Nanoindentation and thermal/electrical/optical testing.
Showing all 154 providers

Equipment & Instrumentation Manufacturers · 11–50 employees · United States
3 listed under this category
Manipulation and Biasing of Low Dimensional Materials
Probe targeted regions of low-dimensional materials to correlate electrical behavior with nanoscale structural evolution. With Hummingbird you can: Precisely probe and bias targeted regions of low-dimensional materials using the Hummingbird Scientific biasing manipulator sample holders.
2D materials-based electronic devices
Correlate electrical transport with nanoscale structural evolution in operating 2D materials-based devices. With Hummingbird you can: Perform operando testing and imaging of 2D materials-based devices using Hummingbird Scientific electrical biasing sample holders.
2D material at high temperatures
Observe phase transformations, structural evolution, and thermal stability of 2D materials at elevated temperatures. With Hummingbird you can: Observe 2D materials behavior at elevated temperatures using Hummingbird Scientific MEMS heating + biasing sample holders.

Contract & Professional Service Providers · 1–10 employees · United States
1 listed under this category
Testing
- 200 mm wafer-level and chip-level probe in-house - Electrical and physical test

Equipment & Instrumentation Manufacturers · 51–200 employees · Germany
1 listed under this category
Anisotropy imaging
abberior has developed a fully motorized upgrade for polarization anisotropy measurements with our INFINITY line. It is entirely compatible with all STED imaging modes. To this end, every beam path – excitation, STED, as well as the detection beam path – is equipped with motorized polarization optics. Full software integration and a dedicated calibration procedure ensure that the user can select arbitrary polarization conditions for each beam of her INFINITY STED microscope.

Contract & Professional Service Providers · 1–10 employees · France
1 listed under this category
Inverse Gas Chromatography (IGC) for Transition and Crystallinity Measurement
Since 1969, Guillet and his co-workers have initiated the use of IGC for the measurement of the glassy transition temperature of a polymer deposited on a solid support [Lavoie and Guillet (1969)]. Other works have been done on the influence of the tacticity of a PMMA deposited on an alumina on the Tg by Braun and Guillet (1975), Hamieh and al (1988). Hamdi and al (2002) have also studied the influence of the impregnation ratio on the Tg of a PMMA deposited on pyrogenic silica. Finally, a review on the subject was done by Nastasovic and Onjia (2008). The method generally applied for the study of the polymer transition consists in representing the variation of the retention volume Vg versus the reciprocal of the absolute temperature of the column. Such a representation is called retention diagram or Van't Hoff retention diagram. This variation is generally linear and the slope is related to the enthalpy of the process, solution in the liquid stationary phase or adsorption on the solid surface, if solid material is in the column. The Van't Hoff retention diagram displays a linear relationship so long the sorption process (adsorption or absorption) is invariant. It is not the case if a transition phenomenon occurs. We will then observe singularities as shown on the figure here after. Example of Van't Hoff retention diagram, highlighting the glassy transition temperature (Tg) and the melting point (Tm). The AB segment corresponds to a temperature domain, in which the polymer is under its glass transition temperature (Tg). In this temperature domain, only the adsorption at the polymer surface influences the retention process. The point B corresponds to the glass transition temperature. Then, the penetration of the probe into the polymer mass starts and non-equilibrium conditions prevail to the point C where the probe can access all of the amorphous domains. The variation of ln Vg in function of the reciprocal temperature becomes again linear until the fusion point Tm is approached. The fusion of the crystalline domains leads to an increase of the retention volumes. At the point F, the fusion temperature Tm is reached. Thereafter, the segment FG, corresponds to the sorption process into the melting polymer layer, and a new linear relationship is observed. The crystallinity ratio of the polymer phase could also be determined thanks to this diagram. For that purpose, the segment GF is extrapolated to the point E having the same abscissa than the point D, which matches at the beginning of the fusion of the crystalline domains. In fact, the ordinate of E would be equal to the measured value if the polymer would be completely amorphous. A crystallinity ratio can then be calculated. For the study of the transition temperature IGC analysis is complementary, e.g., to the DSC. In the case of polymers deposited in very thin layers on a solid, IGC is more interesting. Indeed, for very low polymer amounts, DSC is no more enough sensitive. The next example highlights the influence of the impregnation ratio of pyrogenic silica by PMMA, on the glass transition and β transition temperatures, detected by IGC. Retention diagrams of n-octane for a PMMA impregnated pyrogenic silica (in number of monomer unit (UM) by nm2) [Hamdi and al (2002)]. A: Detection of the β transition of the PMMA at 60°C. B: Detection of the glass transition of the PMMA at 105°C. We observe that the positions of these two transitions are independent of the impregnation rate. However, the intensity of the observed jump increases with it. This suggests that the adsorption on a surface does not disturb the most monomers units. The great sensitivity of this method is underlined by the fact that the transitions are still detected for a coverage ratio of only 1 UM/m2. This is corresponding to an impregnation rate of only 2,2% in mass. Therefore, IGC is a well-adapted method for the study of the thermal properties of coating or sizing. Finally, we can underline that the evolution of the superficial properties of a solid impregnated under a controlled way by a polymer can be an approach allowing to obtain information concerning the intensity of the interaction occurring between the solid surface and the macromolecule.

