NW

Instrument Access

Self-operated rental of characterization tools.

101 providers565 listings24 countries
← All services

Showing all 101 providers

4SpinVerified

Equipment & Instrumentation Manufacturers · 201–500 employees · Czech Republic

1 listed under this category

4SPIN TRIAL PROGRAM

Contipro is proud to offer a one or two day trial program designed for you to experience the 4SPIN LAB in the comfort and presence of its creators. You are welcome to bring your own samples to test before you invest. Our purpose built 4SPIN demonstration laboratory is located 1.5 hours east of Prague. For further information including the T&C’s please email us at support@4spin.info.

Advanced Institute for Materials Research (AIMR), Tohoku UniversityVerified

Academic & Research Institutions · 201–500 employees · Japan

2 listed under this category

Common Equipment Room

Located inside the AIMR Main Building, the Common Equipment Room provides access to the standard experimental apparatus widely used in preparing and evaluating materials. The facilities offer a comprehensive research environment, and dedicated technical coordinators are on hand and manage equipment to reduce the administrative burden on laboratories and allow researchers to focus on their research. By uniting equipment maintenance and management in one facility, we aim to contribute to improving the quality of research by providing an optimal environment for the use of research apparatus. As well as looking after equipment, technical coordinators also provide any necessary support for the introduction of equipment and other technical support to help researchers achieve their goals. Tohoku University provides a system that allows the shared use of equipment throughout the university. In addition to helping researchers to use these shared facilities, AIMR’s coordinators collaborate with the Core Facility Center (CFC) to provide a comprehensive range of services matched to the needs of researchers and technicians, including use of equipment and technical consultation across the university. Major Equipments - FE-SEM (Field-emission Scanning Electron Microscope); JEOL, JSM-7800F - Sputtering System: ULVAC, QAM-4-S - Laser Raman Spectrometer; HORIBA, LabRAM HR-800 - TG-DTA, DSC (Thermal Analysis Apparatus); RIGAKU, Thermo plus EvoII - Xray Diffraction Measurement System (XRD); RIGAKU, SmartLab 9MTP - Xray Diffraction Measurement System (Laue Camera); RIGAKU, RASCO 3M etc.

Computation-Aid Unit

Obtaining and maintaining computers places a heavy burden on many research labs. The Computation-Aid Unit provides support with these needs, in particular to experimental research labs and young researchers. By providing access to shared core infrastructure and operational expertise, the unit helps research labs and researchers by reducing the burden of introducing computational servers, allowing researchers to focus more on their research. This helps newly appointed researchers to immerse themselves in their work as quickly as possible after taking up their positions. Additionally, we offer a wide range of solutions tailored to the needs of researchers, such as providing customized computational resources to research labs and offering technical advice to young researchers.

AIM PhotonicsVerified

Contract & Professional Service Providers · 201–500 employees · United States

1 listed under this category

TAP Tools

TAP Tool Levels Level 1 Tools Metrology & Test - Sputter Prep for SEM - Polishing Setup (SEM Cross-Section) - Thermal Microscope - Reflectance Spectrometer (Thickness Measurement) - Diff Scanning Calorimetry - Confocal Scanning Acoustic Microscope - Laser Confocal Microscope - NIR Microscope - Spectroscopic Ellipsometer - Optical Backscatter Interferometer - Optical Vector Analyzer - UV/Vis Spectrophotometer - EO Test Instruments - General Assembly - General Support Tools - Interferometer (Connected Fibers) - Fiber Prep and Fusion Splice - Die Pick and Place - Fiber Taper Manufacturing - Automated N2 Oven Wafer Processing - Film Laminator - Plasma Ash - Tape Frame Applicator 300mm - Laser Die Marker - Reflow Tool Level 2 Tools Metrology & Test - X-ray Tomography - EO Test Instruments - High Speed Assembly - Adhesive Dispenser - Large Bake Oven - High Volume Wire Bonder (requires tooling) - Mechanical Dicing Saw Wafer Processing - Laser Dicing - Single Wafer flux cleaner - Coater/Developer - Wet Metal Etch and PR strip Level 3 Tools Metrology & Test - SEM/Dual-Beam - Wafer/Die Prober (Optoelectronic test) Assembly - Laser Fiber Cleaver - Atmospheric Plasma Cleaner - Flip Chip - Semi-Automated Wire Bonder (prototype) - Chip Level Fiber Attach System - Solder Ball Jetter Wafer Processing - Plasma Dicing - Lithography Exposure - PVD/Sputtering

Ambrell Precision Induction HeatingVerified

Equipment & Instrumentation Manufacturers · 51–200 employees · United States

1 listed under this category

Equipment Rental Program

Would you like to try induction heating in your facility before buying a system? Is it currently challenging to get a capital equipment expenditure approved? Or do you simply need a system for a limited period of time? Then you should consider Ambrell’s Equipment Rental Program. You can choose to “rent-to-own” or rent a system for a finite period of time. Your system will be backed by Ambrell’s standard equipment warranty for the duration of the rental. For additional details, please fill out the form and we’ll get back to you to discuss your requirements.

NO LOGO
ASRC Nanofabrication FacilityVerified

Academic & Research Institutions · United States

1 listed under this category

Metrology

Scanning Electron Microscopy FEI NovaNano 450 $ / Hour: $ 35 (CUNY Rate), $ 40 (Outside Academic), $ 120 (Start-Up Companies), $ 200 (Industrial Companies) Atomic Force Microscopy Bruker Dimension FastScan $ / Hour: $ 30 (CUNY Rate), $ 35 (Outside Academic), $ 105 (Start-Up Companies), $ 175 (Industrial Companies) Surface (Stylus) Profilometer Bruker Dektak-XT $ / Hour: $ 25 (CUNY Rate), $ 28 (Outside Academic), $ 84 (Start-Up Companies), $ 140 (Industrial Companies) Optical Profilometer Bruker Contour GT-I $ / Hour: $ 18 (CUNY Rate), $ 20 (Outside Academic), $ 60 (Start-Up Companies), $ 100 (Industrial Companies) Ellipsometer J. A. Woollam V-VASE $ / Hour: $ 28 (CUNY Rate), $ 32 (Outside Academic), $ 96 (Start-Up Companies), $ 160 (Industrial Companies) Thin Film Analyzer Filmetrics $ / Hour

Bionano Genomics, Inc.Verified

Equipment & Instrumentation Manufacturers · 201–500 employees

1 listed under this category

Bionano Compute On Demand

Reduce infrastructure costs and increase your OGM capacity. Bionano Compute On Demand is a pay-per-use solution accessible through Bionano Access web server for Bionano Solve operations. Compute On Demand simplifies the way you perform OGM data analysis from the Saphyr™ or Stratys™ instruments without the need for any additional infrastructure, providing the flexibility and scalability your experiment deserves. Advantages include the ability to: * Analyze large genomes and a high number of samples simultaneously * Perform pipeline analysis operations without worrying about server capacity * Protect data via encryption for secure operations * Ensure data center compliance with IPAA, CSA, SOC2, and ITAR regulations Control access to genomic data for end-users Bionano Compute On Demand requires Bionano Access 1.6.1, which is available on our Software Downloads page. Compute On Demand * Execute variable workloads * Requires no upfront server costs * No on-site compute infrastructure set up * Optimized for human genomes

Boston College - Integrated Sciences Cleanroom and Nanofabrication FacilityVerified

Academic & Research Institutions · 1,001–5,000 employees · United States

5 listed under this category

Deposition Equipment Access

Sputter Deposition System, AJA International Orion 8 - Internal $40/hour; External Academic $40/hour; External Commercial $95/hr. Benchtop Sputter Deposition, Safematic CCU - Internal $10/run; External Academic $10/run; External Commercial $25/run. Atomic Layer Deposition, Ultratech - Internal $15/hr; External Academic $15/hr; External Commercial $50/hr. Thermal Evaporator, Kurt J. Lesker PVD-75 - Internal $10/hr; External Academic $10/hr; External Commercial $45/hr. PE-CVD, Plasma-Therm Vesaline LL - Internal $40/run; External Academic $40/run; External Commercial $95/run. E-Beam Deposition (w/ion source), Ångstrom Amod - Internal $75/hr; External Academic $75/hr; External Commercial $150/hr. Benchtop Sputter Coater, Safematic CCU - Internal $15/hr; External Academic $15/hr; External Commercial $50/hr. Electroplating System, Reynolds Tech - included in General Cleanroom Use rate.

Metrology Equipment Access

Scanning Electron Microscope, JEOL JSM-7001F - Internal $44/hr; External Academic $44/hr; External Commercial $105/hr. EDX (on SEM), Oxford - included in SEM rate. Optical Microscope (High Power), Olympus BX61. Reflectometer, Mission Peak Optics MP100-S - included in General Cleanroom Use rate. Surface Profilometer, Veeco Dektak 150 - included in General Cleanroom Use rate. Spectroscopic Ellipsometer, J.A.Woollam Vertical VASE. RF LCR Meter, Agilent 4287A - included in General Cleanroom Use rate. Probe/Test Station, Cascade Microtech M150. Four Point Probe Station, Jandel MHMP/RMS-AR - included in General Cleanroom Use rate.

Lithography Equipment Access

Mask Aligner, OAI Model 200 - included in General Cleanroom Use rate. Spin Coater, Laurell WS-650 - included in General Cleanroom Use rate. Spin Coater, Laurell WS-400E - included in General Cleanroom Use rate. Hot Plates (2) - included in General Cleanroom Use rate. Thermal Scanning Probe Lithography (t-SPL) system, Heidelberg Instruments Nanofrazor Scholar - Internal $15/hour; External Academic $15/hour; External Commercial $34/hour. Direct Write Maskless Aligner, Heidelberg Instruments µMLA - Internal $10/hour; External Academic $10/hour. YES-310TA HMDS Oven - included in General Cleanroom Use rate.

