cleanrooms for nanotechnology and semiconductor device fabrication “fabs.” Our advanced 3D BIM / VDC modeling, high purity process integration, and fast-track clean build methodologies have been leveraged by leading tech companies ranging from venture capital backed start-ups to global technology leaders. Our skillset serves customers well across projects ranging from pilot lines, high volume fabs, or foundry applications—regardless of wafer size or if your process is CMOS, GaAs, GaN, or other advanced composite materials. We’ve delivered Class 10 / ISO 4 photo bays, Class 100 / ISO 5 deposition areas, Class 1,000 / ISO 6 metrology & metals cleanroom areas, and more to our customers. AdvanceTEC has segment expertise in-house to handle your most pressing technology and project challenges. Cleanroom Fab Design Considerations - Bay & chase cleanroom design configuration - Ballroom and RAF (raised access floor) cleanroom design and configuration - FFU (Fan Filter Unit) air delivery and plenum ceiling - Plenum modules 100% filter coverage with flush grid and integrated lighting and sprinkler - Mini-environments - Tool-set layout and process utility generation and distribution - Trace metals or metals free cleanrooms - EMI shielded rooms and service utilities - Vibration free zones - Static control - Light and sound abatement - Radiant cooled areas with ultra-low air velocities Fabrication Cleanroom Systems Experience - Building Automation Systems (BAS) / Building Management Systems (BMS) - High-purity gas cabinets, distribution panels and ventilated enclosures, and gas bunkers - High purity piping and tubing systems - Ultra-Pure Water (UPW) skids and distribution loops - Toxic Gas Monitoring Systems (TGMS) - Scrubbed exhaust systems - Chemical dispense systems - Environmental and particle monitoring systems
Process Tool Installation & Fit-Up (Nanotech)
Designing from the Inside Out Your process, your process tool-set, and your process utilities that serve them are why you are building a cleanroom in the first place.… Not the other way around. AdvanceTEC is the best in the business at engineering, designing, 3D BIM modeling, coordinating, constructing and commissioning mission critical process utilities distribution and process tool fit-up for the tool-sets they serve. It’s the heat load, exhaust load, process utilities, and process tool-set layout that drives the engineering and design of your cleanroom – which is why we design from the inside out! Process Tool Installation & Fit-Up Driven by technology roadmaps, tool-set changes, and production ramps, ultra-clean process utilities and tool-set installs are more critical now than ever before. Our decade deep 3D BIM library of process integration projects enables us to model, integrate, and construct your process requirements at a very rapid pace. Verification of best practices, past successes, and final objectives are implemented by our in-house team of engineers, designers, and 3D BIM modeling experts, with constructability and integration reviews with field teams. Below is a representative list of nanotech process integration that AdvanceTEC has segment expertise to perform for you: Process Utilities - TGMS (Toxic Gas Monitoring Systems) - Code and life safety compliance - Ultra-pure water systems with PVDF and Teflon distributions - Coated stainless steel exhaust systems - AWN (Acid Waste Neutralization) and disposal - Chemical dispense systems - In-line particle counts - Orbital welded stainless for spec gases - EMI shielded rooms - Vibration abatement and pedestals Equipment Installation - TEM / SEM Rooms - E-Beam lithography - Deposition tool sets - Ion implant - Metrology - Automated wet process stations - Fume hoods - Packaging and testing
Turn-Key Design Build Cleanrooms
Single Point Responsibility, Maximum Focus, Maximum Value, Minimum Risk Want to avoid excuses? Want to avoid delays? Want to avoid finger pointing? You want AdvanceTEC Turn-Key Design Build for your next cleanroom and process integration project. Our approach to turn-key design build is different. We take time upfront to understand your technology, your process requirements and your objectives. Then our team of experts leverages automation tools, in-house 3D BIM / VDC modeling, and decades of experience and applies it to your project. By providing initial layouts, budgets, and schedules upfront in the process, we focus on the details to make certain your objectives are achieved. With AdvanceTEC turn-key design build, you have single point responsibility and accountability for quality, cost, schedule and total performance. - Avoid delays to your project from multiple entities not communicating or coordinating - Confirm your budget, know your options, and have confidence in you project schedule at the concept stage - Upfront sizing of HVAC, mechanical, electrical, process & plumbing, and waste abatement requirements to avoid costly surprises - Integrate process systems into the cleanroom, and integrate your cleanroom into your building - Confirm life safety plans and building code compliance - Plan for future expansions, upgrades, and technologies - Conduct approvals with EHS (environmental, health and safety), building code officials, insurance carriers, and regulatory bodies at the start to avoid delays From concept through commissioning, ISO certification and owner training – AdvanceTEC engineers, 3D BIM models, estimates and creates ISO certified cleanrooms and validated process systems to enable your innovations and achieve your business plans.
Integrated Project Delivery (IPD)
Collaboration, Technology and Teamwork IPD (Integrated Project Delivery), LEAN Construction, TVD, TAKT planning, “big room,” pull planning, last planner, touch plan – call it what you like. At AdvanceTEC we call it Teamwork! Regardless of your terminology, acronym or favorite approach, it’s all about adding value, increased collaboration and reducing costs and schedules. Put simply: communicate, collaborate, and INTEGRATE! AdvanceTEC teams with industry leading Construction Managers (CM), Engineering Procurement and Construction Management (EPCM), and sophisticated General Contractors (GC) to serve clients across Biotech, Nanotech and Cleantech cleanroom and process applications. Our depth of knowledge, segment expertise, and world-class 3D “BIM to Build” capabilities provide fluid integration into collaborative teams with shared initiatives. We serve as the mission critical cleanroom and process integration expert within these diverse IPD teams. - 3D BIM model creation, integration, coordination, clash detection & resolution - On-site digital building scanning, scan point cloud to BIM coordinates, BIM to building layout coordinates - Concept stage cost estimates, change management & control, bid-tabbed options, and schedule integration with team partners - Cleanroom and process layout with scope lines of demarcation - Phased funding, cash flow curves, innovative technical and commercial solutions Some people may “talk” about teamwork, but at AdvanceTEC we “walk the talk” about teamwork. Teamwork is central to who we are and what we do. We embrace IPD and LEAN construction approaches at AdvanceTEC; it’s all about how we communicate, collaborate, and INTEGRATE!
