XPS and AFM surface chemistry analysis.
Showing all 80 providers

Equipment & Instrumentation Manufacturers · 51–200 employees · United Kingdom
2 listed under this category
Surface Chemistry
The term surface, or interface, is used to describe the boundary between two different phases; a platinum catalyst and its operating environment, for example.
Electrocatalysis & Electrocatalytic Studies
Electrocatalysis sits at the intersection of electrochemistry and materials science, focusing on reactions that occur at electrode surfaces.

Government & National Laboratories · 1–10 employees · France
1 listed under this category
Atomic Force Microscopy (AFM)
Atomic force microscopy is used in the laboratory for the micrometric and nanometric scale characterization of semiconductor surfaces (nitrides of III elements (Ga, Al, In), SiC, BN, MoS2, etc.), conductors (NbN, graphene, etc.) and insulators (sapphire, MgO, etc.) studied in the laboratory by measuring the interaction forces between the atoms on the surface and the atoms at the tip of the microscope. The imaging mode mainly used in the laboratory is the intermittent mode (tapping mode TM). The CRHEACAM platform has two atomic force microscopes (AFM) manufactured by Bruker. One is the Nanoscope IV Dimension 3100, which can image samples up to 4 inch in size with a surface scan ranging from 0.25 mm2 to 2500 mm2. The other is the Dimension Edge, equipped with TM mode, which has similar characteristics to the Dimension 3100 and can study samples up to 8 inches in size without cutting. This non-destructive feature is beneficial for characterizing the surface of larger substrates, which are important for the development of a greater number of components. AFM Dimension 3100: Lateral resolution of 5 nm Vertical resolution of 10 pm TM mode characteristics: - Stiffness constant (k) of 42 N/m - Resonance frequency (f0) of 320 kHz AFM Dimension Edge: Lateral resolution of 5 nm Vertical resolution of 10 pm TM mode characteristics: - Stiffness constant (k) of 42 N/m - Resonance frequency (f0) of 320 kHz Peak force ScanAsyst characteristics: - Stiffness constant (k) of 0.4 N/m - Resonance frequency (f0) of 70 kHz

Contract & Professional Service Providers · 1–10 employees · France
9 listed under this category
Inverse Chromatography
Inverse Chromatography is designed to mesure physicochemical properties of materials and surfaces. The above figure illustrates the fundamental difference between classical GC and IGC. The two analytical methods are distinguished by the object of the study: on the left, the blend to analyse, on the right, the solid contained into the column. In order to perform such determinations, the role of the mobile and of the stationary phase are inversed. Here it is the stationary phase that is analysed. This implies to fill a column with the material to be characterized. The filling of the chromatographic column Hence, the first step of an IGC analysis is the filling of the column with the solid of interest. This is also the first critical point. The technique to fill columns with ideal powders having monodisperse granular size, i.e. similar to standard chromatographic stationary phase like Chromosorb®, is well known. But, Inverse Chromatography often deals with very divided solids, having a mean particle diameter of few microns (fillers for polymers like talc, silica or carbon black) or with fibres (textile fibres or hairs, for example). Of course, each type of solid is a particular case, requiring an adapted filling protocol. Our experience, acquired through thousands analyses, allows us to find quickly a satisfactory protocol, which respects the surface state of the analysed solid. The ILC or IGC measurements are realized by injecting chosen and known molecules, called molecular probes, in order to get chromatograms. Obviously, the measured retention times, as well as the shape of the obtained peaks, are depending on the interactions occurring between the molecular probes and the investigated material (stationary phase). Therefore, the exploitation of measured retention times and/or of the shape of the chromatograms gives access to numerous physicochemical properties of the analysed materials. The IGC is the most common Inverse Chromatography technique. Two IGC methods exist depending on the injected molecular probe amounts: - The IGC at infinite dilution (IGC-ID) method is so called because very low amounts of molecular probes are injected. In such situation, the interactions between the molecular probes are negligible and the retention time is only depending on the interactions occurring with the investigated stationary phase. IGC-ID is applied to characterise the properties of solid surfaces but also to determine transition temperatures and characterize liquids (ex. molten polymers) for the determination of solubility parameters. - The IGC at finite concentration (IGC-FC) method consists of injecting a more important molecular probe amount. The reached surface coverage ratios are close to the monolayer or even higher. This method is applied mainly in gas/solid chromatography with the goal to determine desorption isotherms, specific surface area and measuring the surface heterogeneity. The Inverse Chromatography techniques are powerful tools for the R&D departments and Quality control. The application fields are wide and numerous physicochemical properties are measurable. Inverse Chromatography measures the interaction potential of the materials and of their surfaces. But, the more important point is that Inverse Chromatography measures the interaction ability of the investigated materials. In that way, these techniques are complementary to spectroscopy and microscopy. Spectroscopy informs about the chemical composition, Microscopy informs about the surface texture and the morphology. Inverse Chromatography delivers how chemistry and morphology act together on the interaction potential and the physicochemical properties of the material.
Inverse Gas Chromatography at Infinite Dilution (IGC-ID)
The inverse gas chromatography at infinite dilution (IGC-ID) consists in injecting very small amounts of probe molecules into a chromatographic column containing the solid to be investigated. The degree of dilution is such that intermolecular interactions between the adsorbed molecules can be neglected. Practically, a pulse of very diluted vapour of probe molecules is injected into the column. Pushed by the carrier gas, the probe molecules explore statistically the whole surface of the solid before leaving the column. The flow of solute molecules leaving the column is then detected and recorded. A chromatogram is then obtained then as displayed on the figure hereafter. Analysis of the chromatogram. When progressing inside the CG column, the probe molecules undergo numerous adsorption-desorption cycles. Hence, they stay adsorbed on the stationary phase for a short or longer time, depending on the intensity of the interactions exchanged between the probe and the solid surface. The average time spent by the solute probes in the adsorbed state is known as the neat retention time (t_N). The value of t_N is equal to the difference between the retention time of the peak of the probe and the retention time of a non-retained probe like the methane (t_0), which doesn't adsorb at the measurement temperature. t_N = t_R - t_0 Generally the taken value for t_R corresponds to the first order moment of the peak of the probe. From neat retention time value t_N, we deduce the volume of the carrier gas required to push the solute out of the chromatographic column. This volume is known as the net retention volume (V_N) and is computed by multiplying the net retention time by the flow rate (D): V_N = D. J. t_N Where J is the James Martin coefficient that takes into account the expansion of the gas inside the column bound to the pressure gradient. J is given by the following equation where P_E is the entering pressure and P_A the atmospheric pressure. J = 3/2. ((P_E / P_A)^2 - 1) / ((P_E / P_A)^2 - 3) Starting from the V_N value of one or several probes it is possible to determine: - The solubility parameters of a deposited polymer (melted) on a chromatographic support, by injection of a series of chosen probes. - The diffusion coefficient of probes into a thin polymer film supported by a solid. - The standard free energy change of adsorption ΔG_a° of the probe on a solid surface. The chromatographic process results from the equilibrium between the mobile phase and the stationary phase. For a solid, V_N is connected with the equilibrium constant (K) and the total adsorption area (A) of the solid contained in the column as follows: V_N = K. A Specifically at infinite dilution conditions, V_N is directly related to the standard free energy change of adsorption ΔG_a° of the probe on the surface, by: ΔG_a°(probe) = - R. T. ln(K) = - R. T. ln(V_N) + C Where C is a constant depending on the choice of a bi-dimensional reference state. For melted polymers, the tri-dimensional reference state is usually used. But for the adsorption on a solid, quite arbitrary bi-dimensional reference states have been proposed. Most of them are assuming the surface homogeneity. But the real solid surfaces are in general more complex and heterogeneous. Therefore, the application of these bi-dimensional reference states was considered as inappropriate. The most often, the authors overcome the choice by computing the free energy change of adsorption as follows: ΔG_a(probe) = - R. T. ln(V_N) It is also possible to determine parameters that are independent of the reference state: - The adsorption enthalpies obtained from the variation of the free energy with the temperature. The study of their variation with the temperature allows the detection of transition temperature of the first order or the second order. - The free energy increments of homologous series of linear alkane or oligomers allow acquiring data related to the surface energy. Doris and Gray have taken this approach to develop a determination method of γ_s^d, the dispersive component of the surface energy.