Heat Treatment and Back-End Equipment Access

Dicing Saw, DiscoUSA DAD3220 - Internal $16/hr; External Academic $20/hr; External Commercial $65/hr. Wire Bonder, West-Bond Model 747630E - Internal $10/hr; External Academic $15/hr; External Commercial $35/hr. Atmospheric Furnace, Lindberg/Blue M 3-Zone Tube Furnace STF55666C - Internal $15/hr; External Academic $20/hr; External Commercial $50/hr. Rapid Thermal Processor, Allwin21 RTP - Internal $10/hr; External Academic $10/hr; External Commercial $20/hr. General Purpose Oven (2) - included in General Cleanroom Use rate. Vacuum Oven (2) - included in General Cleanroom Use rate.

Etch Equipment Access

Samco RIE-10NR - Internal $40/hr; External Academic $40/hr; External Commercial $95/hr. XeF2 Etch System, XACTIX X-SYS- EXP Xetch - Internal $15/hr; External Academic $20/hr; External Commercial $50/hr. Acid Etching Fume Hood, Reynolds Tech FWS-196-4910 - included in General Cleanroom Use rate. Microwave Plasma Etch, PVATePla PS-210 - included in General Cleanroom Use rate. Solvent Cleaning Fume Hood, Reynolds Tech FWS-196-SS - included in General Cleanroom Use rate.

Carnegie Mellon UniversityVerified

Academic & Research Institutions · United States

42 listed under this category

Mass Spectrometry Facility - Mass Spectrometer Access

Bruker Ultraflextreme MALDI TOF/TOF MS. The Bruker UltrafleXtreme is a MALDI (Matrix-Assisted Laser Desorption Ionization) time of flight (TOF) TOF mass spectrometer. It uses delayed-extraction for linear mode, reflectron mode and MS/MS (TOF/TOF using LIFT mode) scans. Gas phase ions are formed via laser ablation and desorption of a solid chemical matrix/analyte sample, and are subsequently accelerated down a 2-meter flight tube. The flight trajectory of the ions in the tube can be modeled kinematically, therefore relating the time of flight to the mass to charge ratio (m/z) of the ion. The matrix compound is typically a small organic molecule, chosen for its ability to absorb photons at 355 nm from the frequency-tripled Nd: YAG laser. In reflectron mode the UltrafleXtreme has high mass resolving capabilities up to 40,000 and ppm mass accuracy. The UltrafleXtreme is also designed for TOF/TOF, a two stage, tandem mass spectrometry technique that can generate and record MS/MS or MS 2 spectra. The incorporated LIFT device allows full fragment ion spectra to be acquired within a single scan. Typical analytes are biomolecules, nanoparticles, and synthetic polymers. System Overview: - Smartbeam laser acquisition speeds: Max laser rep rate of 2000Hz for MS; Max laser rep rate of 1000Hz for MS/MS - Reflectron mode: Resolution up to 40,000; 1 ppm mass accuracy - Linear Mode: Resolution up to ~2500 - MS/MS or TOF/TOF mode:(LIFT mode) Mass spectra can be acquired with up to 1000 Hz laser repetition rate from low fmol levels within seconds. - Laser: Solid state frequency-tripled Nd: YAG laser at 355 nm with a Gaussian beam profile. - Digitization rate:sample rate of up to 4 GS/sec. - For MS Imaging work: Laser focus diameters down to 10 microns for the best spatial resolution imaging; Max laser rep rate of 2000Hz for MS; Max laser rep rate of 1000Hz for MS/MS Sample Preparation: - Sample and matrix should be prepared in similar or miscible solvent systems. - Preparation typically only requires 1µL of sample - Selecting the proper matrix has a large effect on results. This decision can be based on previous successful MALDI analyses of similar samples, the NIST polymer recipes page for polymer samples, or see the general guide found in the Voyager manual (section 3.1.1 - "Selecting a Matrix"). Sinapic acid is the most common protein (>10kDa) matrix used. α-cyano-4-hydroxycinnamic acid is the most common peptide (<10kDa) matrix used. - Samples must be completely dry before loading into the instrument. - For positive ion samples, a small amount of acetic acid or TFA (0.1% v/v) can be added to enhance the signal. - Approximate recommended sample concentrations are as follow: Small peptides: 1-10 pmol/µL; Proteins: 1-50 pmol/µL; Polymers: 1-10 mM HTX Matrix Sprayer for MS imaging. The HTX-TM Spray is a spray-based MALDI sample preparation system that is used to create highly homogenous uniform matrix depositions on a mass spectrometry sample. Mass Spectrometry Imaging (MSI) is a multidimensional MS technique that is used to visualize the spatial distribution of molecules across a sample. To accurately assess molecules across a mass spectral image, the matrix must be deposited equally along all parts of the sample, eliminating “sweet-spots” and inhomogeneities that may exist upon matrix and analyte deposition. The HTX-TM system is a sprayer-based system that allows for uniform, fast, and robust deposition of matrix across a sample. The device can be programmed to control flow rate, temperature, and pressure. Each of these factors play a role in mixing and deposition of matrix onto the sample so that a high quality MS image will result. System Overview: - Sub 20-micron matrix droplets - Highly reproducible and uniform droplet deposition - Fast sample prep (10-20 minutes per plate) - Validated for most conventional MALDI matrices and trypsin digestion - Ability to edit and save method files - Temperature (up to 130ºC) and gas (up to 30 PSI pressure) can be controlled to improve crystal formation and drying. - Large flow rate range from 5µL/min – 5mL/min Thermo Scientific LTQ-XL Linear Ion Trap Mass Spectrometer + Thermo Scientific EASY-nLC 1200 Nanoflow Liquid Chromatograph. The Thermo Scientific LTQ-XL is a linear ion trap (LIT) mass spectrometer with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) capabilities. The LTQ-XL has MSn capabilities, which is a powerful analytical tool for use in structural analysis. This mass spectrometer can provide molecular weight and sequence information for small peptides (MW below 2000 Da) at the femtomole level with proper analyte introduction. Additionally, liquid seprations prior to MS detection can be made possible by coupling to the Thermo Scientific EASY-nLC 1200 liquid chromatograph with precise gradient flow (water/acetonitrile only) from 20 nL/min to 2 µL/min with pressures up to 1200 bar. Calibration: Automated system calibration performed by CMA staff only System Overview: - Mass Ranges: 15-200 Th, 50-2000 Th, 200-4000 Th - Resolution: 0.05 FWHM with Ultra ZoomScan - Sensitivity: 250 femtogram reserpine in 1:1 isopropanol:water at 400µL/min flow rate for both MS/MS and MSn. - ZoomScan for isotopic resolution across full-range scan - Ultra ZoomScan for ultimate resolution - Turbo Scan for ultra-fast scan to improve signal-to-noise and sampling rate - Positive/negative ionization modes - Multiple Ionization Strategies: Electrospray Ionization (ESI); Nanoelectrospray Ionization (nESI); Direct Analysis in Real Time (DART) - Pulsed Q Collision Induced Dissociation (PQD) enables trapping of low mass fragment ions. - High Resolution Isolation allows for the separation of an isobaric interfering species down to 0.3 Da or for isolation of thermally labile compounds. - Automatic Gain Control (AGC) used to ensure ideal number of ions stored in linear ion trap each scan. - MS n for n=1 to 15 for structural analysis - Advanced Data Dependent Experiments possible (i.e. Triple Play, Neutral Loss, Ion Tree) - Linear ion trap with radial ejection. Dual conversion dynode detectors used to capture high capacity of the ion signal. NanoLC Overview: - Pressure range: 0-1200 bar - Flow range: 20-2000 nl/min (Recommended: 100-1000 nL/min) - Samples injected via autosampler - Software integration with MS and instrument control using Xcalibur 4.0 - NanoViper fitting technology enables low dead volume liquid flow path connectivity. Minimizes peak broadening due to mixing. - nano-ESI ionization source developed in-house utilizes a 10 µm emitter. Thermo Scientific Exactive Plus EMR Orbitrap Mass Spectrometer + Thermo Scientific Vanquish Flex Binary UHPLC. The Thermo Scientific Exactive Plus EMR is a Orbitrap-based electrostatic ion trap mass spectrometer with electrospray (ESI), nanoelectrospray (nESI), and direct analysis in real time (DART) ionization capabilities. The Exactive Plus EMR has high resolution and accurate mass (HRAM) capabilities, providing high confidence molecular weight determinations. This mass spectrometer can provide molecular weight information for small molecules at the femtomole level with proper analyte introduction. Additionally, liquid seprations prior to MS detection can be made possible by coupling to the Thermo Scientific Vanquish Flex Binary UHPLC with precise gradient flow from 0.001-8 mL/min with pressures up to 15,000 psi. Calibration: Automated system calibration performed by CMA staff only System Overview: - Mass Ranges: 50-6,000 Th (standard mode), 350-20,000 Th (EMR mode) - Resolution: Up to 140,000 (FWHM) @ m/z 200 - Mass Accuracy: Standard mode: <1 ppm RMS (internal); <3 ppm RMS (external); EMR mode (external): <3 ppm RMS (350-6,000 Th); <5 ppm RMS (6,001-10,000 Th); <10 ppm RMS (10,001-15,000 Th) - Sensitivity: 500 fg buspirone on-column S/N 100:1 acquired with H-ESI II probe - Max scan rate: Up to 12Hz at mass resolution setting of 17,500 @ m/z 200 - Positive/negative ionization modes - All-ion-fragmentation (AIF) with either: In-source collision-induced dissociation (CID); Higher-energy collisional dissociation (HCD) - Multiple Ionization Strategies: Electrospray Ionization (ESI); Nanoelectrospray Ionization (nESI); Direct Analysis in Real Time (DART) UHPLC Overview: - Pressure range: 290-15,000 psi - Flow range: 0.001-8 ml/min - Samples injected via autosampler - Software integration with MS and instrument control using Xcalibur 4.0 - NanoViper fitting technology enables low dead volume liquid flow path connectivity. Minimizes peak broadening due to mixing. Applied Biosystems Voyager DE-STR MALDI-TOF. Applied Biosystems (formerly PerSeptive Biosystems) Voyager STR MS is a matrix assisted laser desorption ionization (MALDI) time of flight (TOF) mass spectrometer. Ions are formed in the gas phase from a laser focused onto a matrix/analyte solid sample. The matrix compound is typically a small organic molecule, chosen for its ability to absorb photons at 337 nm from the nitrogen laser. Gas phase ions (positive ions are typically protonated) are then accelerated down the 2 meter flight tube with 20-25 keV of kinetic energy (KE). Low m/z ions hit the detector first followed by the slower, higher m/z ions. To a first order, the ions follow the equation KE=1/2mv 2. Typical analyte molecules include polymers, peptides, proteins, and DNA. Funded by NSF grant #CHE-9808188 Calibration: Must be performed on a per-session basis by each individual user System Overview: - Mass range 1-400,000 Da - Positive and negative ion modes - Linear (R=3000) and reflector (R=15000) modes - Post-source decay (PSD) with CID - 337nm nitrogen laser - 100 well standard sample plate (user-supplied) - Polymeric analysis tool (PDI, M n, M w, M z calculation) - 5ppm mass accuracy in reflectron mode with internal reference - Femtomole-level detection with proper sample preparation Thermo-Fisher LCQ ESI/APCI Ion Trap. The Finnigan LCQ is a quadrupole field ion trap mass spectrometer with electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources. The LCQ has MSn capabilities, which is a powerful analytical tool for use in structural analysis. This mass spectrometer can provide molecular weight and sequence information for small peptides (MW below 2000 Da) at the femtomole level with proper analyte introduction. Calibration: Done by CMA staff only System Overview: - Optimum mass range 50-2000 m/z, 4000 m/z in limited capacity - Resolution of >1000 across optimum mass range on a full MS scan - Zoom and turbo scan features - Positive / negative ion modes - ESI and APCI sources - MS n (i.e. MS-MS-MS-...) mode for structural analysis - LC-MS capability - Protein identification with SEQUEST software - Deconvolution tool for protein mass measurement