Prefabricated and Modular Cleanrooms
It’s a race against the clock to get your site selected, equipment ordered, facility commissioned, and your product to market. We understand with the rapid deployment of your facility comes pressure and uncertainty. The uncertainty of risks, the uncertainty of cost, and the uncertainty of schedule. That’s why AdvanceTEC’s prefabricated modular offsite cleanroom execution and JIT onsite integration is the solution for you. Our customers benefit from improved schedules, quality, site logistics, safety, and the overall performance of their project. We take high-tech construction integration to the next level all while reducing costs, onsite installation time, logistical congestion, and accidents by performing duties in an offsite fabrication facility. Prefabricated and modular cleanroom finishes have been embraced across the industry for years. From innovative biotech start-ups to global chip companies, everyone is seeking to reduce risks, increase safety, and achieve time to market for their investment. What’s evolved is the innovative approaches to modules, modularization, and decisions made around what must be performed onsite and what can be completed offsite. By streamlining AEC workflows all while utilizing Prefabrication, Preassemble, Modularization, and Offsite Fabrication(P.P.M.O.F.) strategy, we maintain our clients demanding schedules, sustain project costs, and ultimately hit their time to market requirements. Here’s just of few examples of what AdvanceTEC can do off-site: - Cleanroom modular finishes - MEP pipe racks - HVAC duct racks - Process Skid Plates - Gas sticks and racked pods - Zoned construction kits - Module (Pod) experience
Cleanroom Renovations & Retrofit
Retrofitting a cleanroom into an existing structure, making an existing production line “clean,” upgrading a current operation to meet new standards for quality, purity or performance? Maybe you’re looking to redeploy capital and leveraging an existing building that has already been depreciated? This approach has been taken by many technology leaders across a variety of industries, and AdvanceTEC has been there to help them refurbish, upgrade and retrofit the latest cleanroom and contamination control technology. AdvanceTEC leverages our experience and technology to enable your technology: - Understand your challenge, your technology, your process, and your definition of success - Study existing facility drawings and data to quantify available base utilities - Conduct a site survey using digital field scanning - Leverage data from digital field scans to 3D BIM Model / VDC - Identify process utilities and infrastructure needed to service your needs - Create a cleanroom facility and integrate your equipment and process to serve your needs - Sequence a project execution plan that minimizes downtime or disruption to current operations - Use modular off-site fabrication and on-site integration of systems and racks enhance speed and quality AdvanceTEC’s proven cleanroom retrofitting expertise ensures the right design, effective project execution, and the right performance to enable your technology. AdvanceTEC has been there to help them refurbish, upgrade and retrofit the latest cleanroom and contamination control technology.
Government Cleanrooms, Labs and Process
Government labs and advanced research centers serve a vital need for our country and future of scientific advancements. AdvanceTEC is the market leader in cleanroom and advanced labs serving leading government installations. We are proud of the important role we have played in serving government organizations for decades, and are committed to doing what it takes to execute successful projects for our government labs and advanced research centers. Government Research Expertise In-House AdvanceTEC brings the in-house expertise in Nanotechnology, Biotechnology, and Cleantech for cleanrooms, process equipment installation, process utility upgraded, retrofits, or installations to ensure the success of your government research center. Leverage our industry expertise and safety culture to provide your facility what it needs to remain on the leading edge of science. Cleanrooms, Labs, Renovations From trace metals labs to atomic force microscope quiet labs to cleanroom fabs, AdvanceTEC can help you reach your objective. We know the challenges – life safety, code compliance, quality, stability, ISO Classifications – and our expertise and resource team scales to fit your budget, your schedule and your needs.
University Cleanroom Design & Build
University cleanroom and process tool installation projects require a unique approach and thoughtful execution. AdvanceTEC is a leader in cleanroom and mission critical process utilities and system installation projects for university and college clients. We have been serving university customers for decades, and know how to operate safely on an active campuses and understand what it takes to deliver successful university cleanroom projects to your requirements and your budget. Whether it is a new integrated or multidisciplinary science building, or retrofitting a lab adjacent to operating facilities – we can help. University Expertise In-House AdvanceTEC brings the in-house expertise in Nanotech, Biotech and Cleantech for cleanrooms, process equipment installation, process utility upgraded, retrofits and installations to ensure the success of your project. Leverage our industry expertise and on campus safety culture to advance your program and energize your school.
Advanced Laboratory Considerations
While every laboratory has its own specific processes, requirements, and challenges below are common advanced laboratory considerations that AdvanceTEC is skilled at addressing; Advanced Laboratory Considerations - Personnel protection and life-safety - HVAC and exhaust systems energy management - Fume hoods - Downflow booths - ISO Classifications - HEPA, ULPA and AMC Filtration - Airflow modeling and patterning - UPW (Ultra-Pure Water) Systems - High-purity spec gas cabinets and distribution systems - O2 Oxygen sensors - Trace metals / metals free environments - Environmental stability and monitoring - Proper training, safety, and maintenance of technical staff - Pressure cascades and airflow patterning - BMS (Building Management Systems) controls and alarms - Utility distribution and access
Nutraceuticals Cleanrooms
Over the years, nutraceuticals have attracted considerable interest due to their nutritional, safety, and therapeutic effects. Often referred to as phytochemicals, or functional foods, they are natural, bioactive chemical compounds that have health-promoting, disease-preventing or medicinal properties. These products have been used to treat and prevent a variety of diseases that range from oxidative stress, Alzheimer’s, cardiovascular disease, cancer, diabetes and Parkinson’s. Every product has a different set of manufacturing challenges, based on ingredients, material sources and final form. Creating an isolated environment can help alleviate these risks helping you bring the best product to market. See how AdvanceTEC can bring our experience to bear on your next critical project.