Inverse Gas Chromatography at Finite Concentration (IGC-FC)
Inverse Gas Chromatography at finite concentration conditions (IGC-FC) is a dynamical method providing readily adsorption isotherms. The usual procedure, called ECP (Elution at the Characteristic Point), allows to determine from a single chromatographic peak part, the isotherm of desorption for relative pressures (P⁄P 0)(P/P 0) ranging from near zero to 0.3 and above. This kind of chromatography is performed by injecting, usually in the liquid form, known amounts of solutes (molecular probes) in the GC column containing the solid of interest. Depending on the nature of the solids, those quantities are between a tenth and some twenty microliters (μ L μ L). After the injection, the solutes are vaporized. Carried by the “carrier gas”, the solutes occupy successively the whole surface of the solid before being ejected. The solute flow is then detected and recorded. Analysis of the chromatogram. The analysis of the chromatogram, as depicted here above, leads to desorption isotherms and adsorption energy distribution of the sites explored by the solute molecules. Determination and exploitation of the desorption isotherms The analysis of the diffuse front of the chromatogram readily provides the desorption isotherm of the injected probe molecule. The first derivative of the isotherm is directly related to the neat retention time characterized by each point of the chromatogram.(∂N∂P)L,t R=1 R.T.D c m.(t R−t 0) L is the length of the column, N is the number of molecules at each point, P is the adsorption pressure, t R is their retention time and t 0 (the retention of a poorly adsorbing solute such as methane) allows to calculate the dead volume. D c is the corrected gas flow and m the mass of solid inside the column. Furthermore, the solute pressure is directly related to the height of the signal at the given point. The chromatogram delivers all necessary information for the determination of the desorption isotherms. Domains of the isotherm. The computed isotherms are split into several domains, as depicted on the above example. The first domain, located at low relative pressure, corresponds essentially to strong solute-solid surface interactions. This represents the linear part of the isotherm whose slope provides the Henry constant (KHenry). The part of isotherm corresponding to relative pressures between 0.05 and 0.3 allows the evaluation of the specific surface area and BET constant by application of the BRUNAUER, EMMETT and TELLER (BET) theory. That part of the isotherm describes weak solute-solid interactions whereas solute-solute interactions become prevalent. The final part of the isotherm, where multilayer formation occurs, is usually not considered in chromatography. Determination of the surface energetic heterogeneity All solid surfaces are heterogeneous. This heterogeneity has various origins: geometrical, energetic or chemical. IGC-FC delivers a “fingerprint” of the surface heterogeneity in the form of adsorption energy distribution of the various sites. Moreover, this method, using probe molecules of different morphology and functionality, allows acceding to the different aspects of the surface heterogeneity. Yet the actual determination of those distribution functions is far from being evident. The paper by Charmas and Leboda lists the difficulties and suggests the solutions proposed by the various authors. The mathematical problem stems from the resolution of the first order Fredholm integral function that gives access to the energy distribution χ(E)). No simple way exists to solve that problem:N(P m,T m)=N 0.∫E m a x E m i n θ(E m i n)(E,P m,T m).χ(E).d E N(P m,T m) is the number of adsorbed molecules at pressure P m and at temperature T m.N 0 represents the number of molecules required to form a monolayer. θ(E,P m,T m) is the local isotherm and E the adsorption energy on a given site. The physicochemical problems are related to the validity and meaning of the simplifying hypotheses that allow the resolution of the integral. They also stem from the ignorance of the solute-solute interactions that significantly intervene at the higher degrees of solid surface coverage’s. To overcome those problems, one may apply the method developed by Balard (1997). For the sake of simplicity, the mathematical approach will not be given here. Only the hypotheses behind this approach will be discussed. The first step is the correction of the multilayer part of the adsorption isotherm to restrict the interpretation to the sole probe-surface interactions. Thereafter, the computing of the distribution function with the condensation approximation (CA) is performed (FDCA). The model of the surface is the patchwork as shown here after, where each domain is supposed to be homogeneous. Patchwork model. Each domain is described by a “local” isotherm”. The sum of the local isotherms reconstructs the observed (but multilayer corrected) isotherm. The condensation approximation greatly simplifies the FREDHOLM equation by reducing the local isotherm θ(E,P m,T m) to a constant value (0, 1/2, or 1), depending on the adsorption energy and characteristic pressure of the sites. Example of FDCA: adsorption of heptane, at 40°C, on a carbon black. The FDCA are generally rather coarse as depicted here above. The resolution of those functions is improved when eliminating the computation background noise, and applying the RUDZINSKI-JAGIELLO method. The method of BALARD smoothes the FDCA using FOURIER series that easily gives access to multiple derivatives required in the RUDZINSKI-JAGIELLO method. Those energy distribution functions allow to observe the various components that constitute the FDCA. As an example, the figure hereafter presents the results obtained with heptane (at 40 °C) on various carbon materials. Distribution functions determined with heptane (at 40°C) on Graphite and Carbon Blacks. Molecular probes (adsorbates) The characteristics of the molecules able to be used as probes are the following: - vaporisable, - must be detected by the instrument, - thermally stable during the experiment, - only able of reversible adsorption, - eluted in a reasonable time. The classical used probes are: - n-alkanes (pentane→dodecane), - branched and cyclic alkanes (pentane→octane), - Polar molecules - alcools, acids, ethers, ketones, esters… - amines… - aromatics… The advantage of this method is to be able to perform measurements at temperatures close to the application and with molecules representative of the application.