Liquid Chromatography and LC/MS Analysis (Vanquish Flex Binary UHPLC with Exactive Plus EMR)

The Center has two LCs available for LC/MS. Both LCs can be couple to our three ESI MSs and are intend to be primarily used in hybrid fashion rather than individually. The Easy-nanoLC 1200 currently sits next to the ThermoFisher Scientific LTQ MS and our ThermoFisher Scientific Vanquish Flex LC sits next to our ThermoFisher Scientific Exactive EMR MS. The Thermo Scientific Vanquish Flex Binary UHPLC is a liquid chromatograph capable of precise, binary gradient flow from 1 µL/min to 8 mL/min with pressures up to 15,000 psi. For LC-MS, the Vanquish Flex Binary UHPLC is coupled to a Thermo Scientific Exactive Plus EMR Orbitrap mass spectrometer with nanoelectrospray (nESI), electrospray (ESI), or direct analysis in real time (DART) ionization capabilities. The Exactive Plus EMR has high resolution and accurate mass (HRAM) capabilities for high confidence molecular weight determinations. This mass spectrometer can provide molecular weight and sequence information for small molecules at the femtomole level with proper analyte introduction. Additionally, the Exactive Plus EMR provides extended mass range (EMR) capabilities up to m/z 20,000 for the analysis of large macromolecules (e.g. nanoparticles, protein/protein complexes, polymers). Sample Preparation: - Filtered - Degassed UHPLC Overview: - Pressure range: 290-15,000 psi - Flow range: 0.001-8 ml/min - Samples injected via autosampler - Software integration with MS and instrument control using Xcalibur 4.0 - NanoViper fitting technology enables low dead volume liquid flow path connectivity. Minimizes peak broadening due to mixing. MS Overview: - Mass Ranges: 50-6,000 Th (standard mode), 350-20,000 Th (EMR mode) - Resolution: Up to 140,000 (FWHM) @ m/z 200 - Mass Accuracy: Standard mode: <1 ppm RMS (internal); <3 ppm RMS (external); EMR mode (external): <3 ppm RMS (350-6,000 Th); <5 ppm RMS (6,001-10,000 Th); <10 ppm RMS (10,001-15,000 Th) - Sensitivity: 500 fg buspirone on-column S/N 100:1 acquired with H-ESI II probe - Max scan rate: Up to 12Hz at mass resolution setting of 17,500 @ m/z 200 - Positive/negative ionization modes - All-ion-fragmentation (AIF) with either: In-source collision-induced dissociation (CID); Higher-energy collisional dissociation (HCD) - Multiple Ionization Strategies: Electrospray Ionization (ESI) -- (Thermo Scientific Ion Max Source); Nanoelectrospray Ionization (nESI) -- (Thermo Scientific Nanospray Flex Source); Direct Analysis in Real Time (DART) -- (IonSense DART-OS Source) - Automated system calibration performed by CMA staff only

Xenocs Xeuss 3.0 SAXS/WAXS Access

This instrument supports the development of cutting-edge nanostructured materials that have keys features ranging in size from Angstroms to hundreds of nanometers. To enable in situ and in operando characterization of structural properties, this custom, automated Xenocs Xeuss 3.0 x-ray scattering system will enable high-throughput studies at a variety of length scales. Specifications Dynamic WAXS to SAXS and USAXS to enable probing of d-space lengths ranging from 2 Angstroms to 4.5 microns, with automated transitions between modes. - In situ and in operando studies using accessories for temperature control, tensile loading, UV/VIS in situ spectroscopy, and dynamic sample dilution. - Customizable workspace can be modified to incorporate experimental stimulation such as magnetic fields and laser excitation. - Both Cu and Mo sources: copper in Rigaku rotating anode source and molybdenum in secondary Genix source. - Copper enables high flux investigations of both liquid and solid phase materials. - Molybdenum secondary source allows investigations of thick samples (>4mm) as well as high-Z materials and packaged samples. - Automation - Robotic sample handling for high-throughput data acquisition in solution studies - Capability for performing remote operation - BioXolver sample loading robot - Multiple sample holder options - Multisample holder for powders and gels - Multi refillable capillary holder with temperature control (-10°C to 80°C) - Thermoregulation chiller for multi refillable capillary holder - BioCUBE flow cell Assembly & cleaning pump system - Multiple stages for stimulation - Humidity stage (RH 1% to 95% at 10°C to 70°C) - Multi-purpose X-ray temperature stage (-20 to 150°C) - High temperature sample stage (-150°C to 350°C) - Integrated tensile stage (force range 0 N to 20 N with 0.001 N resolution or 0 N to 200 N with 0.01 N resolution) - Shear cell system (ambient to 350°C) with cooling unit Location Hamerschlag Hall Function X-Ray Diffraction Contact Professor Stephanie Tristram-Nagle Rates and materials - Rate type: Hourly - CMU (Internal): $35

NMR Facility Access

The NMR Facility supports high‑resolution multinuclear and multidimensional NMR studies for researchers at Carnegie Mellon University and external users. The facility houses two Bruker 500 MHz NMR spectrometers capable of advanced solution‑state NMR experiments, including direct and inverse detection using Gradient‑Assisted Spectroscopy (GRASP). Instrumentation funded in part by NSF grants CHE‑9808188, CHE‑1039870, and CHE‑1726525. The NMR Facility is primarily user‑operated, with 24/7 access for approved CMU users and permitted external researchers. Sample drop‑off service is available. Capabilities: The facility supports a broad range of multinuclear and multidimensional NMR experiments. Common applications include: Routine 1D NMR: ¹H, ¹³C, ³¹P, ¹⁹F, ¹⁵N, ²⁹Si Dynamic NMR: High‑ and low‑temperature studies; Saturation transfer; EXSY (exchange spectroscopy) 1D Multipulse Sequences: T₁ and T₂ relaxation measurements; ¹³C DEPT (45, 90, 135); Water suppression (presaturation) Multinuclear Multidimensional NMR: Homonuclear (2D): COSY (and variants), NOESY, ROESY, TOCSY; Heteronuclear (2D): HSQC, HMBC, HSQC‑TOCSY Pulsed‑Field Gradient Experiments: DOSY diffusion measurements; WATERGATE water suppression; Excitation sculpting; Gradient‑selected multidimensional experiments User‑Operated Instrument Time: $25.00/hour for CMU users; External rates available on request. Sample Drop‑Off: Sample submission available for an additional fee. Contact Professor Gil for pricing. Training: Required for all users. Weekly users are encouraged to be trained as operators for faster turnaround and reduced cost. Prerequisites: Completion of CMU laboratory safety training; A real sample ready to use during training. Training is arranged on‑demand with the director, Professor Roberto R. Gil.