Cannabis Cleanrooms
Cannabis is no longer a dirty word. In fact, in various medical and disease research communities the controlled use of THC medical marijuana is showing impressive results suppressing muscle spasticity, spams, bladder dysfunction, chronic pain, chemotherapy induced pain & nausea, and symptoms of Multiple Sclerosis. Applications ranging from chronic pain management, chemotherapy treatments, seizures from epilepsy are only just the beginning. Cannabis today is being grown in highly controlled grow rooms, where the process from seed to product is using GMP cleanroom manufacturing and process validation techniques once reserved for only pharmaceutical and biotechnology cleanroom users. AdvanceTEC’s experience in these areas can provide a significant advantage to your next project.
Nanotech Lab Design-Build
AdvanceTEC is highly skilled in providing fully integrated design-build labs for supporting the most advanced forms of research, development and in-line QA/QC support of production. Our 3D BIM / VDC modeling with virtual reality (VR) BIM tours is especially helpful for lab layout of personnel and process flow to identify features and paths of access and egress. AdvanceTEC’s HVAC engineering and design capabilities brings tremendous value in the forms of energy management, air flow patterning and effectively addressing both personnel and process protections. Our segment expertise includes: Clean labs; QA/QC labs; Metrology labs; Wet chemistry labs; Quiet labs; Trace metals labs; GMP labs
Medical Device Cleanrooms
Implantable medical devices – think hips, knees, pacemakers and so on – are mission critical products that require mission critical performance. Precision, reliability, cleanliness and sterile packaging prior to shipment are attributes required for today’s medical device cleanroom applications. AdvanceTEC’s Cleanroom Integration can be put to work for you to achieve your total performance requirements.
Tissue Bank Cleanrooms
Organ donorship continue to grow in population year after year. Applications for vital organ transplants like heart, kidney, liver; soft tissue donor and usage for retina, ligament and the like; and even the refinement of donated bone is in high demand and usage. AdvanceTEC’s experience and leadership in biotechnology and pharmaceutical cleanrooms can benefit your tissue bank cleanroom project.

Contract & Professional Service Providers · 201–500 employees · United States
8 listed under this category
MPW Base Active PIC
The MPW Base Active PIC consists of one silicon and two silicon nitride waveguides. Six implant levels are available for active component design, a Ge photodetector, two copper wiring levels, and an Al termination pad level. On the base active build, silicon waveguide propagation loss target is 1.95 dB/cm while the silicon nitride waveguide propagation loss target is 1.85 dB/cm. Lower loss waveguides are available with our other offerings. The Base Active PIC is supported by component libraries from Analog Photonics (APSUNY), Spark Photonics, the Research Foundation for SUNY (RFS) and Dream Photonics: - The APSUNY library is a comprehensive, high performance, black box library focused on operation in the O, C, and L bands. - The Spark Photonics library features waveguides, input couplers, MMIs, and more focused on operation from 700-1300nm. - The RFS library includes basic passive components such as input couplers, power taps, and splitters. - The Dream Photonics library supports many waveguide geometries and also includes couplers, splitters, thermal phase shifters, and optical attenuators and detectors. Customization Available - Adjust ridge depth - Adjust waveguide thicknesses - Adjust vertical spacing between waveguides - Trench to the waveguides with or without expose - Extra/custom implants - Extra wiring level While MPWs typically follow a standard process flow that designers cannot modify, AIM Photonics has developed a "bite size custom" offering where designers can make minor changes to the process flow for an additional fee. This is not a full custom run, and the modification must be something the fab team can execute without development work. The exact specifications and complexity of the design may affect which run it will ultimately ride on, and in most cases, this can vary between one and two months. Please contact us well in advance of the design due date to ensure the fab team understands your request and can properly quote the work. Run schedule: 2026 ACT 26-01A — Design Due Mar 2, 2026 — Expected Ship Aug 3, 2026 ACT 26-02P — Design Due Jun 1, 2026 — Expected Ship Nov 2, 2027 ACT 26-03A — Design Due Sep 1, 2026 — Expected Ship Feb 2, 2027 ACT 26-04A — Design Due Dec 1, 2026 — Expected Ship May 4, 2027 Pricing (per 20 qty chips): 8 mm2 — Member $35,750 — Non-Member $42,900 25 mm2 — Member $71,500 — Non-Member $85,800 50 mm2 — Member $143,000 — Non-Member $171,600 100 mm2 — Member $286,000 — Non-Member $343,200 Notes - Start dates for runs are subject to change. - Member prices shown are for customers who are Full Active Members and have executed an AIM Photonics Membership Agreement. - Customer receives 20 qty unpackaged chips of the size/technology ordered. - All chips are placed in a gel-pack and shipped to the customer as part of Standard MPW Offerings pricing. - For an additional charge, sub-dicing or post processing is available – please see information about Testing, Assembly and Packaging (TAP) Services. - All pricing shown subject to change
Active PICs - Multi-Project Wafer (MPW) Volume Pricing
Active PIC Offerings, priced by chip area and quantity. 8 mm2: 20 chips $35,750 member / $42,900 non-member (0% discount); 30 chips $48,263 / $57,915 (10%); 40 chips $57,200 / $68,640 (20%); 60 chips $75,075 / $90,090 (30%); 80 chips $85,800 / $102,960 (40%); 100 chips $89,375 / $107,250 (50%). 25 mm2: 20 chips $71,500 / $85,800 (0%); 30 chips $96,525 / $115,830 (10%); 40 chips $114,400 / $137,280 (20%); 60 chips $150,150 / $180,180 (30%); 80 chips $171,600 / $205,920 (40%); 100 chips $178,750 / $214,500 (50%). 50 mm2: 20 chips $143,000 / $171,600 (0%); 30 chips $193,050 / $231,660 (10%); 40 chips $228,800 / $274,560 (20%); 60 chips $300,300 / $360,360 (30%); 80 chips $343,200 / $411,840 (40%); 100 chips $357,500 / $429,000 (50%). 100 mm2: 20 chips $286,000 / $343,200 (0%); 30 chips $386,100 / $463,320 (10%); 40 chips $457,600 / $549,120 (20%); 60 chips $600,600 / $720,720 (30%); 80 chips $686,400 / $823,680 (40%); 100 chips $715,000 / $858,000 (50%). Notes: Member Prices shown are for customers who are Full Active Members and have executed an AIM Photonics Membership Agreement. All chips are placed in a gel-pack and shipped to the customer as part of Standard MPW Offerings pricing. For an additional charge, sub-dicing or post processing is available – please see information about Testing, Assembly and Packaging (TAP) Services. All pricing shown is subject to change. Chip quantity is dependent on yield and is not guaranteed. Quantities requested are on a first-come, first-served basis.