Inverse Liquid Chromatography (ILC)
Principle Since the beginning, chromatography was also applied in order to carry out physicochemical characterizations. The earliest mention of physicochemical measurements by gas chromatography was in 1947, when Glueckauf pointed out that adsorption isotherms could be determined from the breakthrough curves of gas-solid chromatography. For such purpose, the adsorbent (solid to investigate) is used as packing material for the column instead of the classical chromatographic phase. The adsorption capacity of the adsorbent is then evaluated by injecting a chosen adsorbate. In other words, the adsorbate plays the role of a molecular probe. Because of the inversion of the respective role of the mobile and the stationary phase, this kind of chromatography is called “Inverse Chromatography”. We may distinguish several “Inverse Chromatography” techniques depending on the used mobile phase (gas or liquid) and on the amounts of injected molecular probes. When a liquid is used as carrier phase, the corresponding Inverse Chromatography technique is called Inverse Liquid Chromatography (ILC). This technique offers a dynamic way to study the adsorption in liquid media of various molecular probes onto powders, particles or fibers. Low molecular weight molecules, but also macromolecules or surfactants could be used as probes. The obtained informations are: - adsorption isotherms, - desorption isotherms, - the amount of irreversible adsorbed probes. Irreversible adsorption In some cases, strong solute adsorption can arise. This could result either from chemical reactions occurring between the solute and the adsorbent surface or by strong physisorption of the solute on the adsorbent. Such a phenomenon is observed on the figure, here above, that compares the chromatograms obtained after two successive identical injections of the same solute (presently octyltriethoxysilane) on silica. We notice that the desorption profile of both chromatograms is identical. In contrast, their adsorption profile looks very different. Generally, the second and the next injections give reproducible chromatograms. But when “irreversible“ adsorption occurs, the first injection gives a narrower chromatogram. Since, the chromatogram areas are proportional to the eluted solute amount, we can conclude that the chromatogram area difference corresponds to the “irreversibly“ adsorbed solute amount. On the figure, this amount is depicted in grey. Reversible desorption isotherm The most common way to determine desorption isotherms is to practice the so called “frontal chromatography”. In such experiments, the desorption profile, or rear boundary, is obtained at the adsorption equilibrium and may therefore be used to compute the isotherm. Hence, at each point of the rear boundary, an equilibrium concentration C and the corresponding adsorbed amounts Q_{a d s} are determined. The amount adsorbed is calculated by computation of the area under the peak, starting from the tail end (C = 0). Q_{a d s} = ∫ {0}^{C} ( V - V {0} ). d C where Q_{a d s}is the amount of compound adsorbed by 1g of the column packing, under equilibrium at concentration C and V and V_{0} are the retention volumes, corresponding to the point of the diffuse profile, at concentration C, or characteristic point, respectively of the experimental profile and for the theoretical injection profile. Thus, each point of the rear profile gives one point of the isotherm. In a same manner, isotherms of adsorption can also be measured. However, for that purpose, the injection profile must be changed. The use of a gradient of concentration is probably the best adapted profile. In order to get further information, the obtained curves were fitted assuming an isotherm model. The most used remain the single Langmuir type isotherm model. The following relation describes this model: Q_{a d s} = Q_{0}. (b. C)/(1 + b. C) This model supposes a homogeneous surface from a point of view of its properties and also a maximum adsorbed quantity limited to a monolayer of adsorbed molecules (Q_{0}). The mathematical tools make it possible to find easily the values of the parameters b and Q_{0} that best describe the experimental isotherms. However, it happens that the Langmuir model describes only imperfectly the isotherms. In such cases, one calls upon other models. These models are: - The bi-Langmuir model: Q_{a d s} = Q_{0, 1}. (b_{1}. C)/(1 + b_{1}. C) + Q_{0, 2}. (b_{2}. C)/(1 + b_{2}. C) with Q_{0} = Q_{0, 1} + Q_{0, 2} - The Freundlich model: Q_{a d s} = k. C^{1/n} where k is a constant and n a heterogeneity factor. - The Redlich-Peterson model: Q_{a d s} = k_{R}/(1 + a_{R}. C_{β}) where k_{R}, a_{R} and β are constants (0 ≤ β ≤ 1). Advantages and limitations of ILC Advantages: - Determination of adsorption and desorption isotherms in a unique experimental run. - Irreversible adsorbed probe amounts determination ( ). - Only few sample, probes and solvent amounts are needed for such determinations (compared to static methods). - Quick determination of the isotherms once the protocol drawn up. - Experiment conditions often close to the industrial process. Limitations: - Protocols sometimes long and delicate to develop. - Sensitivity of the detectors. - Solvent’s cut-off sometimes handicapping (UV). - Variations between probe’s and solvent’s refractive indexes sometimes too weak.
Surface morphology
Ligner et al. (1989-1990) measured the value of the dispersive component of the surface energy ($\gamma_{s}^{d}$) of H-Magadiite at around 285 mJ/m 2. Such a value is especially high. They also observed that the octane branched isomers were eluted about 10 times faster than their linear isomer n-octane. Obviously, such a difference cannot be justified by the difference in polarizability induced by the alkane branched structure. The structure of H-Magadiite being lamellar and able to intercalate organic molecules, the authors attributed this particular behaviour to the inclusion of n-alkanes in some sites, which were inaccessible to branched probes due to a size exclusion phenomenon. The appreciation of the importance of the size exclusion phenomenon requires an adapted molecular descriptor that takes into account the influence of the structure on the polarizability. Brendlé and Papirer (1997a) proposed the $\chi_{T}$, a molecular descriptor based on the Wiener index ($W$). Wiener introduced his index in 1947 that is the oldest topological index related to molecular branching. It was shown that the Wiener index number is closely correlated to numerous physicochemical properties of the molecules (e.g. the boiling points of alkane molecules). Other works on quantitative structure–activity relationships showed that it is also correlated with other parameters like density, surface tension, viscosity and the Van der Waals surface area and volume of the molecule. Therefore, $W$ and$\chi_{T}$ can also be employed to describe the polarizability of the molecules i.e. to their capacity to exchange dispersive interactions. Moreover, a linear relationship between the polarizability and$\chi_{T}$ was found (Balard et al. 2000a). The main advantage of the latter is that they can be calculated for probes, for which no data is present in the literature. The figure hereafter displays the chromatograms acquired for some linear alkanes probes and for isooctane, on a solid exhibiting a strong size exclusion effect for branched isomers. This figure also displays the diagram (left) obtained when plotting the free energy of adsorption of the probes versus their descriptor ($\chi_{T}$). Plot of the free energy change of adsorption ($\Delta G_{a}$) of alkane probes versus $\chi_{T}$. On this chromatogram, the hollow signal shows the position that the isooctane peak would have if no exclusion phenomenon would exist, i.e. if the surface is planar at the molecular level.On the left diagram,the corresponding representative point (the hollow circle) is then situated on the alkanes line. This is what is observed, for example, in the case of some pyrogenic silicas having a mean surface area value. The flatness of such pyrogenic silicas (S BET=130 m 2/g) was confirmed by other methods. In contrast, if the surface is nanorough some size exclusion effect exists and the isooctane probe takes place bellow the n-alkane straight line (black circle). The exclusion of isooctane from sites, in which n-alkanes could be inserted, will induce a decrement of free energy$\delta \Delta G_{a}^{M}$. This decrement is equal to the ratio of the measured retention volume of the branched probe ($V_{N}$) on that it would have if it was not excluded ($V_{N}^{r e f} \left.\right)$. The morphology index $I M$ is then defined according to the equation: $$ I M = exp \left[\right. \delta \Delta G_{a}^{M} \left]\right. = \frac{V_{N}}{V_{N}^{r e f}} $$ Thus a value equal to 1, or very close, indicates that the surface accessibility of branched molecules is identical to that of linear alkanes. Thus, the surface could be considered as flat at the molecular level. If the morphology index is less than 1, then a surface nanoroughness takes place. Lower the morphology index is, the higher the surface roughness at the molecular level is. Some example of measured $I M$ values are given on the table hereafter. Examples of $I M$ values Solides S (m 2/g) $I M \left(\right. \chi_{T} \left.\right)$ Cyclohexane DiMethylHexane TriMethylPentane TetraMethylButane Silice 130 0.95 0.91 1.1 1.1 Talc 4 0.52 0.32 0.41 H-magadiite 80 0.19 0.13 0.09 0.11 We observe that these size exclusion effects are very common, the flatness the exception. Pyrogenic silicas of high specific surface area exhibit a high surface roughness associated to the imperfect coalescence of protoparticles at the nanoscale (Balard et al. 2000b). For lamellar solids, like clays and talcs, the surface roughness is due to the presence of like slot sites present on the side surfaces of the crystals (Comard et al. 2001a). In the case of carbon black, the phenomenon of exclusion is related to the particular structure like fish scales made of graphite planes, proven by STM (Calvet et al 2012), then the n-alkane probes could be inserted at the edge of the scales. It is also important to note that the nanoroughness of the surface explains the measured high $\gamma_{s}^{d}$ values. Indeed, nanoroughness implies that the adsorbed n-alkane probes are probably in contact with more than one surface. In other words, the dispersive interactions between the surface and the probes become even stronger. The molecular descriptor $\chi_{T}$ used to estimate the surface roughness, could be also used to describe molecules comprising heteroatoms, i.e. polar molecules. Therefore $\chi_{T}$ is also useful for the measurement of the strength of the specific interactions with the surface.