Zeiss Xradia Crystal CT

This instrument can be used in two different modes: 1. Absorption Contrast Tomography (ACT): the sample is rotated in small steps around the vertical axis and absorption images are recorded for each orientation; those images are then recombined into a 3D reconstruction of the mass-density of the object. 2. Diffraction Contrast Tomography (DCT): the diffracted beams generated by the crystalline structure of the polycrystalline sample are intercepted by a planar detector and used, along with the ACT signal, to reconstruct the 3D microstructure of the sample, including the crystallographic orientations of the individual grains. In the DCT mode, the standard data acquisition mode is augmented by three advanced acquisition modes: helical phyllotaxis for cylindrical samples with high aspect ratios; helical phyllotaxis raster, for samples that are wider than the field of view, and helical phyllotaxis HART, for flat or plate-like samples. All modes allow for grain microstructures down to about 20 μm grain size to be studied in a non-destructive way, opening the path to in-situ observations. Specifications: - X-ray Tube: the x-ray source is a spot stabilized, sealed transmission x-ray tube with a voltage range of 30-160 kV and a maximum output of 10 W; set of 13 filters to tune the beam based on sample size and density. - Detector: the detector is a high speed large array CMOS flat panel detector with 3,072 x 1,944 pixels, providing a single field of view size of 144 mm (diameter) by 93 mm (height), with a maximum height of 165 mm. - System stability: granite base vibrational isolation; thermal environment stabilization; low noise detector - Sample stage: up to 25 kg sample mass capacity - ACT resolution: Spatial resolution: 0.95 μm; achievable reconstruction voxel size at working distance: 0.5 μm at 0.5 mm; 0.8 μm at 2.5 mm; 2.5 μm at 12.5 mm; 4.0 μm at 25 mm; 12.1 μm at 100 mm - DCT resolution: grain angular resolution 0.1°; grain detectability 20 μm; - Acquisition Software: Zeiss Scout-and-scan control system - Reconstructions ACT: Zeiss XMReconstructor - Reconstructions DCT: XNovo Technology GrainMapper3D (allcrystal symmetries available) - Visualizations: ORS Dragonfly Pro for 3D visualization and analysis

FEI Tecnai F20 TEM/STEM

The 200kV FEI Tecnai F20 Super-Twin is designed to produce optimum high-resolution performance in both TEM and STEM. This microscope features a 2048x2048 CCD camera positioned after the Gatan Imaging Filter (GIF) that can be used for both dedicated spectroscopic analysis and energy-filtered imaging. The high Resolution Gatan Rio Camera can deliver high resolution and real time speed for imaging applications. This microscope is optimized for materials applications that require either high-resolution STEM performance (imaging and spectroscopy by Electron Energy Loss Energy and Dispersive XRAY) or correlated imaging and analytical methods (for TEM and STEM). The Tecnai F20 is equipped with a Lorentz Lens for magnetic imaging in Fresnel and Fouccault modes, and a NanoMegas Astar system for automated phase/orientation mapping of nanocrystals materials. Also available is the Gatan STEMx System, which is a powerful tool that adds 4D STEM diffraction capabilities to the Gatan in-situ Rio camera. Specifications Electron source - Flexible high tension (20, 40, 80, 120, 160, 200 kV and values in between) - Schottky field emitter with high maximum beam current (> 100 nA) - High probe current (0.5 nA or more in 1 nm probe) - Small energy spread (0.7 eV or less) • Spot drift < 1 nm/minute Imaging Everhardt Thornley SED (secondary electron detector) - TEM point resolution (.24nm) - TEM line resolution (.102nm) - Information limit (.14nm) - Extended resolution (TrueImage) Minimum focus step (.16nm) - TEM magnification range 25X-1030kx - Camera length 30-4500mm - Maximum diffraction angle STEM HAADF resolution (.19nm) - STEM magnification range Maximum tilt angle with double-tilt holder + 40° - Maximum tilt angle with tomography holder + 80° - EDS solid angle 0.13 srad Specimen stages - FEI Single Tilt Holder +40° - FEI Double Tilt Holder +30° - Tomography holder + 80° - Gatan 636-DH low background - Liquid nitrogen cooling holder -170°C/ 23°C - Magnetizing Holder: In-plane magnetic field up to 900 Gauss - Electron imaging from -300 Oe to +300 Oe - Nanofactory Holder single tilt, for electron and force nanoprobing

Microscopes: Widefields

Zeiss AxioObserver Z1 Wide-field LED-based inverted epifl. microscope Axio Observer is your stable research stand for demanding multimodal imaging of living and fixed specimens. This inverted microscope offers the latest generation of LED illumination for gentle imaging. And creates the optimal environment for a whole range of samples to deliver reliable, reproducible data. Pricing: Peak (Mon-Fri, 9AM-5PM): $40/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $30/hr Nikon TiE WideField LED-based inverted epifluorescence HCS/ area imager Combined with NIS-Elements imaging software, the Ti supports diverse image acquisition and analysis methods such as multi-dimensional time-lapse imaging to acquire temporal, spatial and spectral information of fast, dynamic live cell processes. Intelligently designed automation and further expansion of Nikon's powerful modular approach make the Ti ideal for applications such as confocal, FRET, High Content Analysis (HCS), and photobleaching/photo activation to study interaction of fluorescence protein molecules in living cells and tissues. Nikon's exclusive Perfect Focus System (PFS) is now incorporated into the nosepiece unit and allows for the simultaneous use of two separate levels for additional illuminators or detectors. The newly developed "full intensity" phase contrast unit enables acquisition of incredible phase contrast images without the use of light-attenuating phase contrast objectives Pricing: Peak (Mon-Fri, 9AM-5PM): $40/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $30/hr

ThermoFisher Helios 5 Hydra UX PFIB

Electron beam resolution - At optimum WD - 0.7nm at 1 kV - At coincident Point - 0.6 nm at 15 kV - 1.2 nm at 1 kV Electron beam parameter space - Electron beam current range: 0.8 pA to 100 nA at all accelerating voltages - Accelerating voltage range: 350 V – 30 kV - Landing energy: 20* eV – 30 keV - Maximum horizontal field width: 2.3 mm at 4 mm WD Ion Optics High-performance PFIB column with unique Inductively Coupled Plasma (ICP) source supporting four ion species with fast switching capability - Ion species (primary ion beam): Xe, Ar, O, N - Switching time <10 minutes, only software operation - Ion beam current range: 1.5 pA to 2.5 µA - Accelerating voltage range: 500 V – 30 kV - Maximum horizontal field width: 0.9 mm at beam coincidence point Xe ion beam resolution at coincident point - <20 nm at 30 kV using preferred statistical method - <10 nm at 30 kV using selective edge method Detectors - Elstar in-lens SE/BSE detector (TLD-SE, TLD-BSE) - Everhart-Thornley SE detector (ETD) - IR camera for viewing sample/column - High-performance In-Chamber Electron and Ion Detector (ICE), for secondary ions (SI) and electrons (SE) - In-Chamber Thermo Scientific Nav-Cam™️ Sample Navigation Camera - Retractable low-voltage, high-contrast directional solid-state backscatter electron detector (DBS) - Integrated beam current measurement Analytical Detectors - EDAX Octane Elite Super EDS - EDAX Velocity Ultra EBSD Stage and Sample High-precision, five-axis motorized stage with Piezo-driven XYR axis - XY range: 150 mm - Z range: 10 mm - Rotation: 360° (endless) - Tilt range: -38° to +60° - XY repeatability: 1 μm - Max sample height: Clearance 55 mm to eucentric point - Max sample weight at 0° tilt: 500 g (including sample holder) - Max sample size: 150 mm with full rotation - Compucentric rotation and tilt Chamber - E- and I- beam coincidence point at analytical WD (4 mm SEM) - Ports: 21 - Inside width: 379 mm - Integrated plasma cleaner Location Roberts Hall Function SEM

Thermo Fisher Themis 200 G3 Aberration Corrected STEM

The Themis 200 is a state of the art 80-200 kV FEG Scanning Transmission Electron Microscope designed to deliver ultimate performance in TEM and STEM modes. An incorporated Cs probe corrector provides sub-Å resolution in STEM mode. An optimized lens control system allows each and every microscope setting to be optimized, maximizing performance, while minimizing aligning and tuning. The Themis 200 is equipped with the ThermoFisher designed X-FEG; a high brightness Schottky field emission source which combines the benefits of a Schottky FEG (high total current, great stability, and long lifetime) with the brightness of a cold FEG. The system also includes ThermoFisher's proprietary Super-X EDX system. This system is a Silicon Drift Detector (SSD) based technology providing high sensitivity and speed in EDX analysis and fast EDX mapping. Additionally, the Themis is equipped with a Lorentz Lens for magnetic imaging in Fresnel and Fouccault modes. Specifications Electron source - Accelerating Voltages: 80 and 200 - X-FEG high brightness electron source - High temporal coherence - High stability and total current Imaging - TEM point resolution: 0.24nm - Cs DCOR probe corrector - STEM point resolution: 78 pm (Cs corrected) - Information limit: 0.11nm - TEM magnification range 235X-1500kx - STEM magnification range: 500x-165Mx - Camera length 28.5-3100mm Detectors - High angle angular dark field (HAADF) detector for STEM - 4 on-axis ADF/BF detectors including a 4 Quadrant ADF for differential phase contrast (DPC) imaging - Super-X EDS detector - Ceta 16M CMOS camera Specimen stages - FEI Single Tilt Holder +40° - FEI Double Tilt Holder +30° - Tomography holder Location Roberts Hall Function TEM Rates and materials - Rate type: Hourly - CMU (Internal): $90