Base Passive PIC (Multi-Project Wafer)
The MPW Base Passive PIC consists of one silicon and two silicon nitride waveguides. A trench is available to remove most of cladding oxide over the first nitride waveguide. On the base passive PIC build build, silicon waveguide propagation loss target is 0.75 dB/cm while the silicon nitride waveguide propagation loss target is 0.5 dB/cm. Lower loss waveguides are available with our other offerings. The Base Passive PIC is supported by component libraries from Analog Photonics (APSUNY), Spark Photonics, the Research Foundation for SUNY (RFS) and Dream Photonics. Customization Available - Adjust ridge depth - Adjust waveguide thicknesses - Adjust vertical spacing between waveguides - Trench to the Si waveguide - Fully expose Si or SiN waveguide in the bottom of a trench While MPWs typically follow a standard process flow that designers cannot modify, AIM Photonics has developed a “bite-size” custom offering where designers can make minor changes to the process flow for an additional fee. This is not a full custom run, and the modification must be something the fab team can execute without development work. The exact specifications and complexity of the design may affect which run it will ultimately ride on, and in most cases, this can vary between one and two months. Please contact us well in advance of the design due date to ensure the fab team understands your request and can properly quote the work.
Electronic Interposer - Multi-Project Wafer (MPW) Volume Pricing
Electronic Interposer, priced by chip area and quantity. 156 mm2: 20 chips $90,000 member / $108,000 non-member (0% discount); 30 chips $121,500 / $145,800 (10%); 40 chips $144,000 / $172,800 (20%); 60 chips $189,000 / $226,800 (30%); 80 chips $216,000 / $259,200 (40%); 100 chips $225,000 / $270,000 (50%). Notes: Member Prices shown are for customers who are Full Active Members and have executed an AIM Photonics Membership Agreement. All chips are placed in a gel-pack and shipped to the customer as part of Standard MPW Offerings pricing. For an additional charge, sub-dicing or post processing is available – please see information about Testing, Assembly and Packaging (TAP) Services. All pricing shown is subject to change. Chip quantity is dependent on yield and is not guaranteed. Quantities requested are on a first-come, first-served basis.
Indium Phosphide (InP) Photonic Integrated Circuit Multi-Project Wafers (MPW)
Sandia National Laboratories offers InP multi-project wafer capability at its New Mexico site, complementing AIM Photonics’s silicon photonics capability. Sandia specializes in InP for U.S. entities that need export-control, collaborative development, and/or more platform flexibility. Sandia’s model is a design-assisted MPW. Sandia is not a pure-play foundry.
Passive MPW Runs
Notes - Start dates for runs are subject to change. - Gray boxes indicate a completed MPW run Year | Run ID | Design Due Date | Expected Ship Date 2026 | PAS 26-01P | Mar 2, 2026 | Jun 1, 2026 PAS 26-02P | Jun 1, 2026 | Sep 1, 2026 PAS 26-03P | Sep 1, 2026 | Dec 1, 2026 PAS 26-04P | Dec 1, 2026 | Mar 2, 2027 2027 | PAS 27-01P | Mar 1, 2027 | Jun 1, 2027
Multi Project Wafer/Assembly (MPWA)
Provision of full MPWA services including foundry broker and foundry operations for both Si and InP-based photonic devices and components. Features: Availability of in-house 300mm Si and InP fabrication facilities; III-V laser integration; Interposer 2.5D/3D integration; and integrated inline and optical test.
AIM Photonics Wafer Fabrication (MPW)
Working with AIM Photonics to purchase wafer fabrication or test, assembly and packaging a services involves the disclosure of confidential information, therefore the first step is to enter into an agreement which covers the terms and conditions surrounding this disclosure.