Hansen Solubility Parameters (HSP) determination by IGC-ID
The Hansen Solubility Parameters (HSP) were initially developed by Charles M. Hansen in 1967 as a tool for predicting if one material will dissolve in another and form a solution. Today, they are not only limited to predict solubility of chemical components but they are also used to optimize the stability of particle suspensions or the adhesion of polymers on surfaces. Therefore, the HSP were considered as a useful means to accelerate the development of formulations of inks, paints, adhesives, cosmetics or pharmaceutics. The HSP are based on the idea that 'like dissolves like' or, in the case of solid surfaces to 'like seeks like'. Each component, molecule or solid surface is described by three HSP parameters (δ), generally measured in MPa1/2. The three δ parameters are also called cohesion energy parameters: - δd The energy from dispersion forces between molecules - δp The energy from dipolar intermolecular forces between molecules - δh The energy from hydrogen bonds between molecules. These three parameters can be treated as coordinates for a point in three dimensions also known as the Hansen space. The nearer two molecules are in this three-dimensional space, the more likely they are to dissolve into each other. To determine if the parameters of two molecules [usually a solvent (2) and a polymer (1)] are within range, a value called interaction radius (R0) is given to the substance being dissolved. This value determines the radius of the sphere in Hansen space and its center is the three Hansen parameters. To calculate the distance (Ra) between Hansen parameters in Hansen space the following formula is used: R2a=4(δd2−δd1)2+(δp2−δp1)2+(δh2−δh1)2 The relative energy difference (RED) of the system is defined as follows: RED=RaR0 If RED<1, the components are alike and will dissolve. If RED=1 the system will partially dissolve. If RED>1, the system will not dissolve. Hansen Solubility Parameters and IGC The HSP are related to the interaction ability of molecules with other species. On the other side, IGC-ID is a method dedicated used to measure the interactions between a solute and a stationary phase (liquid or solid). Therefore, methods to determine the Flory-Huggins interaction parameter (χ∞1,2) and the HSP values of polymers from the IGC-ID measurements have been first developed by Lipson and Guillet. The proposed method consists in placing equally a controlled amount of the polymer to characterize on an inert support, like Chromosorb® or silanized glass beads. The measurements are generally carried out at temperature significantly above the Tg of the polymer. They consist in determining the retention times (tN) of three families of solvents: apolar, polar and those able of hydrogen bonding. These retention times are then converted into specific retention volumes (V°g) as follows: V°g=273.15T.Dcms.tN with T, the measurement temperature [K], Dc the corrected carrier gas flow and ms the weight of deposited polymer. Several relationships have been proposed in order to compute χ∞1,2 from the measured V°g values. We use the one proposed by Adamska and Voelkel: χ∞1,2=ln(273.1M1.V°gP01.R)−P01R.T(B11−V01)+ln(ρ1ρ2)−(1−V01V02) The above equation indicates that numerous of physicochemical parameters of both molecular probes and coating (or polymer) are needed. Some of them must be computed using other physicochemical characteristics. This is the case of B11 the second Virial coefficient of the probe. The difficulty comes from the fact that some data are difficult to find. Sometimes, several sets of data exist in the literature and all of them are not suitable. To overcome these difficulties we choose to use the Software and database proposed by the professor Abbott: HSPiP. This Software is able to compute the HSP starting from any experimental V°g data. Of course, in order to perform the above computations, the density (ρ2) and the molar volume (V02) of the polymer must be known. The solubility parameter can also be calculated using the method proposed by Voelkel [2007] using the following equation: δ21RT−χ∞HV01=2δ2RT.δ1−δ22RT with χ∞1,2=χ∞S+χ∞H, δ1 the solubility parameter of the probe and δ2 the solubility parameter of the investigated substance. Assumptions are made about the value of χ∞S in order to accede to χ∞H. The tested solutes used in IGC-ID experiments can be divided into three groups, representing different intermolecular interactions: dispersive, polar and hydrogen bonding. Plotting a linear relation for each group of tested solutes, according to the above equation, the components values (δ2d, δ2p and δ2h) of the total solubility parameter δ2 can be calculated from the slope (Sχ) of a straight line using the following relationships: δ2d=Sn−alkanes2RT δ2p=(Spolars−Sn−alkanes)2RT δ2h=(Sh−bonds−Sn−alkanes)2RT δ22=δ22d+δ22p+δ22h Obviously, the great advantage of the use of IGC-ID is the quickness of the HSP value determination. Moreover, the required amounts of tested solvents and of the investigated material are very low.
Determination of the specific interaction parameters (ISP)
The specific or polar interactions involve all type of interactions except the dispersive interaction or London interaction by instantaneous dipoles. They can be polar, ionic, magnetic, electric or acid-base. These acid-base interactions are largely predominant according to Mittal and Anderson (1991). Just as for the morphology indexes, the specific interaction parameters (ISP) will be determined with reference to the n-alkane straight line. This is achieved by considering that the gap of free energy change of adsorption between the representative point of the polar probe (ΔGa) and its projection on the alkanes straight line (ΔGad), will correspond to the contribution of the specific interactions (ΔGaSP). So the ISP of a probe is given, in kJ/mole, by the following expression: ISP = ΔGaSP = ΔGa - ΔGad The figure hereafter illustrates the ISP determination method, which allows the easy splitting of the free adsorption enthalpy, into a dispersive term (ΔGad) and a specific term (ISP). Here, the molecular descriptor (χT) is calculated like for the alkanes, by taking into account the geometry of the polar probes [Brendlé and Papirer (1997b)]. As for the alkane probes, the χT parameters of the polar probes correlate well with the literature data concerning their polarizabilities [Balard et al. (2000a)]. Historically, other molecular descriptors have been proposed. So Saint Flour and Papier (1983) retained as parameter the logarithm of the vapour pressure of the probe (log(P0)). Then Schultz and al. (1987) proposed the product of the molecular area of the probe (log(P0)) by the square root of the dispersive component of its superficial pressure (γsd) that is (a.√γsd). The first parameter suffers to be related to the cohesion energy of the liquid, hence to the interaction energy between two identical molecules. The second parameter overcomes partially this fault, in referring to the dispersive component of the liquid. But it supposes also the knowledge of the adsorption area, which cannot exactly be known, because it varies with the conformation of the molecule in the adsorbed state. Despite that, it is still used. These limitations justify the choice of a descriptor (χT), which is directly related to the polarisability of the probe and easily accessible by computation. By diversifying the functionality and the acid-base character of the injected molecule, it becomes possible to have access on the acid-base character of the studied solid.
Determination of the dispersive component of the surface energy
This determination is performed with IGC-ID, i.e. Inverse Gas Chromatography at Infinite Dilution, and was first proposed by Dorris and Gray (1979). For that purpose, they measured the retention time (t_N) of a series of n-alkane molecular probes. With respect to the infinite dilution conditions, the measured retention times are directly related to their free energy change of adsorption (ΔG_a). With help of this linear behaviour, a free energy increment by methylene group (ΔG_a^CH2) is determined. It corresponds to the slope of the n-alkanes line. The n-alkane probes are non-polar and only able to exchange non-specific interactions with the surface (London Forces). Therefore, the work of adhesion of the methylene unit to a surface W_a^CH2, as described by Fowkes (1967), can be written. Since the adsorption and the work of adhesion are reversible, we can bring them closer. It is worth to underline that this approach supposes that the n-alkane probes adsorb flat on the surface and that the surface is homogeneous. The table below reports some range of values of the γ_s^d values measured on different types of solids: Polymer 25 to 60; Cellulosis >35 to 55; Calcium carbonate 33 to 110; Talcs 110 to 200; Carbon blacks 80 to 550. We can see that for a given type of solid, the dispersive component can vary in a large range. The dispersive interactions are strongly related to the polarizability of the surface. In the case of carbon blacks, a large variability of the measured γ_s^d values is observed. Especially, the highest values are measured on conducting carbon blacks. This can be explained taking into account the fact that, for these solids, the electrons are much mobile, i.e. more polarisable. But this explanation does not match for the calcium carbonates, neither for talc. Indeed, both solids are insulators and also show high variability of their γ_s^d values. One question arises: Are assumptions made for the computation of the γ_s^d value respected? More precisely: is the surface of the examined solid smooth and homogeneous? We will see that the IGC-ID is also able to give access to information about the surface morphology at the molecular probe scale.