Microscopes: Confocals

Zeiss 880 Laser Scanning This microscope system provides one-photon (1-p) confocal, photo-manipulation and spectral unmixing fluorescence technologies. Six laser lines (405, 458, 488, 514, 561 and 633 nm). Image acquisition includes multi-color, z-stack, time lapse and multi-position with hardware autofocusing, which is suitable for applications such as localization, colocalization, time-lapse, uncaging, FRET, FRAP, and ratio imaging. The instrument also has fluorescence correlation spectroscopy capabilities. Pricing: Peak (Mon-Fri, 9AM-5PM): $40/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $30/hr Andor Revolution XD Spinning Disk Microscope This system provides a range of laser-illuminated microscopy solutions, including spinning disk confocal, and total internal reflection fluorescence (TIRF) modalities, ideal for live-cell imaging and photo-manipulation. There are four laser lines (405, 488, 560, and 640 nm) and three cameras (two EMCCD and one CCD). Pricing: Peak (Mon-Fri, 9AM-5PM): $40/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $30/hr

FEI Quanta 600 FEG SEM

The Quanta 600 FEG Scanning Electron Microscope is a versatile, high-performance instrument with three modes (high vacuum, low vacuum and ESEM) to accommodate the widest range of samples of any SEM system. The Quanta SEM system is equipped with analytical systems, energy dispersive spectrometer, and electron backscatter diffraction. The Quanta 600 FEG has a large chamber, enabling the analysis and navigation of large specimens with a motorized stage (50mm, 100mm, and a motorized z-range of 150mm) Specifications Electron beam resolution - High vacuum 1.0 nm* at 30 kV (SE) 2.5 nm at 30 kV (BSE) 3.0 nm at 1 kV (SE) - High vacuum with beam deceleration option 1.0 nm at 1 kV (BD mode + BSED) 2.3 nm at 1 kV (BD mode + ICD*) 3.1 nm at 200 V (BD mode + ICD) - Low vacuum 1.4 nm at 30 kV (SE) 2.5 nm at 30 kV (BSE) 3.0 nm at 3 kV (SE) - Extended vacuum mode (ESEM) 1.4 nm at 30 kV (SE) Detectors Everhardt Thornley SED (secondary electron detector) - Large Field Low vacuum SED (LFD) - Gaseous SED (GSED) (used in ESEM mode) - High sensitivity low kV SS-BSED - IR camera for viewing sample in chamber - Gaseous BSED (BSE detector for high pressures, used in ESEM mode) - 4 quadrant solid-state BSED - vCD (low voltage high contrast detector) - Electron beam current measurement - Gaseous analytical BSED (GAD) Oxford INCA EDS System full analytical, XMAX 80mm SDD EDX detector. Oxford HKL EBSD System with high speed HKLNordlysNano camera. HYSITRON PI-85 SEM PicoIndenter. Location Materials Characterization Facility Function SEM Contact Neal Lewis Rates and materials - Rate type: Hourly - CMU (Internal): $65

Zeiss Crossbeam 550 Gallium FIB

Our new Ga FIB is a Zeiss Crossbeam 550 featuring a Gemini II SEM column and Ion-sculptor FIB column. The Gemini II SEM column is a very stable electron column that boasts high-resolution even at low voltages and high currents due to the double condenser system. The combination of electrostatic and magnetic fields in the objective lens also allows for minimal field effects at the sample. High quality images of even the toughest samples, such as magnetic materials, are possible. The Ion-sculptor FIB column can achieve fast milling at high currents while also offering high performance at low voltages. The stability and performance of the ion column make it the perfect tool for TEM lamella preparation. The system is also outfitted with a load-lock for fast sample transfer and an Oxford Omniprobe 400 micromanipulator for lift-out. There are no analytical detectors. Resolution - 1.4 nm at 1 kV (SEM) - 0.6 nm at 30 kV (STEM) - 3 nm at 30 kV (FIB) Accelerating Voltage - 0.02 to 30 kV (SEM) - 0.5 to 30 kV (FIB) Probe Current - 10 pA to 100 nA (SEM) - 1 pA to 100 nA (FIB) Detectors - SESI (Secondary electron secondary ion) - Inlens SE (in column SE detector) - Inlens EsB (in column BSE detector with filtering grid) - aSTEM4 (STEM detector with BF, DF, ODF, ADF, and HAADF) Gas Injection System - Platinum - Carbon Location Hamerschlag Hall Function SEM

Shared Department Instrumentation

In addition to core facilities, the Department of Chemistry supports a broad range of instruments located within research groups and shared with the department. These tools enhance both synthetic and physical chemistry research capabilities. Shared instruments include: - Chemical Ionization Mass Spectrometer and High Resolution Time of Flight Aerosol Mass Spectrometer (Donahue group) - X-band IBM ER-300 EPR spectrophotometer with both X-band bridge and liquid nitrogen and liquid helium low-temperature capabilities (Hendrich group) - Surface Plasmon Resonance and Calorimetry (Armitage group) - DNA/RNA solid phase synthesizer (Das group) - Photoreactor (Bernhard group) - Solar cell fabrication/testing station; Atomic Force Microscopy; SAXS for Nanostructured Characterization (Kowalewski group)

NT-MDT NTegra II SPM

The Ntegra II is a highly modular scanning probe microscope (SPM) that boasts many imaging and point measurement modes. It is a great tool for anything from topography measurements to custom-environment, tailored experiments. Housed in a temperature and vibration stabilized enclosure, the microscope can easily produce sub-nanometer precision. Ntegra II Features: - Maximum scan area of 100um x 100um x 10um (X Y Z) - Signal breakout box (output/input any electrical signal created/used by the microscope) - Heating/cooling stage -30C to +120C - Sealed liquid cell (image in aqueous environment) - Scanning probe (large samples or liquid environment) Ntegra II Analysis Modes: - Sample topography imaging - Tapping Semi-Contact Atomic Force Microscopy - Tapping Non-Contact Atomic Force Microscopy - Contact Atomic Force Microscopy - Mechanical property imaging - HybriD Mode (mechanical property imaging) - Force-Distance Curves - Lateral Force Microscopy - Phase Contrast Microscopy - Magnetic Force Microscopy - Electrostatic Force Microscopy - Kelvin Probe Microscopy (Scanning Kelvin Microscopy) - Scanning Capacitance Microscopy - Piezoresponse Microscopy Location Roberts Hall Function Scanning Probe Microscopy Rates and materials - Rate type: Hourly - CMU (Internal): $35

Materials Characterization Facility access

The CMU Materials Characterization Facility is open to researchers across Carnegie Mellon’s campus, as well as external users from corporate, government, and university affiliates. More than 220 individual researchers take advantage of the facility each year. Once a member, all researchers may benefit from: Staff support and training; Networking opportunities with students, postdocs, faculty, and staff; Access to state-of-the-art instrumentation. The Materials Characterization Facility is open 24 hours to researchers and is staffed Monday - Friday from 8 a.m. - 5 p.m. The Materials Characterization Facility welcomes external users from corporate, government, university, and nonprofit affiliates.

User-Operated Instrument Time

Invoicing occurs quarterly. Hourly charges are based on the logon time. Rates are subject to change without prior notice. You must provide either: A CMU Oracle account number OR For Non-CMU Users: A hard copy of the PO number and outside billing address. MS and photon charges are based on the reserved calendar time or the logon time, which ever is greater. Laboratory assistance in MI 551 is provided by CMA staff at a rate of $50/hour. MS and Photon training and Non-CMA training is provided at $100 per user. MS training for industry is provided at $1250 per user.

Nanofab Equipment Access

The Nanofab provides up to 100 processing tools to the community, all of which are supported through user fees, with new acquisitions supplemented by internal university funds and research grants from faculty. Researchers using the Nanofab can rely on six technical staff members to guide them by providing hands-on experience, helping them choose the best tools and processes for their research. Staff members also assist with tool training, process development, tool maintenance, and tool repair, providing expertise in lithography, film deposition, etching, metrology, annealing, and more.

Horiba LabRAM Soleil Raman

The Horiba LabRAM Soleil is a high performance Raman microscope for material separation and characterization. This instrument is capable of ultra-fast imaging and analysis automation. Our microscope is equipped with four lasers and an ultra-low frequency filter to suit a wide variety of Raman spectroscopy needs. Specifications Full Collegial Support program - Reference Horiba Raman experts for advanced, material-specific Raman questions Nikon optical microscope base - Fast, motorized X,Y stage - Three objective lenses - 5X, 50X, and 100X - With motorized objective focus - Large specimen capability Four lasers - 405nm (30mW), 532nm (100mW), 638nm (30mW), and 785nm (100mW) - 532nm ultra-low frequency edge filter (Measuring low frequency Raman shifts up to 10cm-1) Confocal scanning laser mirrors - Spatial resolution up to ~300nm Three gratings - Internal spectrometer measurement standard (precise and accurate wavenumber changes) Polarized Raman (crystallography measurements) Location Roberts Hall Function Raman Rates and materials - Rate type: Hourly - CMU (Internal): $35

Center for Molecular Analysis (CMA) Instrument Use and Analysis

The Center for Molecular Analysis (CMA) features modern high-performance analytical instruments for use by researchers both at CMU and external to CMU such as at the University of Pittsburgh and industry. The CMA instruments are available to trained user-operators 24 hours/day and sample drop-off is also offered for mass spectrometry. In addition to the analytical instrumentation, the CMA provides collaborations, analytical assistance, and training. Professor Mark Bier offers expertise and instrumentation for advanced ultra-high m/z (heavy ion MS) analysis.