Contract & Professional Service Providers · 11–50 employees · Canada
2 listed under this category
NanoSOI Silicon MPW Runs
Design rules for each layer available in the NanoSOI Silicon MPW runs. Layer 1: Silicon full etch. Minimum feature size 60 nm lines. Minimum feature spacing 70 nm lines. Design area 9 mm x 9 mm. Feature sizes specified where duty cycle of surrounding region is ≤ 50%. Layer 1: Silicon full etch IF both air cladding and deep trench are required. Minimum feature size 100 nm lines. Minimum feature spacing 100 nm lines. Design area 9 mm x 9 mm. If air cladding and deep trench are required, the silicon feature size increases to improve yield. Layer 5: Direct metallization. Minimum feature size 5 μm. Minimum feature spacing 10 μm. Design area: Standard layout is 9 x 9 mm. Deep trench layout is 8.745 x 8.745 mm. Requires prior approval to use. Please inquire with Support two weeks before MPW deadline. Layer 6: Through-cladding windows. Design area: Standard layout is 9 x 9 mm. Deep trench layout is 8.78 x 8.78 mm. Requires prior approval to use. Please inquire with Support two weeks before MPW deadline. Layer 11: Tri-layer metal: TiW alloy. Minimum feature size 3 μm. Minimum feature spacing 3 μm. Design area: Standard layout is 9 mm x 9 mm. Deep trench layout is 8.745 mm x 8.745 mm. Layer 12: Tri-layer metal: TiW/Au Bilayer. Minimum feature size 5 μm. Minimum feature spacing 8 μm. Design area: Standard layout is 9 mm x 9 mm. Deep trench layout is 8.745 mm x 8.745 mm. Layer 13: Tri-layer metal: Bond pad open. Minimum feature size 10 μm. Minimum feature spacing 10 μm. Design area: Standard layout is 9 mm x 9 mm. Deep trench layout is 8.745 mm x 8.745 mm. Must be placed over Layer 12 and smaller than Layer 12 by 5 μm. Layer 189: Custom dicing. Minimum feature size 100 μm. Minimum feature spacing 3 mm. Design area 9 mm x 9 mm. 50 μm spacing to devices. Layer 200: SEM imaging. Minimum feature size 500 nm wide. Design area 9 mm x 9 mm. Only rectangular boxes with aspect ratio 4:3 (width to height). Layer 201: Deep trench. Minimum feature size 260 μm. Minimum feature spacing 3 mm. Design area 8.78 mm x 8.78 mm. 35 μm spacing to metal. Only extend Layer 1 edge couplers into Layer 201. Layer 202: Deep trench exclusion layer. Minimum feature size 3 mm x 200 μm. Minimum feature spacing 3 mm. Required for deep trench layouts. Exclusion layer to allow for chip handling. Layer 203: Thermal isolation trenches. Minimum feature size 15 μm. Minimum feature spacing 15 μm. Design area 8.78 mm x 8.78 mm. 15 μm spacing to metal. 10 μm spacing to silicon. Layer 998: Dream Photonics FaML (reserved). Design area 8.78 mm x 8.78 mm. May only be used for Dream Photonics black box cells. White box cell replacement by ANT is only available for FaML cells. Please inquire with Support two weeks before MPW deadline. The image above shows the correlation of the layer numbers to each physical layer in the fabrication process. A layer definition file containing the NanoSOI layer information is available for download below. You can import the layer definition file into KLayout by choosing File, then Load Layer Properties. Design examples for tri-layer metallization, deep trench, thermal isolation trenches, and the SEM imaging layer are also available. All of our tutorials are designed to match the Layer Definition file.
Dedicated Run Options
We have many options available for custom runs. It is possible to combine many of these with standard MPW options such as direct metallization, tri-layer metallization, and deep trenches. Currently available dedicated fabrication options are listed here: - Custom cladding oxide thickness We can deposit cladding oxide thicknesses up to 3 μm. Typical oxide thicknesses are 1 μm and 2.2 μm. - Different silicon device layer thickness We have SOI wafers with the following device layer thicknesses: 145 nm, 220 nm, 300 nm, and 500 nm. As the device layer thickness increases, the minimum feature size and spacing increase to maintain a suitable aspect ratio. - Multi-layer alignment with 50 nm accuracy Multi-layer alignment can be used to accurately place metal features or create partially-etched silicon structures such as rib waveguides. - Positive-tone structures Positive tone structures include photonic crystal cavities. - Multiple silicon etch depths We can etch partially into the silicon to create structures such as rib waveguides and gratings. The etch depth can be customized, and the error in the etch depth is ± 10 nm. - Oxide via etching Windows in the cladding oxide allow for electrical connections to metal layers fabricated using the standard direct metallization option. The metal layers are deposited directly on the silicon or buried oxide layers. The window in the oxide, called the oxide via, must terminate on a metal layer. - Selective buried oxide etching The buried oxide layer can be used as a sacrificial material for micro- or nanomechanical devices. By selectively removing the buried oxide, we can release mechanical devices for optomechanics and other applications. - Custom metal levels and choices of metals We have many custom metals available including Cr, Au, Al, TiW, W, and Ni. When combined with the custom oxide cladding option, these metals can be placed at any oxide depth for electrical circuits or custom heaters. - Through-cladding windows We etch through the oxide cladding to create windows that open onto the silicon or buried oxide layers. - Deep trench with full silicon handle etch A variation on the standard deep trench process. We perform a deep silicon etch during the deep trench process to etch fully through the silicon handle layer. The end result is a smooth chip edge from the top of the cladding to the bottom of the handle. This is useful when fiber arrays with large dimensions are required for edge coupling. - Fiber bonding service Attachment of 2, 4 and 8-fiber arrays onto dies for light input/output. - Measurement services In-house semi-automatic measurement of vertically coupled devices in C-band. - Active Devices and Custom Doping Custom doping levels and species in silicon for active photonic devices (detectors, modulators, heaters, etc.).