Measurements & Contract analysis
The three main Inverse Chromatography techniques are proposed for measurement services are: - The Inverse Gas Chromatography at infinite dilution (IGC-ID - The Inverse Gas Chromatography at finite concentration (IGC-FC) - The Inverse Liquid Chromatography (ILC) Depending on your objectives, one or a combination of the three techniques is proposed. If necessary complementary analytical methods are also proposed: MEB, TEM, DSC, N 2 Adsorption (BET), TPD, Hg Porosimetry, particle size, zeta potential… Each “Smart Inverse Chromatography” service is realized with respect of a defined process with the goal to provide you the best of Inverse Chromatography. The proposed services concern numerous application fields and materials. The I.C. measurements can be performed on powders, fibres and plates. The required sample amounts are depending on different factors like the specific surface area and the strength of the interaction ability of the surface. Hence, the suitable sample amount can vary from some mg to some grams. Of course, after measurements, the samples are returned to the customer. The physicochemical features we deliver are useful to: - Compare batches amongst themselves, in order to highlight the properties differences explained by a divergent behaviour - Optimize agglomeration or powder dispersion - Solve problems related to powder granulation - Clarify problems related to adhesion or polymer reinforcement - Measure the hydrophilic-hydrophobic character of the surfaces - Establish Quantitative or Qualitative Structure-Properties Relationships (QSPR) Of course, the delivered physicochemical characteristics are also suitable to follow the surface properties changes induced by different treatments or by the ageing. Hence, these data are interesting for: - The choice of the most appropriate treatment - The optimization of the treatment (plasma, grafting, thermal, coating) - Determine if the surface is clean or not These services are realized in an interactive way, so that the customer can take advantage of the results and their interpretation. This process brings also a certain flexibility to the service and gives the opportunity to adapt it under realization.

Contract & Professional Service Providers · 1–10 employees · United States
1 listed under this category
Material Characterization
Well-designed, exploitable material characterization is the key to success for many devices and sensors. Accurate material measurements can also propel physical models through verification and extension. AOT can characterize properties of your materials, from microstructural or electronic anisotropies to particle size to surface roughness and modulation depth, all measurable by non-destructive laser probes. Direct material measurements, often to the nanoscale, complement laser measurements and elucidate additional material properties. Atomic-force microscopy (AFM) direct surface measurements can provide three-dimensional nanoscale parameters critical to many electrical, optical, chemical, biological, and mechanical processes on surfaces, and AOT's extended-range AFM (exAFM) can extend your surface understanding over wider frequency bands. Benefits Nanoscale Resolution Reveal structures and precursors at sub-optical scales Multi-Scale and Multi-Dimensional Characterization Understand material properties scalable to relevant topologies Data Visibility Get data in raw parsable, common language, and graphical formats Traceability and Long-Term Support Rely on perpetual calibration files and data accessibility Applications: Accurate characterization of engineered optical materials provides device and component calibration, while accurate material signatures enable modalities including orientation and cystallographic imaging. You bring the application and AOT will provide material data to fuel it.

Contract & Professional Service Providers · 1–10 employees · United Kingdom
5 listed under this category
Atomic Force Microscopy (AFM)
Surface roughness measurements, step height and particle imaging with sub nm resolution
White Light Interferometry (WLI)
Surface roughness measurement with sub nm resolution in Z scale. 0.5 um in X and Y.
Advanced Surface Analysis and Material Characterisation Services
We provide advanced surface analysis, material characterisation services and consultancy to high technology companies across the globe, aiding their early-stage R&D projects, product monitoring and critical failure analysis with clients across Europe, USA, and in the Far East. Combining a knowledge of material science with over three decades of expertise in advanced analytical techniques, we deliver bespoke metrology solutions for thin films, semiconductors, and nanolayers thereby supporting our customers to innovate, optimize performance and maximize their competitive advantage. We provide a confidential and responsive service. We focus on understanding your key specific technical issue and respond accordingly with pertinent customised solutions in a timely fashion
X-Ray Photoelectron Spectroscopy (XPS)
Quantitative analysis including chemical state information. Angle resolved mode for non-destructive near surface depth profiling
Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS)
High mass resolution with mass range 0-12000 a.m.u. Depth profiling using sub keV O or Cs beams (nm depth resolution) 2-D and 3-D ion imaging (100 nm lateral resolution ) Parallel detection - A significant benefit for detecting unknown contaminants at interfaces and analysis of unknown complex structures Retrospective reconstruction of data (including depth profiles) from any region of interest (ROI) post acquisition - off line. Also see DSIMS Applications High depth resolution dopant profiling Surface and interface contamination assessment (organic and inorganic) 2D and 3D chemical imaging and mass spectra Depth profiling of organic materials Reverse engineering Materials Semiconductor materials and processed devices Oxides, high k and low k dielectics Thin films and coatings Optical coatings Diamond and related materials Example of retrospective image and spectra reconstruction

Contract & Professional Service Providers · 51–200 employees · Sweden
1 listed under this category
Advanced Surface and Interface Characterization Solutions
World-leading analytical instrument solutions. At Biolin Scientific, we believe innovation should know no bounds. Our mission is to deliver game-changing analytical solutions that empower both industry and academia to shape a better future. Guided by teamwork, ownership, and simplicity, we work side by side with researchers and professionals worldwide to unlock new insights at the surface and nanoscale. Our expertise lies in advanced surface and interface analysis, helping you explore material properties and interactions with precision and reliability. From drug delivery and energy storage to coating technologies and beyond, our solutions empower you to optimize processes and accelerate discoveries.

Equipment & Instrumentation Manufacturers · 11–50 employees · Finland
2 listed under this category
MP-SPR Measurement of Thin Solid Films and Nanolayers
Thin solid films are typically applied as coatings ("nanolayers") to provide functionality to everyday products from electronics and phone displays through batteries, solar cells and packaging to automotive components and doorknobs. With BioNavis' novel configuration of Multi-Parametric Surface Plasmon Resonance (MP-SPR), we combine plasmonics to reach the Ångström level with a goniometric setup similar to that of ellipsometer to obtain a working range and multiple wavelengths similar to spectroscopic ellipsometry to define refractive index of each measured layer. This provides reliable measurements of thickness and refractive index of nanolayers, their plasmonic properties and surface interactions. Reasons to choose MP-SPR for measurements of thin solid films: - Measures ultrathin films from a few Ångström thickness thanks to measurement at wide angular range and multiple wavelengths - Thickness and refractive index solved simultaneously using LayerSolver™ - Extremely sensitive instruments for real-time adsorption kinetics on surfaces - From dry to wet state with the same configuration – MP-SPR works in both states due to its goniometric configuration - Cross-validation with microscopy and modelling is possible - Measurements do not require vacuum - Measurements can be performed in organic solvents Use MP-SPR to: - Select the best barrier (non-stick / antireflective / moisture) coating - Determine the minimum required thickness of nanolayers for desired functionality - Assess the quality of the coating - Find the coating process that provides homogeneous layer - Determine the time needed for nanoparticles to assemble on the surface - Find the ideal pH and electric potential conditions for the coating process - Assess layer swelling in contact with gas, moisture or solvent - Measure the SPR response of metal layers - Easy handling of sensor slides for ex situ modification We have a wide range of ready made sensor surfaces to choose from, or you can make your own coatings in your premises. We are glad to provide our expertise and measure your samples in our facilities. How can adsorption within porous coatings be measured? MP-SPR detects refractive index changes inside porous coatings, providing data on molecular adsorption. This is critical for optimizing porous materials for specific applications. How can adsorption within coatings be measured? MP-SPR detects refractive index changes inside coatings, providing data on molecular adsorption. This is critical for optimizing materials for specific applications. Does MP-SPR analyze the hydration of coatings? Yes, MP-SPR monitors optical thickness shifts caused by water uptake. By measuring the coated material in air and then in water, it is possible to extrapolate the water content associated with the film. How can responsive coatings be studied? MP-SPR captures dynamic optical changes in coatings that respond to stimuli such as temperature, electric potential, pH, or light. This is valuable for developing smart stimuli-responsive materials. Can QCMD evaluate the durability of coatings under stress? Yes, QCMD monitors coating degradation or delamination under conditions such as chemical exposure or mechanical stress. This helps assess coating robustness and performance over time. Is QCMD useful for analyzing multi-layered coating systems? Yes, QCMD can distinguish individual layers in multi-layered coatings by monitoring sequential changes in mass and dissipation during deposition of each layer. This is critical for optimizing complex coating designs.