Zeiss Axio Imager Z2 Vario Optical Microscopy

The Zeiss Axio Imager Z2 Vario is a high performance, multi-function optical microscope. The precise motorized microscope stage is equipped to analyze very large samples up to approximately 40cm X 40cm X 12cm (L W H). There are three sample illumination modes (including dark field and PLM), six objective lenses, and a color camera with resolution that reaches the limit of optical microscopy. Specifications: Imaging (Illumination) Modes: - Bright Field - Dark Field - Polarized Light (PLM) Hardware / Software: - Laser autofocus - Zeiss Axiocam 820 high resolution color camera - Motorized X, Y, Z stage - Zeiss Zen Core - 5X, 5X, 10X, 20X, 50X, and 100X objective lens - Tube multipliers lens up to 2.6X Techniques available: - Image stitching (Tiling) for large view field - Z stacking - Extinction measurements - Image correlation for overlaying multiple images (Raman, SEM, etc.) Example uses: - Metallography corrosion studies - Thin film uniformity - Fracture surfaces - Mineralogy birefringent studies - Inclusion analysis in metals - Grain imaging Location Roberts Hall Function Optical Microscopy Contact Andrew Nickischer

Zeiss Sigma 560 VP SEM

The Sigma 560 VP SEM is equipped with Zeiss’ in situ solution. The in situ solution features a Deben stage capable of applying both load and heat (specifications below) and Zeiss’ In Situ Lab software that integrates control of the microscope, Deben stage, and Oxford analytical detectors. Electron Beam - Accelerating Voltage: 0.02 kV to 30 kV - Probe Current: 3 pA to 100nA Resolution - 7 nm at 15 kV - 2 nm at 1 kV - 5 nm at 500 V - 5 nm at 30 kV (VP Mode) Detectors - SE Everhart-Thornley Detector - In-lens SE Detector - VPSE Detector - KARMEN high temperature BSE detector Stage - XY range: 130 mm - Z range: 50 mm - Tilt range: -4° to 70° - Rotation: 360° continuous Deben Stage - Force: 5000 N - Temperature Range: RT - 800°C - Flat sample jaws and 70° tilt jaws for EBSD Analytical Detectors - Oxford UltimMax 100mm 2 EDS Detector - Oxford Symmetry S3 EBSD Camera Location Hamerschlag Hall Function SEM Rates and materials - Rate type: Hourly - CMU (Internal): $65

Malvern Panalytical Empyrean XRD

The Empyrean has focusing optics and parallel beam optics. It is used for powder/bulk XRD analysis, thin film analysis, pole figures, residual stress measurements, reflectivity, rocking curves, microdiffraction, and in situ high temperature work. Capabilities - Pole figures - Residual stress - X-ray reflectivity - Rocking curves - Microdiffraction - High temperature (1600°C in air, vacuum, and inert environments) Incident Beam - Fixed slits - X-ray mirror (with optical microbeam optics) - Polycapillary lens Diffracted Beam - Parallel plate collimator (receiving slit and graphite monochromator optional) - Fixed Slits - Proportional Detector - 1Der Detector Hot stages - Anton Paar 16N is a strip heater that can go to 1600°C in air, vacuum, and inert environments X-ray source - Copper - Molybdenum Location Hamerschlag Hall Function X-Ray Diffraction Contact Betsy Clark Rates and materials - Rate type: Hourly - CMU (Internal): $35

Intellicyt / Accuri High Throughput Flow Cytometer

The Intellicyt front end allows rapid sampling of 96-well plates and feed of these samples to the attached Accuri C6 flow analyzer to produce high-throughput single cell analysis data of up to two fluorescence parameters. The Accuri is equipped with two excitation lasers, 488 and 640 nm. Pricing: Peak (Mon-Fri, 9AM-5PM): $85/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $64/hr

Zeiss Axio Imager M2m Optical Microscopy

Specifications: Imaging (Illumination) Modes: - Bright Field (reflected and transmitted light) - Dark Field - Polarized Light (PLM) (reflected and transmitted light) - Differential Interference Contrast (DIC) Hardware / Software: - Zeiss Axiocam 506 high resolution color camera - Motorized X, Y, Z stage - Zeiss Zen Core - Zeiss Zen Pro - 5X, 10X, 20X, 50X, and 100X objective lens Techniques available: - Image stitching (Tiling) for large view field - Z stacking - Contrast for optically transparent samples - Extinction measurements - Image correlation for overlaying multiple images (Raman, SEM, etc.) Example uses: - Imperfections in thin films - Crack propagation in metals - Mineralogy birefringent studies - Visualize biofilm formation - Scan large sections of composite materials - Inclusion analysis in metals - Grain imaging Location Roberts Hall Function Optical Microscopy

FTIR Spectrometry

The PerkinElmer Fourier Transform Infrared (FTIR) spectrometer provides quick chemical and molecular characterization of a wide range of materials. Equipped with an Attenuated Total Reflectance (ATR) accessory, the system enables direct analysis of solids, powders, films, and liquids with minimal sample preparation. FTIR spectroscopy can be used to identify chemical functional groups, characterize polymers and organic materials, and compare unknown samples with reference spectra. Specifications: - Optimal Scan Range - (7800 - 515)cm-1 - Detector - Mid-IR TGS Location Roberts Hall Function Optical Microscopy Contact Andrew Nickischer Rates and materials - Rate type: Hourly - CMU (Internal): $15

Tescan Mira 3 FEG SEM

Location Roberts Hall Function SEM Contact Neal Lewis Rates and materials - Rate type: Hourly - CMU (Internal): $65 Specifications Resolution 1.2 nm at 30 kV; 2.3 nm at 3 kV. Detectors - SE Everhart Thornley Detector - Scintillator Backscatter Detector - Scanning Transmission Electron Microscopy (STEM) Detector - Oxford X-ACT EDS Detector Stage - X,Y = 80,60 mm - Z = 47 mm; 54 mm clearance with rotation stage / 81 mm without - T = - 80° to + 80° - R = 360° continuous - Repeatability: <1 μm (x and y) - Tilt-eucentric at 10 mm mounting height for all working distances - X and Y movements are in the tilt plane

CNAST and Mellon College of Science Shared Resources & Equipment Access

These CNAST or Mellon College of Science resources are available for general use by CNAST members. ABI 2720 PCR Thermal Cycler Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider ABI 310 Genetic Analyzer Capillary Electrophoresis System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider ABI 3130xl Genetic Analyzer Capillary Electrophoresis System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider ABI ViiA7 qPCR Machine Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Access to Modified DNA/RNA Sequences - For DNA up to 35 mers and RNA up to 30 mers - For incorporating modifications for which commercial specialty phosphoramidites are available (via GlenResearch) Das Lab, MI 742 Contact: Subha Das Agilent TapeStation - For rapid gel electrophoresis and automated analysis of RNA and DNA abundance, size, and integrity McManus Lab, MI 255 Contact: Joel McManus AKTA Explorerer FPLC Liquid-phase Chromatography System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Analytical and Semiprep HPLC Achim Lab, MI 835/839 Contact: Catalina Achim ASI MS-2000 Programmable Translation Stage Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Beaglehole Variable-Angle Ellopsometry System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Beckman IC100 Murphy Lab Automation Suite, MBIC 1st floor Contact: Robert Murphy Beckman-Coulter P-ACE MDQ Automated Capillary Electrophoresis Systems - With UV, two-color LIF detection and photodiode array detection Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Biacore Surface Plasmon Resonance Instrument Das Lab, MI 742 Contact: Subha Das Bio-rad Gel Dryers - Model 583 Das Lab, MI 742 Contact: Subha Das Bio-Rad Protean Llxi Slab Gel Electrophoresis System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Bruker Nanoscope V MultiMode AFM System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Cary 300Bio UV-Vis Spectrophotometer - With temperature control Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Cary Eclipse Fluorescence Spectometer - With stopped-flow accessory, peltier multi-cell holder, and temperature control Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Cell Analyzer - 88/640 lasers with 96-well plate sipper attachment Intellicyte/Accuri C6 Cytometry Center, MBIC 1st floor Contact: Yehuda Creeger Cephied SmartCyclyer PCR workstation - With 16 sample chambers and 4 channel optical detection Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Circular Dichroism Center for Molecular Analysis, MI 555 Contact: Mark Bier Coherent Optics QE Pro High-Performance Spectrometer Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Differential Scanning Calorimetry Evilevitch Lab, WH 6409 Contact: Alex Evilevitch Eppendorf 5415C Ultracentrifuge Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Eppendorf 5810R Ultracentrifuge Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Fluorescence Correlation Spectrometer - Zeiss Confocor 3 Unit Microscopy Facility, MBIC 2nd Floor Contact: Haibing Teng Fluorescence Spectrometers - Cary Bio, Equipped for melting curve analysis (2) - Photon Technology Inc Armitage Lab, MI 726 Contact: Bruce Armitage Fluorescent Activated Cell Sorter - FACSVantage, 4 lasers (405, 488, 532, 640) Cytometry Center, MBIC 1st floor Contact: Yehuda Creeger Forte Bio Red Evanescent Surface Sensor Washburn Lab, MI 814 Contact: Newell Washburn Gel Electrophoresis Equipment - For agarose and polyacrylamide gels - including large plates/gels – for gels 20cmx35cm - Reserved for use with nucleic acids (no proteins) Das Lab, MI 742 Contact: Subha Das Gel Filtration Chromatography Bruchez Lab Coldroom, MI 755 Contact: Marcel Bruchez Gel/Culture Plate Scanner - Typhoon 9700 Location TBD (2nd floor currently) Contact: Marcel Bruchez Isothermal Titration Calorimetry Rule Lab, MI 246 Contact: Gordon Rule JASCO J-810 Circular Dichroism Spectrometer Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Jobin-Yvon Fluorolog-3 Florescence Spectrometer - With TIRF accessory Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider KSV 5000 Langmuir-Blodgett Trough - With dipping accessory, Wilhelmy plate, and surface potential accessory Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Labsmith Microflluidics Toolkit - Programmable DC power supply and chip prototypes Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Malvern Zatasizer Nano Dynamic Light Scattering System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Mass Spectrometer - Q-TOF-ESI/APCI/Nanospray - LCQ-ESI/APCI Ion Trap - MALDI Center for Molecular Analysis, MI 555 Contact: Mark Bier Mermade 4 DNA/RNA Synthesizer (Bioautomation) Das Lab, MI 742 Contact: Subha Das Metamorph Imaging Software Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Nanodrop - Scanning UV-vis Spectrophotometer - For spectra with small sample (2-3 μL) volumes Das Lab, MI 742 & Shared Chemical Engineering Lab, DH 2203 Contact: Subha Das & Jim Schneider Nicolet Magna-IR 560 IR Spectrophotometer - With MCT and DTGS detection Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Nikon TE2000U Inverted Microscope - With high-resolution CCD camera (Photometrics Quatrum EM) and integrated laser system with interlocks Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider NMR Spectrometers Pittsburgh NMR Center for Biomedical Research, MI 1st Floor Apply To Use Facilities Ocean Optics QE Pro High-Performance Spectrometer Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Perkin Elmer Spectrum CT Imaging System & Surgical Suite - IVIS/CT Small animal fluorescent/luminescent/CT imaging instrument MI Vivarium Point-Scanning Spectral Confocal Microscopes - Zeiss 510 Meta 2x Shared Imaging Facility, MBIC 2nd floor Contact: Haibing Teng Potentiostat for Electrochemistry Measurements Achim Lab, MI 835/839 Contact: Catalina Achim Preparative Ultracentrifuge MBIC Common Equipment Rm, 2nd floor Contact: Haibing Teng Spectral Fluorescence Plate Reader - Tecan Safire 2 MBIC, 2nd floor Contact: Haibing Teng Spectral Fluorescence/Luminescence Plate Reader with Anisotropy - Tecan M1000 Bruchez Lab, MI 755 Contact: Marcel Bruchez SpectraMax M2 UV-Vis Fluorescence Microtiter Plate Reader System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Spinning Disk Confocal Microscope with Live-Cell Apparatus Shared Imaging Facility, MBIC 2nd floor Contact: Haibing Teng Stopped flow UV Vis Achim Lab, MI 835/839 Contact: Catalina Achim Synergy H1 Hybrid Plate Reader System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Teledyne Isco Comniflash Rf 200i Flash Chromatography System Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Tokai Hit Transparent Thermoplate Stage Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider UV Vis Spectrometers - Cary 200 - Cary 50 - Cary 300, Equipped for melting curve analysis (2) Armitage Lab, MI 726 Contact: Bruce Armitage UVP Bio-DocIt Transilluminator - With CCD Image Capture Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Waters Alliance 2690 Analytic HPLC System - With heated column, PDA, fluorescence, and DLS detection Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider Waters Delta 600 Semi-prep HPLC System - With PDA detection and fraction collector Shared Chemical Engineering Lab, DH 2203 Contact: Jim Schneider