Contract & Professional Service Providers · 201–500 employees · Taiwan
3 listed under this category
MEMS Foundry / MEMS Wafer Production
As for APM, customers are our partners. Unlike IC foundries, the work interaction between MEMS foundry and the customer is different. Because of highly customized effort for each unique device, it will require closer cooperation between the chip designer and the wafer manufacturing foundry to realize well-functional MEMS device. Over the years, APM accumulates extensive experiences in MEMS wafer production, which allows us further understanding what the customers are looking for and how we can serve them better. We welcome you to contact us for your inquiry and teaming up with us for highly potential of MEMS product. You can count on our MEMS processing expertise to assist you achieving your business success. >> Expertise - Over 25 years of professional experience in MEMS technology - Accumulating over 20 years of experience in MEMS development and production, APM ranks one of top 10 MEMS foundries in the world. With a long history working in the process development of diverse MEMS devices, in contrast to no or little experience of newly built MEMS foundries, we can better understand the problems you may encounter and then provide promptly professional technical advice or assistance in your project. Having valuable experience and knowledge in the field of MEMS production, we hope to become your preferred professional MEMS foundry partner >> Flexible MEMS Platform - APM provides a flexible MEMS fabrication platform that goes beyond the limitations of standard CMOS-based foundries, giving you greater design freedom and a faster path to production. We support a wide range of materials and process capabilities, including: - Polymer MEMS - Noble and specialty metals - Double-side wafer processing - Deep reactive ion etching (DRIE) - Wafer bonding Our modular MEMS platform allows you to rapidly develop and scale: - MEMS sensors (pressure, environmental) - MEMS actuators - Optical MEMS and silicon photonics (optical bench) - Microfluidic and BioMEMS devices >> Proven Across Industries - APM brings proven production experience across a range of multiple high-demand markets, extending beyond lab-level development to real-world manufacturing. We support applications in: - Automotive MEMS sensors - IoT sensing platforms - BioMEMS and medical devices - Optical communications and photonics By working closely with global customers, we help you: - Reduce development risk - Accelerate time-to-market - Successfully transition to volume production >> Customer’s IP Protection and Project Management Process - Systematically approach in MEMS development and holding customer’s intellectual property in high regard - APM holds every customer's intellectual property in high regard and carefully manage its operation procedure to protect each client's proprietary design and information. In addition, targeting the nature of highly customized MEMS product development, internally, APM has created its new product development procedure called APM Product Introduction Process (APIP), to systematically work toward the goals of the customer's MEMS development plan according to different stages of its project. >> One-stop Shopping - Benefits from agglomeration economies to reduce development time and costs - Hsinchu Science Park in Taiwan, has a complete electrical and electronic supply chain in the world and can offer the demand of vertical integration of any electronics product. This overall infrastructure in the area can provide the customers one-stop shopping to reduce transportation and logistics costs and precious time in production development and manufacturing. In particular, of highly fragmented MEMS industry, it requires closer integration of upstream and downstream suppliers to be competitive. APM can provide recommendations and referrals beyond the wafer level processing in a timely manner when needed, to assist the customer successfully reaching mass production of MEMS product.
Process Capability
Capability | Wafer Size | Capability | Wafer Size | 150mm | 200mm | 150mm | 200mm Photolithography: - Coater (Track) - 200mm - Coater (Double side handling) - 150mm - Coater (Spray) - 150mm, 200mm - Developer (Track) - 150mm, 200mm - Developer (Double side handling) - 150mm - Stepper - 150mm - Aligner - 150mm, 200mm - Bonder - 150mm Dry Etching: - Si DRIE - 150mm - Polysilicon - 150mm - Dielectric - 150mm, 200mm - Metal - 150mm - Glass DRIE - 150mm, 200mm Wet Etching: - Wafer clean - 150mm - Si - 150mm - Silicon oxide - 150mm - Silicon nitride - 150mm - Metal - 150mm - Lift-off - 150mm, 200mm - PR strip - 150mm, 200mm Sputter: - Metal sputter - 150mm - Reactive sputter - 150mm Evaporator: - Metal - 150mm, 200mm Electroplating: - Cu plating - 150mm PECVD: - Amorphous silicon - 150mm - Silicon oxide - 150mm, 200mm - Silicon nitride - 150mm, 200mm - Silicon carbide - 150mm - PSG - 150mm - BPSG - 150mm Furnace: - Thermal oxidation - 150mm - Anneal - 150mm - Alloy - 150mm LPCVD: - Polysilicon - 150mm - Silicon nitride - 150mm Ion Implanter: - Medium current - 150mm - High current - 150mm Grinding: - Coarse grinding - 150mm - Fine grinding - 150mm - Ultra-fine grinding - 150mm Blade Dicing: - Silcion dicing - 150mm - Glass dicing - 150mm Laser Dicing: - Stealth laser dicing (silicon) - 150mm Pick&Place: - Pick&Place - 150mm WAT / CP test: - Prober - 150mm - Manual station - 150mm Metrology: - CD SEM - 150mm - Ellipsometer / Nanospec - 150mm - Stress meter - 150mm - Surface profiler - 150mm - 3D profiler - 150mm - IR microscope - 150mm - White-light interferometer - 150mm
MEMS Express: Standard Process Platforms
"One Product, one process" is one of the key features of the MEMS industry. MEMS wafer foundry develops and creates dedicated and robust wafer manufacturing process in accordance to its unique design of each device. In general, it takes more than one year. However, the designs and process requirements of certain types of MEMS products are getting more and more alike after the evolution in years. Working as a pure-play MEMS foundry, APM consolidates and proposes the standard process platforms to assists our customers to shorten the development period, to reduce the development cost and to facilitate fast time-to-market. With extensive experiences in MEMS wafer production, we provide the pre-defined and robust manufacturing processing flow & parameters for certain MEMS devices proactively, but still offer enough flexibility in design changing and/or adding other performance features to create your own highly potential MEMS product. We call it "MEMS Express". In further, APM has been working on creating a series of reference devices ready for production. You simply check the genetic specifications to make sure those devices meet your applications. With little or no modification, APM can offer these devices to you in a short period of time.