QCMD
QCMD provides powerful tools for studying biomaterial interactions at the molecular level, offering insights that can inform the design and development of new biomaterials for biomedical applications. QCMD provides quantitative data on biomaterial properties, such as mass changes, viscoelastic properties, and binding affinities. This quantitative analysis enables researchers to characterize biomaterials more precisely and compare different materials or experimental conditions (including concentration, temperature, solvent, and pH) quantitatively. Benefits of QCMD in soft materials research are - Measurements possible in wet and dry environment - Measurements possible at different pH, temperature, electric potential - Layer thickness measured - On-line monitoring of Layer-by-Layer depositions - Layer viscoelasticity measured - Combination of QCMD with electrochemistry - Measurement is refractive index independent - Sensor slides can be modified / coated in situ or ex situ How does QCMD help optimize the surface properties of biomaterials? QCMD measures adsorption, hydration, and mechanical properties of biomaterial surfaces. This data is essential for fine-tuning biomaterials to achieve desired functionality. Can QCMD measure degradation of biomaterials over time? Yes, QCMD tracks real-time mass loss and dissipation changes as biomaterials degrade under various conditions. This provides insights into their stability and suitability for long-term applications. Is QCMD suitable for studying protein adsorption on biomaterials? Yes, QCMD quantifies protein adsorption on biomaterial surfaces. It also detects conformational changes, providing a comprehensive view of protein-material interactions. See beyond the surface. Contact us to find out how BioNavis instruments can enhance your research.

Equipment & Instrumentation Manufacturers · 11–50 employees · United States
9 listed under this category
Electrochemical SPR (EC-SPR) Technique
BI’S UNIQUE ELECTROCHEMICAL SPR TECHNIQUE ALLOWS SEAMLESS INTEGRATION OF SPR WITH ELECTROCHEMICAL MEASUREMENTS. Our electrochemical SPR technique is useful for a variety of applications: Anodic stripping analysis BI-SPR techniques combined with anodic stripping voltammetry are valuable in the detection of heavy metal ions at trace levels. This method is useful in screening biological/chemical analytes and monitoring trace levels of metal ions in surface water, soil, and other environment-related areas of research. Furthermore, it can be used in medical diagnostics for early detection of heavy metal poisoning. Electropolymerization, electrodeposition, and corrosion BI’s electrochemical SPR technique can be used to quantify both the amount of metal electrodeposited onto a surface and the reorganization of organic thin films upon redox reactions. By electroplating metal ions onto a gold sensor chip and detecting the SPR angular shift and electrochemical current signal, the type and amount of metal ions can be identified. Electropolymerization has also been the focus of increasing amounts of research due to its importance in such items as batteries and sensors, and its wide variety of applications in electrochemical technology. By using a three-electrode EC-SPR system, polymer thin films can be deposited on a gold film and monitored in real-time. Electrochemical research has continued to expand with the development of new polymer surfaces, which can easily be tested by using our interchangeable analysis modules. Immunosensing (e.g., ligand-receptor, antibody-antigen, etc.) Our BI-SPR techniques are very useful for label-free, real-time monitoring of the affinity and kinetics of antibody-antigen and ligand-receptor interactions. The concentration and distribution of target sites can yield important information about the functional consequences of binding, antibody characterization, immunogenicity, and more. Within research, antibodies have been used to elucidate details of biological processes and pinpoint therapeutic targets. Immunosensing is a powerful analytical technique that can be used for specific analysis and detection of a large variety of biomolecules, and our instruments provide the sensitivity necessary for superior results. Conformational changes of immobilized redox molecules Redox reactions are known to cause conformational changes in proteins and other molecules. Because these conformational changes are generally very small and fast, they can be very difficult to monitor. Here at BI, our instruments combine electrochemical and SPR techniques for a high-precision method to monitor the conformational changes of immobilized proteins taking place at or near an electrode surface. This, in turn, provides important information about the critical roles of these proteins and molecules in many different biological functions and processes. Our powerful and high-sensitivity detection technology delivers superior, high-quality data even for the fastest molecular processes. Potential-controlled molecular adsorption and charge transfer processes Electrochemical SPR studies can yield a wealth of information about the characteristics and kinetics of charge transfer chemical reactions and potential-controlled molecular adsorption and desorption processes. Certain proteins can be adsorbed onto a gold sensor surface via electrostatic interactions, the amount of which can be quantified and monitored by combining cyclic voltammetry and SPR techniques. BI’s SPR instruments have the sensitivity and precision to observe changes in optical properties due to protein conformational changes from the transfer of electrons. BI’s unique Flow Injection SPR technique allows SPR analysis to be carried out in one continuous stream.
Gas Phase SPR Technique
BI’s unique Flow Injection SPR technique allows SPR analysis to be carried out in one continuous stream. BI’S UNIQUE GAS PHASE SPR TECHNIQUE IS SENSITIVE TO PROCESSES OCCURRING AT SOLID-GAS INTERFACES. Our Gas SPR technique is useful for a variety of applications Fundamental solid-gas interface studies Unlike many other current SPR instruments, BI’s high-precision SPR instruments are designed with the capability for gas phase detection. They provide superior results for small-molecule detection and help to characterize polymers and thin films at solid-gas interfaces. By coating a metal film with sensing materials such as polymers, adsorption of the molecules onto the sensing materials can be detected by observing SPR angle shift. This feature enables the study of various molecular binding processes onto a modified surface from the gas phase. Detection of Toxic Molecules The use of fossil fuels has raised growing environmental concerns about air quality and toxic molecules in the air we breathe. Because BI’s SPR instruments are sensitive to processes occurring at the solid-gas interface, they can detect vapor interactions with various monolayers of molecular receptors. This paves the way for chemical vapor sensing and gas-phase sensor development, and has implications in both environmental safety and the detection of chemical warfare agents. Chemical Analysis for Medical Research Here at BI, our gas phase SPR techniques can also be applied by creating detectors that analyze chemical components in vapors such as human breath. Using these SPR methods could have a huge significance for a variety of health-related studies and medical research overall.