Tecan Spark

Pricing: Peak (Mon-Fri, 9AM-5PM): $33/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $24/hr

Panalytical X’Pert Pro MRD X-Ray Diffractometer

Capabilities - Pole figures - Residual stress - X-ray reflectivity - Rocking curves - Reciprocal space maps Incident Beam - Polycapillary Lens - X-ray Mirror - Hybrid 4-bounce monochromator Diffracted Beam - Parallel plate collimator (receiving slit and graphite monochromator optional) - Triple Axis/Rocking Curve - Proportional Detector X-ray source - Copper - Cobalt (pole figures and residual stress only) Location Hamerschlag Hall Function X-Ray Diffraction Contact Betsy Clark Rates and materials - Rate type: Hourly - CMU (Internal): $35

NT-MDT Solver NEXT SPM

Solver NEXT analysis modes - Tapping and Contact AFM - Lateral Force Microscopy - Phase Contrast Microscopy - Magnetic Force Microscopy - Electrostatic Force Microscopy - Kelvin Probe Microscopy - Scanning Capacitance Microscopy - Piezoresponse Microscopy - Scanning Tunneling Microscopy Location Roberts Hall Function Scanning Probe Microscopy Contact Andrew Nickischer Rates and materials - Rate type: Hourly - CMU (Internal): $35

IMARIS PRO

Pricing: Peak (Mon-Fri, 9AM-5PM): $47/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $35/hr

Quant Studio5 qPCR

Pricing: Peak (Mon-Fri, 9AM-5PM): $17/hr; Off Peak: (Mon-Fri, 5PM-9AM; Weekends All Day): $13/hr

IDeATe Equipment Lending

The IDeATe Lending Office is a vital Carnegie Mellon University resource that boasts an extensive collection of high- and low-tech equipment for the support of academic and campus endeavors. Equipment in the collection comprises the following main categories: photo and video, lighting and projection, audio, computing, virtual reality, soft technologies, shop and tools, and cables and accessories. The entire inventory of the IDeATe Lending collection can either be searched on the Carnegie Mellon Libraries’ catalog or through this direct link. Items in this collection are available for use by Carnegie Mellon University students, faculty, and staff at the main Pittsburgh campus. In order to borrow equipment, users must present a valid Carnegie Mellon ID card. Borrowing for off-campus use in or around Pittsburgh is limited to university-sanctioned events. The IDeATe Lending Office is located in the basement of Hunt Library directly across from the elevator, in room A29. Current hours can be viewed here. Borrowing Period The normal borrowing period during the semester is three days, with a due time of 6 p.m. on the third day. For example, equipment borrowed anytime on a Monday would be due back that Thursday by 6 p.m. Due dates will skip over university holidays, with the next open date assigned as the date due. Please note that beginning in Fall 2026, due dates will no longer skip weekends; items borrowed on a Wednesday or Thursday are now due on the following Saturday or Sunday, respectively. Equipment Renewals Beginning in Fall 2026, there will no longer be renewals for equipment borrowed from the IDeATe Lending Collection. This decision was made to allow greater access to resources for collection users. Borrowing Responsibilities Borrowers must present a valid Carnegie Mellon ID at the time of checking out equipment. All patrons are required to be aware of and adhere to the IDeATe Lending Collection Circulation Guidelines.

Center for Advanced Biological Imaging Solutions (CABIS)

The Center for Advanced Biological Imaging Solutions provides access to instruments for performing a variety of advanced fluorescence microscopy techniques and flow cytometry. In the shared microscopy facility, there are state-of-the-art confocal microscopes, providing one-photon, two-photon confocal, fluorescence correlation spectroscopy (FCS), TIRF, photo-manipulation (activation/switching, ablation, FRAP), Spectra unmixing, and UV uncaging. The center also provides flow cytometry services for cell analysis.

Use Our Instruments

Several instruments are available to use for your research needs.

User-Operated Analytical Instrument Time (Center for Molecular Analysis)

The CMA instruments are available to trained user-operators 24 hours/day and sample drop-off is also offered for mass spectrometry. In addition to the analytical instrumentation, the CMA provides collaborations, analytical assistance, and training. User‑Operated Instrument Time: - Invoicing occurs quarterly. - Hourly charges are based on the logon time. - Rates are subject to change without prior notice. - MS and photon charges are based on the reserved calendar time or the logon time, which ever is greater. - Laboratory assistance in MI 551 is provided by CMA staff at a rate of $50/hour.

Photon Spectroscopy (FTIR-NIR Spectrometer (Mattson ATI Affinity 60AR), UV-VIS-NIR Spectrometer (Perkin-Elmer Lambda 900), CD (JASCO 715))

Photon Spectroscopy FTIR-NIR Spectrometer (Mattson ATI Affinity 60AR), UV-VIS-NIR Spectrometer (Perkin-Elmer Lambda 900), CD (JASCO 715) Service CMU User Academic User (non-CMU) Industry User User Operated: $20.00/hour, $75.00/hour Billed by the hour, $200.00/hour CMU — Users will be charged for start-up training at $50/hour. #New non-CMU users are charged for the first hour startup help. Sample drop-off is not available for these instruments.

AI Science Foundry

Carnegie Mellon University’s AI Science Foundry harnesses the power of autonomous, AI-enabled laboratories to accelerate the innovation-to-impact timeline from years to months. The AI Science Foundry enables AI-guided autonomous experimentation using the nation’s largest collection of co-located research tools for hard materials, chemistry, and biology across two facilities. Researchers using the AI Science Foundry have access to sophisticated instrumentation that enable them to conduct scientific inquiries that previously exceeded their capabilities. AI agents design and orchestrate experiments, drawing on any discipline or any multi-disciplinary domain by consulting published literature, health records, images, and the Foundry’s own expanding knowledge base. AI agents optimize experiments and comb vast repositories of data that no human can totally comprehend. As they analyze data, they perceive correlations and causality that scientists might not recognize.

Liquid Chromatography (Thermo Scientific Vanquish Flex Binary UHPLC; Thermo Scientific EASY-nLC 1200 Nanoflow Liquid Chromatograph)

Thermo Scientific Vanquish Flex Binary UHPLC; Thermo Scientific EASY-nLC 1200 Nanoflow Liquid Chromatograph MS Service CMU User Academic User (non-CMU) Industry User User Operated: $30.00/hour, $100.00/hour Billed by the hour, $180.00/hour Billed by the hour CMU — Users will be charged for start-up training at $50/hour. #New non-CMU users are charged for the first hour startup help.