Component, Device & Product Manufacturers · 11–50 employees · United Kingdom
2 listed under this category
Li-Ion Battery Testing
Li-Ion Battery Tasting Li-Ion batteries dominate the energy storage in both portable and as fixed power installations in Electrical vehicles. Testing of these devices is by nature time consuming as they undergo charge and discharge cycles while the open circuit voltage is monitored as function of time, sometime taking up to 3 weeks for the process to qualify the batteries. We address these issues by using advanced Quantum Well Hall Effect (QWHE) sensors as a novel solution to enable a new paradigm in high resolution mapping of the magnetic fields inside the battery. Any flaws will manifest as magnetic "hot spots" that can very quickly check the state of health of the battery and therefore potentially lead to substantial savings in the testing of the batteries by reducing test times from tens of days to less than day or hours for defective batteries as the flaws can be "caught" very early in the qualification process. The magnetic imaging of batteries is thus seen as critical for the structural health integrity and safety of these devices in a range of industries, from consumer electronics to electrical vehicles.
Cryogenic Temperature Performance Testing
Measured Linearity is excellent over the full range of fields from 0 to 0.5T with the maximum deviation from fitted straight lines being less than 0:5 %. For measured Hall voltage for magnetic fields from -1 T to 1 T, linearity over the full range has a maximum deviation from fitted straight lines of less than 1%. Between 4K and 300K, changes in input and output resistances are due to the much lower resistances (higher mobilities) at cryogenic temperatures. However, the variation in sensitivity is of order 10% across the entire range for all sensors from 4K to 300K.

Contract & Professional Service Providers · 1–10 employees · United States
2 listed under this category
Optical Calibration
Do your polarization optics satisfy the accuracy requirements of your device or sensor? Don't spend precious time on diagnostics and troubleshooting due to under-specified optics. AOT can measure and calibrate your polarization optics with our metrology polarimeters to better than 1% overall elemental error at various laser wavelengths and provide corresponding CAD files for use in optical-design programs. Benefits Obtain Comprehensive Specifications Understand effects for any input polarization state Improve Accuracy and Control Work with smaller signatures and lower SNRs Empower CAD Models Describe actual states and observable data Reduce Development Costs Save time and reduce trial-and-error development Applications Any optical device or sensor that controls or measures polarization will benefit from accurate calibration and comprehensive specifications. These include instruments that characterize nanostructures, fiber composites, textiles, plastics, and semiconductor & optical thin films, microscopes for metallography, crystallography, pharmaceutical chiral analysis, and biomedical tissue assays, telecopes for astronomy, lidar, and laser communication and quantum cryptography. Bring your application and AOT will improve your performance. Statistics Batch variation of commercial polarizers
Measurement Services
Advanced Optical Technologies (AOT)'s measurement services span from laboratory to field. AOT provides complete polarization signatures of samples at various wavelengths with better than 1% overall elemental error in measured Mueller matrices. Lab materials span from optical crystals to metallographic samples to diffuse ground materials. Other materials measured and validated in sensor applications include plastics, paints, textiles, and fiber-composites.

Contract & Professional Service Providers · 201–500 employees · United States
2 listed under this category
Opto-Electronic Test
Our extensive opto-electronic measurement capabilities allow you to invest your valuable resources in technology development and leave the testing to us. We offer comprehensive on-wafer, die-level, and packaged-device testing services for both photonic and electronic devices. Capabilities include: - Passive Optical - insertion loss, propagation loss, spectral, group index/velocity - Active Optoelectronic - modulation (Vπ L), detector responsivity, laser LIV - Telecom/Datacom - eye-diagram, optical modulator and photodiode bit error rate testing - RF - S-parameters, detector bandwidth - DC - DC IV, leakage current measurements using a multi-contact DC probes
Inline Control and Test (ICT)
Robust optical testing for photonics applications using inline and stand-alone approaches. Features: high-throughput, high-functionality wafer-scale optical probe test; on-wafer photonic test cells for process control; and multi-channel I/O fiber array test interfaces.

Nanomaterial & Chemical Producers · 11–50 employees
1 listed under this category
Claims Testing
Lab and pilot-scale validation that turns marketing language into substantiated, defensible claims. A cooling claim, an FR rating, or a humidity benefit is only as strong as the data behind it. Our in-house testing teams put every chemistry through standardized and customer-specific protocols — so what ships to consumers is what was promised. Methods we run in-house - Qmax / cool-touch (ISO and customer protocols) - Heat absorption and DSC thermal characterization - 16 CFR 1633, NFPA 701, and military burn specs - Wash-durability cycling and accelerated aging - Humidity buffering and microclimate measurement Built for regulators and brand teams Our reports are written to satisfy the technical reviewers at retailers, regulators, and certification bodies — not just internal R&D. When a claim needs defending, the data is already in the right format. Pilot-scale validation We bridge bench results to production by running pilot trials on full-scale finishing equipment, so the chemistry that wins in the lab is the chemistry that wins on the line.

Contract & Professional Service Providers · 11–50 employees · Canada
1 listed under this category
Measurement
Our measurement services are available in the wavelength range of 1530 - 1565 nm. The smallest available step size is 1 picometer and we can measure three channels simultaneously.

Equipment & Instrumentation Manufacturers · United Kingdom
1 listed under this category
Aquila nkd thin film measurement
Complete thin film measurement The Aquila nkd is used for a wide range of optical metrology applications including QC and process development. A small selection of application notes are presented here for your interest. If you would like to discuss a particular thin film measurement application, please feel free to contact us. The flexibility of the nkd makes it suitable for measuring the photometric performance, film thickness, refractive indices, absorption and uniformity of amongst others: Ophthalmic lenses• Sunglasses• Flat panel displays • Surface Coatings & Treatments • Precision optics• Semiconductors • Telecoms components • CD & DVD optical systems • Solar control glass and coatings• Automotive lenses • Visors • Packaging materials