SPRm Impedance
Surface Plasmon Resonance microscopy (SPRm) Impedance measures both SPR and EIS simultaneously and is capable of imaging local electrochemical impedance in real time with high spatial resolution. This technique relies on detecting surface plasmon waves propagating on a metal thin film which are created by a laser beam incident on the metal film, typically via a prism at a resonant angle. In the same way as for EIS, an AC voltage is applied to the surface to create a surface charge density modulation (delta q), which induces a SPR signal change (delta theta). The surface plasmon resonance condition is sensitive to the dielectric constant of the metal film, which is a function of the surface charge density. Compared to SPR, the impedance signal measured by SPRm Impedance is insensitive to nonspecific binding and solution bulk index changes and because the signal scales with the surface area, it is suitable for detecting small molecules. In conclusion, by measuring SPR in an electrolyte, interfacial impedance can be measured by applying a potential modulation to the sensor surface. By measuring the amplitude and phase of the resonance angle produced by the changes in the surface charge modulation, submicron spatial resolution impedance information can be obtained to study the cellular responses dynamics or to study electrochemical reactions of nanoparticles.
Surface Plasmon Resonance (SPR) Analysis
Surface Plasmon Resonance (SPR) has emerged as a powerful detection technique due to its high sensitivity and label-free capability. This optical-based real-time detection method delivers superior results across diverse categories of research. Applications include life science, drug discovery, electrochemical analysis, food quality and safety, environmental science, and chemical sensor development. The study of molecular binding processes is a key aspect to many fields of research. From life science to environmental safety, determining which molecules interact, how they interact, and why they interact can ultimately lead to more effective drugs, higher performance materials, cleaner air/water quality, and much more. Several technologies exist that may be utilized for such molecular binding studies, i.e. ELISA, QCM, and ITC. However, few encompass as many advantages as Surface Plasmon Resonance. SPR enables (1) high sensitivity, (2) label-free detection, (3) real-time monitoring, (4) low volume sample consumption, (5) quantitative evaluation, and (6) determination of kinetic rate constants. Furthermore, SPR is easy to perform and can be a cost-effective solution.
Binding Kinetics Analysis with SPR
The five-channel BI-4500 SPR analysis system with integrated auto-sampler was used to study the binding interaction of the anti-BSA/BSA immune complex in real-time. On a CM Dextran sensor chip, different amounts of BSA were simultaneously immobilized in four channels via amine coupling. Immobilization was performed using an automated graduated injection feature of the BI SPR software package, which requires only one sample injection for the entire graduated immobilization process making immobilization simple, accurate, and sparing on sample consumption. Channels 1 through 4 were immobilized with different amounts of BSA (in the order of decreasing density) and channel 5 was left bare for reference subtraction. The ability to test interactions using multiple BSA densities strengthens the data quality by helping to identify and minimize non-ideal or secondary binding effects. Seven sets of three anti-BSA concentrations (2.5, 5.0, and 10 nM) were repeatedly exposed serially in all five channels. A regeneration injection of 20mM NaOH followed each binding interaction in order to release the anti-BSA from the immobilized BSA and expedite further testing.
Flow Injection SPR Technique (BI-DirectFlow™)
BI’S UNIQUE FLOW INJECTION SPR TECHNIQUE ALLOWS SPR ANALYSIS TO BE CARRIED OUT IN ONE CONTINUOUS STREAM. For measuring biomolecular interactions, BI’s unique Flow Injection SPR technique (BI-DirectFlow TM) delivers sample compounds with near-zero dispersion to effectively remove spurious secondary effects in measurement. This enables fast and precise kinetics for high-quality results. – BI-DirectFlow™ analysis module included in BI-4500 series – Flow Injection analysis module included with BI-2500 series Our flow injection SPR technique and high-sensitivity instruments are perfect for a variety of life science applications:
ELECTROCHEMICAL MEASUREMENTS
Our dual-measurement capability can serve as the foundation for endless creativity and originality in your research. Simultaneous electrochemical and SPR measurements, made possible by our electrochemistry SPR system, can give you additional information and new insights into various electrochemical processes. Better yet, our unique technology can open new doors in your research by helping you develop new electroanalytical and surface chemistry applications.
ENVIRONMENT, FOOD & BEYOND
The power of our tools goes well beyond the lab. The BI-SPR system is flexible for broader applications, whether it’s food safety, quality control, environmental monitoring, or the development of new high-performance SPR and coupled SPR techniques.
Modular Analysis Modules
BI’s analysis modules can easily be exchanged and configured with the instrument to expand its use into different applications such as life science, electrochemistry, chemical vapor research, and environmental safety.

Equipment & Instrumentation Manufacturers · 51–200 employees · Austria
5 listed under this category
Focus-Variation
Focus-Variation Shape & roughness measurement in one system. Focus-Variation is an optical technology which is used to perform high resolution 3D surface measurements. Its main component is a precision optics containing various lens systems that can be equipped with different objectives. It combines the small depth of focus of an optical system with vertical scanning to provide topographical and color information from the variation of focus. In other words: It delivers information about form and roughness of a surface in one go, which makes it super-efficient. Basically, Focus-Variation is applicable to surfaces with a large range of different optical reflectance values. As the optical technique is very flexible in terms of using light, typical limitations such as measuring surfaces with strongly varying reflection properties even within the same field of view can be avoided. Samples can vary from shiny to diffuse reflecting, from homogeneous to compound material and from smooth to rough surface properties. Focus-Variation overcomes the aspect of limited measurement capabilities in terms of reflectance by a combination of illumination, controlling the sensor parameters and integrated polarization. Modulated illumination means that the illumination intensity is not constant, but varying. The complex variation of the intensity can be generated by a signal generator. Through the constantly changing intensity far more information is gathered from the samples´ surface. Advanced Focus-Variation is further development of Focus-Variation to measure smooth samples. It combines the functionalities of a roughness measuring instrument and a coordinate measuring machine. Users measure workpieces with steep flanks, varying reflections and structured roughness. Advanced Focus-Variation excels in capturing high-resolution measurements of smooth, reflective and high polished surfaces. Supported by the measurement devices InfiniteFocus G6, µCMM and FocusX, Advanced Focus Variation revolutionizes precision measurement. Bruker Alicona measuring systems are based on the technology of Focus-Variation and combine the functionalities of a surface roughness measurement device and a form measurement system. Each Alicona measuring instrument is a: - surface measuring device - surface roughness measuring system - 3D measuring device for geometrical tolerancing - micro coordinate measuring system. Measuring steep flanks with angles larger than 87° is not a problem at all, and even surfaces with strongly varying reflection properties and greatly varying roughness are measurable. Focus-Variation also allows to measure smooth samples. Plus, users benefit from repeatable, robust and stable measurements. Steep flanks: Light coming from different directions is used to positively influence a measurement. The measurement of the maximum flank angle is not restricted by the numerical aperture of an objective. Depending on the surface users measure surfaces with slope angles up to 87°. True color information: Bruker Alicona´s Focus-Variation provides color information of surfaces in addition to depth information. Users receive a color image with full depth of field which is registered to the 3D points. Varying surface reflections: SmartFlash allows high resolution measurements of materials with varying surface characteristics or reflectivity. Modulated light provides optimal illumination throughout the whole measurement area. Users measure glossy, ground, rough, reflective and diffuse components. Robust against vibrations: For each measurement point Bruker Alicona systems process information not only from image points directly in the focal plane but also from areas out of focus. As focus information is utilized over a larger scan depth, the influence of vibrations on the measurement is reduced to a minimum. Users receive high resolution, traceable, and repeatable measurements even in environments with considerable vibrations. Detailed measurements: Up to 500 million measurement points ensure a meticulously detailed measurement. Measurements with tolerances in the μm and sub-μm range along with large working distance are achievable. The high measurement point density of Focus-Variation enables operators to gain a consistently high lateral and vertical resolution even across high measurement volumes. Traceable measurement of small and often hard to access radii, angles, and roughness are also possible. It’s no exaggeration to give "almost everywhere" as an answer. Focus-Variation is needed for quality assurance in production as well as research and development. The list is quite long: It is used in, e.g., tool and mold making, precision manufacturing, the aerospace and automotive industry, in all kinds of materials science, corrosion and tribology, electronics, and medical device development. Chances are very high that even today, you already used one or more components that were produced by applying Focus-Variation. The technical principle: In contrast to other optical techniques that are limited to coaxial illumination, the max. measurable slope angle is not only dependent on the numerical aperture of the objective. Focus-Variation can be used with a large range of different illumination sources (such as a ring light) which allows the measurement of slope angles exceeding 87°. With a beam splitter mirror, light emitted from a white light source is introduced into the optical path of the system and focused onto the sample via the objective. The light is reflected in several directions as soon as it hits the sample via the objective. All rays emerging from the sample and hitting the objective lens are bundled in the optics and are gathered by a light sensitive sensor behind the beam splitting mirror. To perform a complete detection of the surface with full depth of field, the precision optics is moved vertically along the optical axis while continuously capturing data from the surface. Algorithms convert the acquired sensor data into 3D information and create a true color image with full depth of field. This is achieved by analyzing the variation of focus along the vertical axis. In addition to the scanned height data, Focus-Variation also delivers a color image with full depth of field which is registered to the 3D points. This provides an optical color image which eases measurements as far as the identification and localization of measurement fields or distinctive surface features are concerned. The visual correlation between the optical color image of the samples´ surface and its depth information are often linked to each other and are therefore an essential aspect of meaningful 3D measurement. Since the described technique relies on analyzing the variation of focus it is only applicable to surfaces where the focus varies sufficiently during the vertical scanning process. Surfaces not fulfilling this requirement such as transparent samples or components with only a small local roughness are hardly measurable. Typically, Focus-Variation delivers repeatable measurement results for surfaces with a local Ra of 0.009 μm at a lc of 2 μm. Focus-Variation is used to perform high resolution 3D surface measurement for quality assurance in production as well as research and development activities in the lab. Key applications are surface analysis and characterization in e.g. tool & mold making, precision manufacturing, aerospace, automotive industry, all kinds of materials science, corrosion and tribology, electronics, medical device development. Due to its´ technical specifications the Focus-Variation technique is used for both form and roughness measurements.