Flow Cytometry Core Facility Access

The Flow Core Currently has a BD FacsVantage equipped with 5 lasers and 8 detectors as well as an Accuri Flow Cytometer Analyzer Connected to an Intellicyt Hypercyt robotic system cappable of running a 96 well plate through the Accuri in just 5 minutes. Users are welcome to run experiments or sorts that comply with the posted guidelines. The FacsVantage can sort rare cell types at a speed of about 20000 cells per second. The 5 laser colors are 405, 488, 532, 635 and 730.There are 2 fluorescent microscopes on site to assist with your research.

Bruker Ultraflexetreme MALDI TOF/TOF

MS Service CMU User Academic User (non-CMU) Industry User User Operated: $30.00/hour, $45.00/hour, $180.00/hour* Sample Drop-Off†: $45.00/sample, $75.00/sample, $250.00/sample (1 week turn-around; rate doubles within 48hrs)

Use Our Instruments

Several instruments are available to use for your research needs.

CEAVerified

Government & National Laboratories · 11–50 employees · France

2 listed under this category

Materials platforms

Materials. Includes: Nanocharacterization platform; Laser platform; Upstream technology platform; Platform for access to the large-scale heavy-ion accelerator (GANIL).

Supercomputing - Research and Technology Computing Center (CCRT)

Learn about research equipment available to companies in the area of high performance computing. CCRT The Research and Technology Computing Center (CCRT) is the only supercomputing center available to industry for research in France, and one of the few in Europe. Located in the CEA’s Very Large Computing Center (TGCC) in Bruyères-le-Châtel near Paris, the CCRT offers its partners the computing power necessary for numerical simulations, and the skills of the CEA's staff in all related scientific disciplines, including computing center architecture, storage expertise, machine room engineering, image treatment, modelling of complex physical phenomena, and software development. The prototype for all subsequent industrial partnerships, the CCRT has been operating since 2003 and has continually demonstrated its ability to respond to the needs of industry in an secure environment conducive to growth. Industrial partners: AREVA, EADS/Astrium, EDF, Ineris, Snecma, Techspace Aero, Turbomeca, Valéo and since 2013, L’Oréal and Thalès, are partners of CCRT, in addition to four CEA research clusters (material sciences, nuclear energy, military applications, and life sciences). The presence of these major companies confirms the role of numerical simulation in industry for accelerating innovation and productivity. The CCRT’s Airain computer (200 Tflops) © Cadam/CEA Numerical simulation of aerodynamic phenomena in the combustion chamber of an airplane engine. © Snecma

Center for Functional Nanomaterials BrookhavenVerified

Government & National Laboratories · 51–200 employees · United States

9 listed under this category

NSLS-II Beam Time & User Research Access

From batteries and microelectronics to drug design and cultural heritage, scientists advance our understanding of many materials every day to solve the world’s greatest challenges. However, today's problems are so complex that they require scientists to study materials with highly specialized tools and expertise that are not readily available at most institutions. That’s where the National Synchrotron Light Source II (NSLS-II) comes in. As one of the newest, most advanced synchrotron facilities in the world, NSLS-II enables its growing research community to study materials with nanoscale resolution and exquisite sensitivity by providing cutting-edge capabilities. The facility’s state-of-the-art, medium-energy electron storage ring (3 billion electron-volts) generates ultrabright, highly stable beams of light, ranging from infrared to hard x-rays, to run 30 experimental stations, or beamlines. Each of our beamlines offers unique research tools to reveal the electronic, chemical, and atomic structure of materials. Together with visiting researchers (users) and partners from all around the world, interdisciplinary teams at NSLS-II explore materials, focus on the most important challenges in science and technology. Learn more about this U.S. Department of Energy (DOE) Office of Science User Facility. Next deadline for proposals and beam time requests: January 31, 2027 at 11:59 p.m. (ET). Submission Details

Scientific Computing and Data Facilities (SCDF)

Scientific Computing and Data Facilities (SCDF) at Brookhaven Lab began in 1997 when the Relativistic Heavy Ion Collider (RHIC) and ATLAS Computing Facility was established. Then called RACF, the full-service scientific computing facility has since supported some of the most notable physics experiments, including Broad RAnge Hadron Magnetic Spectrometers (BRAHMS), Pioneering High Energy Nuclear Interaction eXperiment (PHENIX), PHOBOS Collaboration, and Solenoidal Tracker at RHIC (STAR), by providing dedicated data processing, storage, and analysis resources for these diverse, expansive experiments with general computing capabilities and support for users. Today, this history of providing useful, resilient, and large-scale computational science, data management, and analysis infrastructure has grown, and the SCDF (formerly SDCC) has evolved to support additional facilities and experiments. These include the National Synchrotron Light Source II (NSLS-II) and Center for Functional Nanomaterials (CFN) at Brookhaven Lab, as well as other DOE Office of Science User Facilities; the ATLAS experiment at CERN's Large Hadron Collider in Europe; and Belle-II at KEK in Japan and DESY in Germany. SCDF also is planning for its role in future experiments with the sPHENIX, Deep Underground Neutrino Experiment, and Electron-Ion Collider. For users, SCDF offers a single-point facility with high-throughput, high-performance, and data-intensive computing along with data management, storage, analysis, and preservation capabilities that support scientific programs in domains spanning physics, biology, climate, and energy. SCDF also serves as the core for Brookhaven Lab's institutional computing needs, connecting scientists and researchers at home and abroad.

Materials Synthesis and Characterization Facility

The Materials Synthesis and Characterization Facility includes laboratories for producing nanostructured materials and characterizing their basic structural, chemical and optical properties. The facility staff has significant experience in solution-phase chemistry of nanocrystal/nanowire materials, inorganic synthesis by chemical vapor deposition, physical vapor deposition, and atomic layer deposition. The staff includes experts in techniques of nanoscale fabrication by self-assembly. The facility also supports infrastructure and expertise in solution-based processing of organic thin films, including tools for spin-casting, thermal processing, and UV/ozone treatment. Analytical tools include a broad range of capabilities for structural, electrochemical, spectroscopic and thermal characterization of materials. - Synthesis of nanostructures by chemical vapor deposition and solution-based methods Solution-based synthesis of a variety of soft, biological, hybrid, and inorganic nano-materials and functionalization routes for surfaces and nano-objects - Self-assembly methods for polymers - Solution-based processing of organic thin films by spin-casting and dip coating - Preparation of DNA- and protein-based nanostructures Gel-based DNA purification, conventional and real-time PCR for DNA amplification - Structural and functional probing of nanostructures using x-ray scattering, optical, and scanning probes methods - Electrical characterization under various temperature, magnetic field, and illumination conditions

Laboratory for BioMolecular Structure

The Laboratory for BioMolecular Structure (LBMS) is a state-of-the-art center for life science imaging with the mission to increase our fundamental understanding about the building blocks of all living organisms and their function. By fulling its mission, LBMS fosters faster developments in biotechnology, drug development, and medical technologies to meet the nation’s needs in biofuels and healthcare. LBMS offers researchers from universities and industry free access to state-of-the-art cryo-electron microscopes and laboratory equipment to investigate life in its many forms on a molecular level.

Facilities Available to Researchers

Scientists from academia, government labs, and commercial institutions can choose from a wide range of research techniques and equipment. Facilities available to qualified researchers include the National Synchrotron Light Source, the Center for Functional Nanomaterials, the Relativistic Heavy Ion Collider, and the NASA Space Radiation Facility.

Advanced Computing Lab

The ACL is a focal point and collaborative environment at Brookhaven Lab for research and development of architectures and systems, as well as for siting and enabling advanced computing testbeds. It consists of state-of-the-art equipment capable of facilitating R&D on computing technologies at different development and maturity stages, from materials to devices to subsystems to early full-system prototypes. - High-resolution, accurate static and dynamic instrumentation for performance (time), power, and reliability can be included on specialized workbenches. - The ACL machine room space is properly designed for optimal operation and safe access to experimental testbeds. - Network connectivity for external users can be provided as required. - The ACL can accomodate office space for technology providers and external collaborators.

NASA Space Radiation Facility

The NASA Space Radiation Laboratory (NSRL) is a NASA-funded beam line and associated user-support building designed to carry out research on the effects of space radiation on biological systems, primarily, as well as on electronics and materials. NSRL delivers protons and heavy ions at space-relevant energies, serving a mostly NASA-supported community of researchers, with a small but growing group of non-NASA users testing electronics and investigating radiation therapy. NASA users who pass review by both NASA and Brookhaven Lab are granted beam time paid for by NASA. All others must pay on a full cost-recovery basis.

Northeast Solar Energy Research Center (NSERC)

The Northeast Solar Energy Research Center (NSERC), located on the Brookhaven Lab campus, serves as a solar energy research and test facility for the solar industry. NSERC includes laboratories for standardized testing in accordance with industry standards, along with a solar PV research array for field testing existing or innovative new technologies under actual northeastern weather conditions. NSERC includes access to unique high-resolution data sets from the 32MW Long Island Solar Farm located at Brookhaven.

Laser Application Laboratory

The Instrumentation Department’s Laser Application Laboratory features cutting-edge laser systems with a range of wavelengths (infrared to vacuum ultraviolet), pulse durations (femtosecond to microsecond), pulse energies (nanojoule to nearly one joule), and operational modes (single photons to multiphotons per pulse). These systems are routinely used for large-scale particle physics experiments.

‹…