Academic & Research Institutions · United States
2 listed under this category
Nanofabrication Facility Access
The ASRC Nanofabrication Facility undertakes collaborative multidisciplinary projects centered around creating novel devices and interfaces. Examples of past and ongoing projects include miniature electrical circuits for quantum computing applications, microfluidic devices to create lab-on-chip platforms, microneedle arrays to interface with individual cells, micro electromechanical pressure sensors, nano-coatings, and many others. The possibilities are virtually endless! To create these devices we routinely use a variety of lithographic techniques that produce patterns which span eight orders of magnitude: from several nanometers to centimeters in size. These patterns are subsequently used to either deposit materials, such as metals, glasses, or ceramics, or to etch these materials with nanometer precision. The facility is also supported by an imaging suite, that consists of a cryogenic TEM for life sciences, a materials science TEM, a training TEM, and a dual beam SEM / FIB / Nanomanipulator system for sample preparation. For users, the facility provides an opportunity to carry out hands-on research with some of the world's most sophisticated instruments for the fabrication and characterization of materials at the micro and nanoscale. The Nanofabrication Facility is a highly collaborative research space located on the ground floor of the Advanced Science Research Center at The Graduate Center, CUNY. The facility is home to dozens of interdisciplinary research teams from many diverse sectors of academia and industry. Our mission is to facilitate scientific discoveries and development of new technology by providing both mentorship and access to a state of the art nano-manufacturing environment. Usage Rates Rates effective July 1, 2026 Internal Academic (CUNY) Members - Monthly Cap: $1,800 per month - Daily Access Fee: $10 per day with a maximum charge of $150 per month External Academic Members - Monthly Cap: $2,000 per month - Daily Access Fee: $15 per day with a maximum charge of $200 per month Start-Up Members - Daily Access Fee: $20 per day with a maximum charge of $300 per month Industrial Members - Daily Access Fee: $30 per day with a maximum charge of $450 per month
Chemical Hoods
Resist Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) Litho Development Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) Solvent Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) Piranha/HF Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) Caustics/Metal Etch Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) RCA Hood Air Control $ / Hour: $ 5 (CUNY Rate), $ 10 (Outside Academic), $ 30 (Start-Up Companies), $ 50 (Industrial Companies) Spin Rinse Dryer OEM Group $ / Hour Single use charges for the Solvent Hood will be capped at $15 for internal academic members, $25 for external academic members, $50 for start-up members, and $75 for industrial members, in order to accommodate extended lift-off processes. Note that this only applies to the Solvent Hood as lift-off should not be performed in other hoods.

Equipment & Instrumentation Manufacturers · 11–50 employees · Denmark
2 listed under this category
A-HUB: Sovereign AI-to-Matter Infrastructure
A-HUB is ATLANT 3D’s deployable sovereign infrastructure for Physical AI, the physical execution and verification layer that transforms AI-designed materials into validated processes, functional devices, and industrial capabilities. Powered by ATLANT 3D’s proprietary Direct Atomic Layer Processing (DALP ® ) technology and NANOFABRICATOR ® systems, A-HUB brings the complete materials-development loop into one integrated environment. It connects AI-driven design and physical translation with atomic-scale material synthesis, metrology, validation, and continuous data feedback. Within an A-HUB, partners can move from material concepts and digital designs to validated process recipes, functional device prototypes, and pilot manufacturing workflows. Hardware, software, process intelligence, materials and process IP, characterization, and expert foundry capabilities operate as one coordinated platform, accelerating the journey from discovery to industrial deployment. - Prototyping & Testing: From individual prototypes to small-batch production - Scalable Fabrication: From individual prototypes to small-batch production - Specialized Resources: From individual prototypes to small-batch production
A-HUB
ATLANT 3D’s ON-SITE R&D AND MANUFACTURING CAPABILITIES ATLANT 3D is transforming the electronics industry by significantly reducing the time it takes to bring new products to market. Our innovative approach enables us to compress the development timeline from decades to just one year, allowing you to rapidly transform your ideas into marketable products. Discover how ATLANT 3D can support your R&D projects and lab-scale advanced prototyping in our A-HUB facilities, enabling rapid prototyping, pilots and feasibility studies. Rapid Prototyping A-HUB accelerates the journey from concept to prototype reducing development time dramatically. Bespoke Solutions Tailored projects and customized manufacturing meet the unique needs of every client. Expert Collaboration Gain access to a team of experts in atomic layer processing material science and more. Innovative Technology Utilize ATLANT 3D’s cutting-edge DALP ® technology for unmatched precision and efficiency. A-HUB: Driving Collaborative Innovation in Nanotechnology A-HUB serves as a nexus for collaboration, research, and development in micro and nanotechnology. It is designed to foster partnerships and co-development projects, leveraging our groundbreaking DALP ® technology and NANOFABRICATOR machines. A-HUB is where ideas converge, and future technologies are born. Cooperation opportunities: - Joint product development: Partner with us to co-develop new electronics products. - Manufacturing outsourcing: Leverage our advanced manufacturing capabilities to produce your products efficiently. - Technology transfer: Gain access to our proprietary technology through licensing or joint development. A Diverse Array of Industries at A-HUB A-HUB serves a broad spectrum of industries, from semiconductor manufacturing to advanced material research, and aerospace to medical technology. Our versatile approach makes A-HUB an ideal partner for sectors that demand the utmost precision and innovation. Engaging with A-HUB opens up a world of possibilities. Whether you’re looking to bring a groundbreaking idea to life or seeking to leverage the latest in atomic layer manufacturing, A-HUB is your gateway. Connect with us to discover how A-HUB can transform your ideas into reality and join the forefront of manufacturing innovation.