Vertical Focus Probing (VFP)
Vertical Focus Probing (VFP) is based on the use of a partial light cone. Individual light rays that are diffusely reflected from vertical surfaces get captured by the lens. Flanks with more than 90° can be measured traceably, repeatably and with high resolution. Vertical flanks measured in this way can be used, e.g. for fitting of a workpiece coordinate system. Up to now, geometries such as bore holes of injection valves in the automotive industry were difficult to measure optically. The lateral probing of components with vertical surfaces was limited to tactile measuring systems, CT solutions or complex customized solutions. This changes with Vertical Focus Probing: Based on areal measurements, the optical probing of components over the entire surface is possible. Vertical Focus Probing is based on the use of partial light. In addition to coaxial light, light from different directions is used. As a result, individual light rays diffusely reflected from vertical surfaces are captured again by the objective, enabling the traceable and repeatable measurement of flanks with more than 90° in a high-resolution. How high the proportion of reflected light rays is, depends on the geometry and the roughness of the surface to be measured as well as on the light source used. The objective also plays a role, as, depending on its diameter, an objective can also capture reflected light from surfaces that show flanks steeper than 90°. This is where the numerical aperture (AN)comes into play, which is defined by the objective diameter and the working distance. It influences how much the measurable slope of a surface can still exceed the 90° mark. Vertical Focus Probing, like Focus-Variation, is based on the vertical scan of the surface to be measured. The focus information curve is evaluated for each position. The difference to Focus-Variation is that in Vertical Focus Probing not only one, but several Z-values are calculated for each measuring point (XY). These Z-values represent the vertical surface. Coordinate measuring machines are verified according to EN ISO 10360. Part of this process is, among other things, the measurement of the bidirectional length measuring error of e.g. ball bars. Typically, tactile methods are very well suited for this purpose, since they can probe the ball laterally. For optical methods this was not possible until now. With Vertical Focus Probing, this is changing: balls can be probed at the equator, which makes it possible to determine the distance. Vertical Focus Probing can be used for a wide range of applications in dimensional metrology, respectively in all areas of the manufacturing industry and production. Among others, the tooling industry, precision manufacturing, the automotive industry as well as the aerospace sector benefit from new measurement possibilities whenever it comes to components with vertical surfaces. Features such as holes, bores, reference surfaces, contours, lengths etc. can thus be optically measured with high accuracy, in high resolution and short measuring times.
Focus Probing
Focus Probing is a measurement technology for capturing accurate 3D points and 3D contours without vertical scanning. Focus Probing extracts metrically correct 3D information directly from sensor data acquired at a single position. This significantly reduces measurement time while maintaining high accuracy. Why is Focus Probing faster than conventional 3D measurement methods? Focus Probing eliminates the need for vertical scanning. Traditional technologies such as Advanced Focus-Variation or Vertical Focus Probing create area-based 3D datasets by scanning along the Z-axis. This increases measurement and processing times. Focus Probing captures relevant contour information directly, making measurements significantly faster. The measurement principle of Focus Probing is very similar to the Vertical Focus Probing. The difference is, that no vertical scanning is involved – but that 3D information is obtained from the sensor data at a single position. As with Vertical Focus Probing, Focus Probing also allows the measurement of contours at vertical walls, with the extension, that also multiple 3D contours can be measured within one field of view at once. The result: Faster measurements, shorter cycle times, and greater productivity — all while delivering the precise contour data required for demanding manufacturing applications. Application Example: Hole Distance Measurement - The contours of two laser-drilled holes are captured automatically and aligned within a 3D coordinate system. The software then calculates the exact center-to-center distance. The result is a fast, accurate, and repeatable measurement process. The advantage of Focus Probing is the fast processing time. With Focus Probing it is possible to gather high accurate 2D contours in a 3D coordinate system. Due to the efficient way of data capturing measurement time and processing times decrease heavily. This leads to faster measurements of contour based applications.
Contour Scanning
Contour Scanning is an application based on Focus Probing technology for measuring complete contours quickly and automatically - and with high precision. Contour Scanning extends the capabilities of Focus Probing by allowing users to scan longer contour paths across larger areas. The process is intuitive, automated, and optimized for maximum efficiency. Why Use Contour Scanning? Faster contour measurements; High repeatability; Automated workflows; Robust data acquisition; Easy operation; Reliable process control Contour Scanning guides users through an intuitive and automated measurement workflow. The process consists of five simple steps: 1. Define scan areas using waypoints. 2. Create the contour path directly in the live view. 3. Simulate the scan process. 4. Start the automated measurement. 5. Analyze the acquired contour data. The system automatically optimizes illumination and data acquisition along the entire scan path. Ready to experience Contour Scanning? Discover how Contour Scanning can accelerate your inspection process and improve manufacturing efficiency.
Quality Assurance for Additively Manufactured Medical Devices
Additive manufacturing, also known as 3D printing, is a modern process used to create complex and customized components. This process plays a crucial role in the manufacture of patient-specific medical devices. Here too, Bruker Alicona offers solutions to ensure the high quality of additively manufactured medical implants. Measurement technology plays an important central role in all process steps of the production chain - both in production and for the final inspection of the manufactured component. The focus here is mainly on roughness measurement. In addition, geometric features such as internal structures, different wall thicknesses, free-form surfaces or structures in very small sizes must also be verified.

Academic & Research Institutions · United States
1 listed under this category
Scanning probe microscopy
Scanning probe microscopy. Equipment rates (internal / nonprofit, $/hour): NT-MDT Solver NEXT SPM $35 / $77; NT-MDT NTegra SPM $35 / $77; NT-MDT SolverNANO SPM $35 / $77.