Contract & Professional Service Providers · 51–200 employees · United States
5 listed under this category
Microfabrication Foundry Services
A manufacturable path from prototype to production. Atomica is a U.S.-based microfabrication foundry that turns advanced device concepts into manufacturable, scalable hardware — and its advantage is not a single process but a system that de-risks the path from first prototype to volume. 30,000 sq ft cleanroom · Class 100 · ISO 9001 certified · ITAR registered · Santa Barbara, USA Engineering Collaboration: Atomica works as an engineering partner across design, materials, fabrication, and testing, bringing diverse expertise together to optimize each micro-scale device. That collaboration is what yields better products, lower cost, faster time-to-market, and quicker adaptation to emerging technologies. Process Standardization: Standardized processes give a clear framework for fabrication, scaling, and quality control. This is what delivers the consistency, quality, and efficiency that reliable, high-performance microdevices require — while supporting regulatory compliance and continuous improvement. Modeling & Simulation: Atomica evaluates designs before fabrication using physics-based modeling, FEA, CFD, AI, and multiphysics simulation. Simulating first reduces prototype iterations, lowers cost, identifies risks early, and improves first-pass success across photonics, sensors, biotech devices, MEMS, and integrated microsystems. AI Optimization (FabOps): Atomica’s FabOps system applies AI and advanced analytics across wafer inspection, metrology, fab control, and project execution. By integrating equipment, process flows, pricing, projects, and manufacturing — with real-time visibility, lot tracking, and change control — it reduces risk and accelerates programs from prototype to scalable production. Fab Technology: Atomica operates a 30,000 sq ft, class-100 cleanroom near Santa Barbara, California — ISO 9001 certified and ITAR registered. Its full in-house process suite spans photolithography, deposition, dry and wet etch, bonding, plating, metrology, testing, dicing, and planarization, purpose-built for rapid prototyping and scalable production.
Non-CMOS MEMS Foundry
As the leading MEMS foundry in the U.S., Atomica is perfectly suited to work with companies that need to utilize these materials. Since we do not produce transistors, we are not at risk of contaminating CMOS devices. Additionally, our 20+ years of experience and knowledge in working with these materials allows us to safely and efficiently accommodate the diverse requirements of our clients. Here’s a snapshot of how Atomica can handle the challenges of non-CMOS materials: Magnetic Materials (NiFe): Disrupt device operation and measurement tools -- Extensive experience with magnetic materials in a non-CMOS environment High-Mobility Metals (Au): Cause junction leakage or shorting if they diffuse into silicon -- Specialized handling and prevention measures to control diffusion Alkali Metals (Na): Diffuse easily into SiO 2 and silicon, leading to device instability -- Utilizing alternate materials and strategies to minimize risk Certain Polymers (Polyimide): May outgas or have components that contaminate the CMOS process -- Implementing strategies to prevent outgassing and contamination Heavy Metals (Pb): Create deep-level traps in silicon, causing leakage currents and affecting device performance -- Handling and containment protocols to prevent contamination III-V Semiconductors (GaN, InP, GaAs): Their differing temperature, contamination risk, and lattice structure make integration challenging -- Long-standing expertise in integrating III-V semiconductors Piezoelectric Materials (AlN, PZT, LiNbO 3, LiTaO 3): Require specific processing conditions and contain elements that can potentially contaminate CMOS devices -- Experience with diverse piezoelectric materials and associated processing conditions Reactive Compounds (Phosphorus compounds): Disrupt the properties of the CMOS devices -- Handling processes designed to prevent disruption of CMOS properties Additional Noble Metals (Ag, Pt, Pd, Ru): Can diffuse into silicon and disrupt device operation -- Extensive experience handling noble metals in a non-CMOS setting At Atomica, we are ready to help you innovate, and our specialized non-CMOS foundry capabilities are unmatched. As the world of semiconductors continues to evolve, you can count on us to enable your success by ensuring the safe and effective use of the full richness of the periodic table.
8-inch (200mm) Wafer Fabrication
Atomica (formerly IMT) officially announced today that we're offering 8-inch (200mm) wafer fabrication capabilities, marshaling in a new era in the company's ability to serve the growing MEMS industry. 200mm capabilities improve the economics of MEMS production by yielding roughly twice the number of devices per wafer. Bringing 8-inch capabilities to customers is another milestone in the ongoing capital improvements driven by the recent round of investment in the company last fall. Atomica continues to upgrade its 130,000 ft2 manufacturing campus and 30,000 ft2 class 100 wafer fabrication clean room.
Volume Foundry Service
30,000-square-foot class 100 cleanroom fab for manufacturing 6″ and 8″ wafers. Technical expertise in photonics, sensor, biotech and MEMS design, prototyping, and process development. Complete analytical, metrology, and test capabilities for high-volume manufacturing with statistical quality control and statistical process control. Volume foundry service for photonics, sensor, biotech and MEMS-specific or other wafer processing work. Flexibility to develop and bring in new technologies.
In-House Fabrication
Atomica operates a 30,000-square-foot Class 100 cleanroom near Santa Barbara, California, with ISO 9001 certification and ITAR registration. The facility supports a broad range of materials and capabilities, backed by advanced process control, AI-driven inspection, precision metrology, and proprietary fab operations systems. When paired with Atomica’s in-house fabrication capabilities, simulation helps reduce development risk and shortens time-to-market across diverse microfabrication use cases.

Contract & Professional Service Providers · 1–10 employees · Sweden
1 listed under this category
Clean room services
By providing clean room services, our customers will have a chance for rapid and iterative prototyping that is crucial for the business development.

Academic & Research Institutions · 1,001–5,000 employees · United States
1 listed under this category
Cleanroom Use
A Class 1,000 cleanroom contains fewer than 1,000 airborne particles measuring 0.5 micrometers or larger per cubic foot of air. A Class 10,000 cleanroom contains fewer than 10,000 such particles per cubic foot of air. The lab is supported by an air-handling system that filters the equivalent of the facility’s entire air volume every 45 seconds. Usage is open to Boston College faculty and students, as well as external users. You do not have to be part of the Boston College community to rent equipment in this space. Cleanroom Use: Internal Rates (Boston College) $32/hr; External Academic Rates (non profit) $32/hr; External Commercial Rates $60/hr